Lab report of Sample dust to be comply with OSHA (environment)

profilemutairht
lab_data.doc

Lab data

Fall 2016

Metler Scale

Procedure:

Students shall weigh 10 PVC filters and record the post weight of each filter. The student shall then use the following data to identify the TWA for Employee A and Employee B.

Trial

Pre Sample reading

Post reading

1

2.5071

2.4675

2

2.5082

2.4842

3

2.5036

2.4847

4

2.5036

2.4846

5

2.5048

2.4974

6

2.5026

2.4908

7

2.5001

2.4846

8

2.5119

2.4829

9

2.5114

2.4780

10

2.5071

2.4816

Employee A

Sampling pump calibration data:

Pre-Calibration – 2.5052 liters per minute

Post Calibration – 2.4638 liters per minute

Average calibration is (2.5052 L+2.4638 L)/2=2.4845 L (2.45/1000=.00248 m3

Pre-Weight

Sampling Time

Post weight

Volume

13.12 mg

480 min

15.91 mg

0.00248*480=1.19 m3

Blank X 13.39 mg

14.52 mg

· (15.91 mg-13.12 mg) – (14.52 mg-13.39)/1.19 m3 = 1.39 mg/m3

TWA=

(1.39 mg/m3*(480)/480=1.39 mg/m3

In compliance.

https://www.osha.gov/dts/chemicalsampling/data/CH_259640.html

Page 1