floor plan for make up shop

profilebrunette
store_planning_symbols.pdf

Retai I Store Planning & Design Manual

by

Michael J. Lopez A.s.!.D-r.s.p

nRma NATIONAL RETA! L MERCHANTS ASSOCIATTON

100 West 3lst Street, New York, N.Y. ,l000.1

Te I ephone : (21 2) 244-87 B0/Ie lex : I N T' L 2 20-88 3-TAU R

Chapter 15 LEGENDS

ln order to produce an entire set of understandable drawings the store planner must refer to a set of legends. Every store planning office will have their orun type of legends to which the entire company will adhere in order to prevent confusion.

Line legends are used to draw the building, interior walls and decor. Reflected ceiling and lighting leg- ends are symbols which are used to indicate the

direction of the ceiling grid and the types of lighting fixtures which will illuminate the interior. The power/ electrical legends indicate what type of electrical outlets, services and locations are required for the electrification of equipment. plumbing legends indi- cate water related seruice. Color legends help to indicate the finishes within the interior space and the legend of the free-standing fixtures indicates place- ment and type of equipment.

187

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

Job #- Date- LINE LEGEND Sheet

SYMBOL DESCRIPTION

Existing Building Wall

-

New Building Wall

Existing lnterior Partition / with Slatwall

fr New lnterior Partition / with Slatwall EEI Low Wall - Verify Height with Elevations

---\- Existing Wall Removal

Mezzanine Line

Curtain Wall

Single Cornice

3:=--=====--== Double Gornice

Fitting Room Partition System

Floorcovering Break Line

-ar

Aisle Center Line / Departmental Break Line

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

REFLECTED CEILING / LIGHTING LEGEND

Typical 2' x 4'ceiling grid with desiglrer,s specified lay-in ceiling

Typical 2' x 2'ceiling grid with designer,s specified lay-in ceiling

2' x 4' recessed ftuorescent framed door troffer with acrylic prismatic lens *

2' x 4' recessed fluorescent with paracube lens *

2', x 4', recessed fruo.rescent with deep ceil paraboric rens.Verify number of cells with rettecteJ-ceilino otrn 1' x 4' recessed fluorescent framed door troffer with acrylic prismatic lens *

2' x 2' recessed fluorescent with paracube lens *

Wall mounted low contrast illumination fixture with opalacrylic diffuser; length as indicated *

S.ufage.mgunted (horizontally), double lamp fluorescent strip lioht *

S.ufage.mgunted (horizontalty), singte tamp ftuorescent strip lioht *

Surface mounted (vertically) fluorescent strip light *

Surface mounted track with track mount convertor fixture

Recessed track with track mount convertor fixture

Becessed incandescent downlight; to include flood lampand bar hanoers

LEGEND

!1Ol'r19 to inctude energy saving bailast

and.fluorescent tube lamps as required designer's specif ications.

189

by

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

Lights to include energy saving ballast and fluorescent tube lamps as required by designer's specif ications. With directional arrows as indicated on plan.

REFLECTED CEILING / LIGHTING LEGEND Job #- Date-

Sheet

SYMBOL DESCRIPTION

6 Recessed, adjustable, incandescent, accent light; to include spot lamp and bar hangers.

o, Recessed, adjustable, incandescent accent light; to include flood lamp and bar hangers.

o Shallow recessed downlight furnished with bar hangers. * Ceiling outlet for chandelier light to be determined by owner's choice

-l

Standard lndustrial double lamp fluorescent fixture *

a Exit sign with Battery Standby, stencil face type, red on white, dual voltage, universal mount **

ffi Open cell (1/2" x Vz" x Vz") plaStiC eggCrate

190

**

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

POWER / ELECTR]CAL LEGEND Job #_ Date_ Sheet

SYMBOL DESCRIPTION

o I Floor Outlet; 110V with ground I

I

I Wall Outlet; 110V with ground I

I

I Duplex Wall Outlet; 110V with ground I

I Outlet by Fixture Contractor; with ground (mounted as part of fixture) Duplex Outlet by Fixture Contractor; with ground (mounted as part of fixture)

Communication Ouilet

Junction box; floor mounted

Junction box; mounted above ceiling

Junction box; wall mounted

Junction box by t (mounted as part of fixture)

Telephone Ouilet

Cash Register

+ €=

-1--?--

o o 6 @{

(!.)

A $

$8< Cash and Wrap Location Horizontally rorn," Mount as indicated above finished floor.

{+t+t+{+

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

POWER / ELECTRICAL LEGEND Job #- Date-

Sheet

SYMBOL DESCRIPTION

+ Vertically Mounted Plugmold

@ Antenna Floor Outlet

@, Antenna Wall Outlet

E Vertically Mounted Antenna Track

Horizontally Mounted Antenna Track

+ Ceiling Mounted Clock @' Wall Mounted Clock

tr Security System Device AFF Above Finished Floor

FM Antenna used for radios

P Public Pay Telephone

TV Antenna used for Television (VHF & UHF)

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

PLUMBING LEGEND

Water Heater; See plans for Specifications

Waste Drain with Vent

Hot Water Suppty

Cold Water Suppty

Electrical Water Fountain

Sink; See Plans for Specifications

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

COLOR LEGEND Job #- Date_

Sheet

SYMBOL DESCRIPTION

u Paint A Golored Lacquer o Wallcovering o High Pressure Laminate

Special Finish

o Floorcovering

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

LEGEND OF FREE STANDING STORE FIXTURES Job #_ Date-

Sheet

SYMBOL DESCRIPTION

DtvtstoN 001-099 sHowcAsEs AND AccEssORrES

001-039 Showcases and Fills

040-059 Back lslands and Fills

060-079 Cash and Wraps and Miscellaneous

tr 080-099 Miscellaneous Fixtures DIVISION 100.199 HIGH PRESSURE LAMTNATE CASE WORK

100-109 Drawered Tables / Variations

o 110-119 Display Platforms / Variations 120-139 Tables / Variations

o 140-149 Round Tables / Variations 150-159 Desks

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

LEGEND OF FREE STANDING STORE FIXTURES Job #- Date-

Sheet

SYMBOL DESCRIPTION

160-1 79 M iscellaneous Fixtures

180-199 Bases with Risers

DIVISION 200.299 GONDOLAS, SUPERSTRUCTURES, AND FRAMES

DIVISION 300.399 GLASS CUBE ASSEMBLIES

DIVISION 400.499 CASH AND WRAPS AND SERVICE COUNTERS

DIVISION 500.599 MISCELLANEOUS CUSTOM FTXTURES

500-549 Custom Designed Fixtures

550-599 Manufacturer's Fixtures (See Accessory Spec)

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

LEGEND OF FREE STANDING STORE FIXTURES Job #- Date-

Sheet

SYMBOL DESCRIPTION

DIVISION 600.699 GARMENT AND VENDOR RACKS

600-649 Garment Flacks (See Rack Legend)

r---- --l ;l rl L-----J

650-699 Vendor Racks (Verify Size)

DIVISION 700.799 PERIMETER CASEWORK

DIVISION 800.899 REFURBISHED EXISTING FIXTURES

DrvrstoN 900-999 FITTING ROOMS

Store Name Store # Store Location Completion Date Job Telephone

Store Planner Address City, State Telephone

RACK LEGEND Job #- Date-

Sheet

SYMBOL DESCRIPTION

@ 36" Round Rack

@ 36" Three Level Rack

36" x 60" Straight Rack

36" x 60" 6-Way Rack

4-Way Rack with 21" Arms

.H 4-Way Rack with 16" Arms

B 30" T-Stand # 24" x 24" Pronged Rack