Ergonomics

profileabdl.h
lab1result_sep242014_2.docx

IE 665

EMG Laboratory results:

Figure 1. Graph of EMG in millivolt (blue) of biceps muscle measured at 1000 samples/sec, and hand forces (red) in kg recorded from the load cell at 100 samples/sec from Participant#1.

Figure 2. Graph of raw EMG in millivolt (blue) of biceps muscle measured at 1000 samples/sec, and hand forces (red) in kg recorded from the load cell at 100 samples/sec from Participant#2.

Table 1. Maximum force in kg and corresponding EMG in mv for each exertion for the two participants

Exertion #

Participant#1

Participant#2

Force

EMG

Force

EMG

1

11.58

0.31

5.43

0.06

2

9.12

0.27

5.58

0.09

3

16.64

0.47

6.30

0.07

4

4.79

0.17

6.46

0.10

5

5.76

0.18

6.65

0.09

6

7.00

0.22

6.65

0.09

7

7.51

0.22

6.70

0.10

8

7.25

0.19

8.35

0.12

9

7.90

0.23

14.50

0.26

10

7.40

0.19

15.00

0.25

P100/P200 2

0:00.000 0:05.000 0:10.000 0:15.000 0:20.000 0:25.000 0:30.000 0:35.000 0:40.000

22.68

-22.68

-10

(Kg) 0

10

P100/P200 2

0:00.000 0:05.000 0:10.000 0:15.000 0:20.000 0:25.000 0:30.000 0:35.000 0:40.000

22.68

-22.68

-10

(Kg) 0

10