Lab report of Sample dust to be comply with OSHA (environment)
Lab data
Fall 2016
Metler Scale
Procedure:
Students shall weigh 10 PVC filters and record the post weight of each filter. The student shall then use the following data to identify the TWA for Employee A and Employee B.
|
Trial |
Pre Sample reading |
Post reading |
|
1 |
2.5071 |
2.4675 |
|
2 |
2.5082 |
2.4842 |
|
3 |
2.5036 |
2.4847 |
|
4 |
2.5036 |
2.4846 |
|
5 |
2.5048 |
2.4974 |
|
6 |
2.5026 |
2.4908 |
|
7 |
2.5001 |
2.4846 |
|
8 |
2.5119 |
2.4829 |
|
9 |
2.5114 |
2.4780 |
|
10 |
2.5071 |
2.4816 |
Employee A
Sampling pump calibration data:
Pre-Calibration – 2.5052 liters per minute
Post Calibration – 2.4638 liters per minute
Average calibration is (2.5052 L+2.4638 L)/2=2.4845 L (2.45/1000=.00248 m3
|
Pre-Weight |
Sampling Time |
Post weight |
Volume |
|
13.12 mg |
480 min |
15.91 mg |
0.00248*480=1.19 m3 |
|
Blank X 13.39 mg |
|
14.52 mg |
|
· (15.91 mg-13.12 mg) – (14.52 mg-13.39)/1.19 m3 = 1.39 mg/m3
TWA=
(1.39 mg/m3*(480)/480=1.39 mg/m3
In compliance.
https://www.osha.gov/dts/chemicalsampling/data/CH_259640.html