| Site Information | | | | CDs | | | | Structural | | | | | | | | | | | | | Samsung BOM | | | | | | | | | | Scoping | | | | | GD BOMs | | | | | | | | | | | | | | | Notes | AC Panels | | | Construction |
| Cascade # | Site Name | Task # | NTP Dates | SAMs | 90% Review Completed | CD Uploaded for Review | AE Vendors | Tower & Equipment Structural Recv. | Structural Completed | Date Reviewed | Approved | Notes | Mount Structural Recv. | Mount Analysis Completed | Date Reviewed | Approved | Notes | Letter Approval Needed | Notes | CM review | State | Cabinet Type | Alpha | Beta | Gamma | Delta | Completion Date | Submitted Date | Revised Date | Notes | CM Name | Review Date | Site Type | Submit Date | Approved Date | CM Name | Sector Count | Rad Center | Tower Type | Ant# | RRU # | RET Cable # | Indoor/Outdoor | Eqpt Type | Platform Style | Complete Date | Submit Date | Approved Date | Ordered Date | Received Date | Notes | AC Panel | Power Upgrade | Need Sub Panel | CM | CS | Site Walk | Pre-Con Walk | CNX Start | 594 Complete | Special Notes |
| DE05AL522 | Green River East | H142 | 5/25/13 | Lane | 1/25/13 | | Fullerton | Yes | 1/23/13 | 5/20/13 | Approved | Letter is going to be provided to show everything will be cleared. | Yes | n/a | 5/20/13 | Approved | Letter will be provided to show everything is cleared. | Yes | Cleared | Nick | Utah | Outdoor | 180 | 180 | 180 | n/a | 1/2/13 | 1/2/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 150' | Monopole | 3 | 6 | 3 | O | O | Concrete Pad | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Daren Holt | Steve Mann | | | 5/30/13 |
| SL03UB103 | Ubiquitel-Dry Canyon | H149 | 3/12/13 | Lane | 2/12/13 | | TAIC | Yes | n/a | 4/29/13 | Rejected | Structural was ran for the 2 existing mounts, not the third that we are adding. | Yes | 2/12/13 | 5/14/13 | Rejected | MA was ran for installing the Hy-Cap site in a two step and we are putting all the antennas and RRUS up at one time. Also the MA doesn't spec the mount that is to be used on the Lam pole, antenna weights are not correct b/c we have 2 different styles. MA also shows Monopole and Self Support tower and this is a Lam | Yes | (Nick’s reply - I see it in the top notes two antennas and 3 RRUs, but in the calculations part, it states how many antennas per mount, and 1 was put in and the same with the RRUs. So the correct weight is not showing on this document. Total weight should be 347 lbs. not 201 lbs. as it shows.) | Nick | Utah | Outdoor | 75H | 75H | 75H | n/a | 1/10/13 | 1/10/13 | | | Mary | | Tower | | | Nick | 3 | 30' | Wooden Pole | 6 | 9 | 8 | O | O | Steel Platform | | | | | | Hy-Cap site and need to verify if tower will be able to hold the additional mount and weight. | 200 A | N | N | Jacob Walker | n/a | | | 4/12/13 |
| SL03UB104 | Downtown Logan | H150 | 4/6/13 | Lane | 2/7/13 | | TAIC | Yes | n/a | 4/29/13 | Approved | n/a | Yes | n/a | 4/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 150H | 150H | 150H | n/a | 1/10/13 | 1/10/13 | | | Mary | | Tower | | | Nick | 3 | 76' | Self Support | 6 | 9 | 6 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | Need to order 3 additional NV antennas | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/7/13 |
| SL03UB106 | Crow Mountain | H151 | 7/10/13 | Lane | 2/14/13 | | TAIC | No | n/a | 5/29/13 | n/a | No Structural Analysis at this time | Yes | 4/15/13 | 5/29/13 | n/a | Need Rad Center verification from RF | No | Need SA approved and RF verify. | Nick | Utah | Outdoor | 90H | 90H | 90H | n/a | 1/10/13 | 1/10/13 | | sent back to Mary, not showing additional 2 cabinets | Mary | | Tower | | | Nick | 3 | 40'/50' | Wooden Pole | 6 | 9 | 6 | O | S/O | Steel Platform | | | | | | Sent Back to Mary. Hy-Cap Site is not going to work for what is shown. | 200 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03UB110 | Ubiquitel Hyrum | H152 | 3/30/13 | Lane | 2/12/13 | | TAIC | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | Hot Slide not needed | Nick | Utah | Outdoor | 180 | 180 | 180 | n/a | 1/10/13 | 1/10/13 | | | Mary | | Tower | | | Nick | 3 | 105' | Monopole | 3 | 6 | 3 | I | O | Shelter w/ Concrete floor | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 4/24/13 |
| SL03UB111 | Silage | H010 | 3/6/13 | Lane | 3/13/13 | | Caltrop | Yes | 12/5/12 | 5/14/13 | Approved | Failed at Inerim at the base at 150.9%, but Passes at Final at 100.8% | Yes | 2/4/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 120 | 120 | 120 | n/a | 1/10/13 | 1/10/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 103' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 200 A | N | N | Jacob Walker | Clay Schutzer |
| SL03UB113 | Ubiquitel Brigham | H153 | 5/25/13 | Lane | 2/20/13 | | WT | Yes | 12/20/12 | 6/11/13 | Approved | n/a | Yes | 6/21/13 | 6/21/13 | Approved | n/a | No | n/a | Group | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/2/13 | 1/2/13 | 6/11/13 | | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Jacob Walker | n/a |
| SL03UB116 | Ubiquitel - Tremonton - UT | H154 | 3/9/13 | Lane | 1/25/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | 5/30/13 | 6/11/13 | Approved | MA has been corrected and uploaded to Siterra. | No | MA is corrected and approved | Nick | Utah | Outdoor | 195 | 195 | 195 | n/a | 1/10/13 | 1/10/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 154' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 100 A | N | N | Jacob Walker | n/a | | | 4/16/13 |
| SL03UB120 | Preston | H156 | 5/29/13 | Lane | 2/8/13 | | TAIC | No | n/a | 5/29/13 | n/a | No Structural Analysis at this time | Yes | 4/8/13 | 5/29/13 | Approved | n/a | No | install standoff mount off the existing mount. | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/10/13 | 1/10/13 | | | Mary | | Tower | | | Nick | 3 | 87' | Wooden Pole | 3 | 6 | 3 | O | S/O | Steel Platform | | | | | | Sent back to Mary to verify | 200 A | N | Y | Jacob Walker | n/a | | | | | Install 3' standoff mount. |
| SL03UB130 | Ubiquitel S&S Fun Center | H158 | 3/19/13 | Lane | 1/30/13 | | TAIC | No | n/a | 5/14/13 | n/a | No Structural ran so far | Yes | 2/20/13 | 5/10/13 | Approved | 4 Sector Mount to be installed | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/10/13 | 1/10/13 | | | Mary | | Tower | | | Nick | 3 | 80' | Wooden Pole | 3 | 6 | 3 | O | S/O | Shelter inside Tower | | | | | | sent to Mary to look at | 100 A | N | Y | Jacob Walker | n/a |
| SL03UB131 | Ubiquitel - Riverside Cornwall | H159 | 3/21/13 | Lane | | | TAIC | Yes | n/a | 4/30/13 | Rejected | “Wooden Pole” - Mount analysis was ran for “Monopole” - doesn’t specify new mount or type - No Structural ran on Wooden Pole - CD states Monopole on the very first page. Platform Structural was ran for a Hot Swap. | Yes | n/a | 4/30/13 | Rejected | “Wooden Pole” - Mount analysis was ran for “Monopole” - doesn’t specify new mount or type - No Structural ran on Wooden Pole - CD states Monopole on the very first page. Platform Structural was ran for a Hot Swap. | Yes | (Nick’s reply - Long as a Certified Letter is provided stating the Interim is good with everything on the mount, than this will be sufficient but we must have the Letter First, before Construction can begin.) | Nick | Utah | Outdoor | 90 | 90 | 90 | n/a | 1/10/13 | 1/10/13 | | Sent back this is a Wooden Pole, not a Monopole | Mary | | Tower | | | Nick | 3 | 47' | Wooden Pole | 3 | 6 | 3 | O | S/O | Steel Platform | | | | | | sent to Mary to look at | 100 A | N | N | Jacob Walker | n/a | | | 4/17/13 |
| SL03UB401 | Mona | H160 | 3/5/13 | Lane | 2/6/13 | | Smith Hyatt | Yes | n/a | 4/30/13 | Approved | Tower Structural was ran correctly, no standoff mount for Gamma, install it on the leg of the tower and the other two sectors will be placed on the existing mounts. | Yes | 5/24/13 | 5/24/13 | Approved | Mount analysis was ran for installing 2 antennas and 4 RRUs on the two existing mounts and Gamma antenna and 2 RRUs will be mounted on the back of the antenna on the leg. | No | n/a | Nick | Utah | Outdoor | 255 | 255 | 255 | n/a | 1/10/13 | 1/10/13 | | | Mary | | Tower | | | Nick | 3 | 192' | Self Support | 3 | 6 | 5 | O | O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 4/10/13 |
| SL03UB414 | Ubiquitel UT003 Exit 112 | H014 | 3/30/13 | Lane | 3/14/13 | | Caltrop | Yes | n/a | 5/17/13 | Approved | Fails Structural at Interim at 133%, but passes at Final at 100.6% - need to remove the existing pipe mounts. | Yes | n/a | 5/17/13 | Approved | remove exiting Pipe mounts | No | n/a | Nick | Utah | Outdoor | 285 | 285 | n/a | n/a | 1/10/13 | 1/10/13 | 3/28/13 | | Mary | | Tower | | | Nick | 2 | 251' | Self Support | 2 | 4 | 4 | O | O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 5/23/13 |
| SL03UB419 | Jones-Enoch | H163 | 3/31/13 | Lane | 2/11/13 | | Smith Hyatt | Yes | 2/28/13 | 5/6/13 | Approved | n/a | Yes | 5/30/13 | 5/31/13 | Approved | MA was corrected and showing the 6 RRUs | Yes | MA was corrected and provided | Nick | Utah | Outdoor | 240 | 240 | 240 | n/a | 1/11/13 | 1/11/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 190' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 5/15/13 |
| SL03UB420 | Ceader City State Lands | H164 | 4/6/13 | Lane | 2/27/13 | | Smith Hyatt | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 150 | 135 | n/a | 1/11/13 | 1/11/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 75' | Self Support | 3 | 6 | 4 | O | O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL03UB421 | Ubiquitel Kanarraville | H165 | 5/2/13 | Lane | 2/8/13 | | Smith Hyatt | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Approved | Needs Hand rails | No | n/a | Nick | Utah | Single Outdoor | 180 | 180 | n/a | n/a | 1/11/13 | 1/11/13 | 3/29/13 | | Mary | | Tower | | | Nick | 2 | 120' | Self Support | 2 | 4 | 4 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL03UB425 | Harrisburg Junction | H167 | 2/21/13 | Lane | 1/30/13 | | Smith Hyatt | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 240 | 240 | 240 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | | Mary | | Tower | | | Nick | 3 | 190' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 200 A | N | Y | Daren Holt | n/a | | | 4/9/13 |
| SL03UB426 | Ubiquitel Washington | H168 | 5/28/13 | Lane | | | Smith Hyatt | Yes | 4/22/13 | 6/11/13 | Approved | n/a | No | n/a | 6/11/13 | n/a | No MA provided at this time | No | n/a | Group | Utah | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Jerry Tweden | Jerry Tweden |
| SL03UB427 | Ubiquitel Rococo | H169 | 4/10/13 | Lane | | | Smith Hyatt | Yes | 5/31/13 | 6/3/13 | Approved | SA has been corrected. Install 3 Cantilever mounts and have 3 existing antennas standing off the existing mount. | Yes | 5/31/13 | 6/3/13 | Approved | MA has been corrected and reflects what is shown in the CD. | No | MA and SA are corrected and reflect the CD. | Nick | Utah | Single Outdoor | 60H | 60H | 90H | n/a | 1/11/13 | 1/11/13 | | | Mary | | Tower | | | Nick | 3 | | Rooftop | 6 | 9 | 6 | O | S/O | Steel Platform | 6/20/13 | 6/20/13 | | | | Coax will need to be painted | 200 A | N | Y | Daren Holt | Steve Mann |
| SL03UB428 | Ubiquitel Santa Clara | H170 | 6/1/13 | Lane | | | Smith Hyatt | Yes | 6/7/13 | 6/11/13 | Approved | SA has been corrected and approved | Yes | 6/7/13 | 6/11/13 | Approved | MA has been corrected and approved | No | n/a | Nick | Utah | Single Outdoor | 150H | 150H | 150H | n/a | 1/11/13 | 1/11/13 | | | Mary | | Tower | | | Nick | 3 | 70' | Monopole | 6 | 9 | 6 | O | S/O | Steel Platform | 6/15/13 | 6/16/13 | | | | installing 12' 6" Mount, need to install conduit about 45', also need to paint mounts, hybrid cables, and antennas. | 200 A | N | Y | Daren Holt | n/a |
| SL03UB429 | Webb Hill | H171 | 4/26/13 | Lane | 2/21/13 | | Smith Hyatt | Yes | 1/24/13 | 6/7/13 | Rejected | SA states mount is at 43' and RAD Center is 50'. Plus it was ran for 6 hybrid cables instead of 3. | Yes | 6/18/13 | 6/21/13 | Approved | Provide 2" std pipe with plates and ubolts to tie the end of the frame back to the tower. This will provide a point to resist rotation of the antenna support frame. Recommend adding a brace from the end of mount frame to Tower. Brace willforma triangle w/ mount frame, face of tower, and the brace. | Yes | Need to have the SA verify RAD Center and correct the MA. | Nick | Utah | Single Outdoor | 120H | 120H | 120H | n/a | 1/11/13 | 1/11/13 | | Provide 2" std pipe with plates and ubolts to tie the end of the frame back to the tower. This will provide a point to resist rotation of the antenna support frame. Recommend adding a brace from the end of mount frame to Tower. Brace willforma triangle w/ mount frame, face of tower, and the brace. | Mary | | Tower | | | Nick | 3 | 55' | Self Support | 6 | 9 | 6 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/15/13 | | Provide 2" std pipe with plates and ubolts to tie the end of the frame back to the tower. This will provide a point to resist rotation of the antenna support frame. Recommend adding a brace from the end of mount frame to Tower. Brace willforma triangle w/ mount frame, face of tower, and the brace. |
| SL03UB430 | Ubiquitel Santaquin | H172 | 3/30/13 | Lane | 1/9/13 | | Fullerton | Yes | 1/23/13 | 6/11/13 | Rejected | SA was ran for the existing mount, didn't run for the new 12' mount that is called out in the CD, MA specifiies new mount. | Yes | 1/31/13 | 6/11/13 | Rejected | the end of the frame back to the tower. This will provide a point to resist rotation of the antenna support frame. | No | n/a | Group | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/2/13 | 1/2/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 94' | Monopole | 3 | 6 | 3 | O | S/O | Concrete Pad | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL03UB450 | Ubiquitel-Nephi | H173 | 3/7/13 | Lane | 1/14/13 | | Smith Hyatt | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 165 | 165 | 165 | n/a | 12/31/12 | 12/31/12 | 3/25/13 | No possible dual install, small platform | Mary | | Tower | | | Nick | 3 | 135' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 4/29/13 |
| SL03UB471 | Ubiquitel Red Cliffs | H174 | 4/23/13 | Lane | | | Smith Hyatt | No | n/a | 5/29/13 | n/a | No Structural Analysis at this time | No | n/a | 5/29/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 105H | 105H | 105H | n/a | 1/11/13 | 1/11/13 | | | Mary | | Tower | | | Nick | 3 | | Wooden Pole | 6 | 9 | 6 | | | | | | | | | | | | | Daren Holt | n/a |
| SL03UB472 | Hurricane Rim | H175 | 5/2/13 | Lane | | | Smith Hyatt | Yes | 4/24/13 | 6/11/13 | Rejected | SA - Needs to specify weight and size of mount used in the calculations in the SA. - PE will be accepted | No | n/a | 6/11/13 | n/a | No MA provided at this time | Yes | PE letter stating for mount calculations used in SA | Group | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jerry Tweden | Jerry Tweden |
| SL03UB474 | Ubiquitel Rockville | H176 | 5/16/13 | Lane | | | Smith Hyatt | Yes | 3/27/13 | 6/17/13 | Approved | Need verification on RAD Center, SA state 70' and the CD states 77' - Verified and approved. | Yes | 3/27/13 | 6/11/13 | Approved | n/a | Yes | CD needs to be corrected to show the RAD Center at 73'' | Emily | Utah | | | | | | | | | | | | | | | Nick | 2 | | Self Support | 4 | 4 | 4 | | | | | | | | | | | | | Daren Holt | n/a |
| SL03UB480 | Ubiquitel Ivins | H178 | 4/29/13 | Lane | | 2/24/13 | Smith Hyatt | Yes | 4/24/13 | 6/11/13 | Rejected | Need letter. CD calls for powerwave attenna on Gamma. SA lists 3 KMW attennas. Need letter saying powerwave will not create any structural or mount analysis issues. | Yes | 6/21/13 | 6/21/13 | Approved | n/a | Yes | PE letter stating powerwave will not create any structural or mount analysis issues. | Dez | Utah | Single Outdoor | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03UB481 | Ubiquitel Fiddlers Canyon | H179 | 6/4/13 | Lane | | | Smith Hyatt | Yes | 4/22/13 | 6/11/13 | Approved | n/a | Yes | 6/19/13 | 6/19/13 | Approved | n/a | No | n/a | Craig | Utah | | | | | | | | | | Mary | | | | | | | 85' | Self Support | | | | | | | | | | | | | | | | Jerry Tweden | Jerry Tweden |
| SL03UB500 | Payette Bluff | G019 | 3/30/13 | Lane | 2/18/13 | | TAIC | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | Mount analysis was ran for more than what's currently on the mount. | No | n/a | Nick | Idaho | Single Outdoor | 195 | 195 | 195 | n/a | 1/3/13 | 1/3/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 140' | Self Support | 3 | 6 | 3 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | Need to paint coax Red and White | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/29/13 |
| SL03UB503 | Ubiquitel Payette Co Sheriff | G020 | 4/17/13 | Lane | 2/19/13 | | TAIC | Yes | n/a | 5/7/13 | Rejected | a Tower Mapping was uploaded as a Structural, nothing is mentioned of the new Equipment going on the Tower | Yes | n/a | 5/14/13 | Rejected | Mount analysis was ran at 87' and our mount is at 100'. Need to be redone. - New mount analysis was ordered 5/14/13 | No | n/a | Nick | Idaho | Single Outdoor | 165 | 165 | 165 | n/a | 1/3/13 | 1/3/13 | 4/23/13 | | Mary | | Tower | | | Nick | 3 | 100' | Self Support | 3 | 6 | 3 | OD | S/O | Steel Platform | 4/23/13 | 4/23/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. |
| SL03UB504 | Ubiquitel Langley Gulch | G021 | 3/30/13 | Lane | 1/19/13 | | TAIC | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 300 | 300 | 300 | n/a | 1/4/13 | 1/4/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 250' | Self Support | 3 | 6 | 3 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/8/13 |
| SL03UB505 | Ubiquitel - Parma ATC | G022 | 3/30/13 | Lane | 2/18/13 | | TAIC | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | n/a | 135 | 135 | n/a | 1/4/13 | 1/4/13 | 3/27/13 | Shelter has no Ventalation | Mary | | Tower | | | Nick | 2 | 50' | Self Support | 2 | 4 | 2 | I | O | Shelter | 3/27/13 | 3/27/13 | | | | | 200 A | N | N | Jacob Walker | n/a | | | 4/23/13 |
| SL03UB506 | Rookstool Corner | G023 | 3/30/13 | Lane | 2/12/13 | | TAIC | Yes | 1/18/13 | 5/13/13 | Approved | n/a | Yes | 3/26/13 | 5/13/13 | Approved | Letter needs to be signed on the Stamp | Yes | Stamp needs to be signed and dated | Nick | Idaho | Outdoor | 315 | 315 | 315 | n/a | 1/4/13 | 1/4/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 270' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/15/13 |
| SL03UB508 | Ubiquitel Emmett | G024 | 5/13/13 | Lane | 2/7/13 | | WT | Yes | n/a | 5/7/13 | Approved | n/a | Yes | 2/14/13 | 5/21/13 | Rejected | Mount Analysis was ran on the wrong Mount. We are at 117' not at 125' that the mount was ran at. | No | n/a | Nick | Idaho | Single Outdoor | 165 | 165 | 165 | n/a | 1/3/13 | 1/3/13 | 5/2/13 | | Daren | | Tower | | | Nick | 3 | 117' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/2/13 | 5/2/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. | | | | | Bird Nest on the Tower. Site on Hold |
| SL03UB510 | Ubiquitel Christian Gulch | G025 | 3/27/13 | Lane | 2/21/13 | | TAIC | Yes | 12/11/13 | 5/13/13 | Rejected | Structural says 188' CD shows 200' Need verifications | Yes | 4/22/13 | 5/13/13 | Rejected | Mount analysis says everything is good, but it was ran off both CD and Structural and they both disagree. | Yes | See notes in Mount and Structural | Nick | Idaho | Single Outdoor | 240 | 240 | 240 | n/a | 1/4/13 | 1/4/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 200' | Guyed | 3 | 6 | 3 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | Need to paint coax Red and White | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL03UB511 | Purple Sage | G026 | 4/24/13 | Lane | 3/29/13 | | TAIC | Yes | 3/4/13 | 6/11/13 | Approved | No microwave on CDs. Install lines beside existing cables | No | n/a | 6/11/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Craig | Idaho | Outdoor | 285 | 285 | 285 | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | 210' | Self Support | 3 | 6 | 3 | OD | O | Steel Platform | 4/23/13 | 4/23/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. |
| SL03UB512 | Ubiquitel Sommers | G027 | 7/1/13 | Lane | | n/a | TAIC | Yes | 3/11/13 | 6/11/13 | Approved | n/a | No | n/a | 6/11/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Idaho | Outdoor | 255 | 270 | 270 | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | | Self Support | 3 | 6 | 3 | O | O | | | | | | | | | | | Jacob Walker | Shane M. |
| SL03UB514 | Ubiquitel - Van Slyke Farms | G029 | 3/1/13 | Lane | 1/24/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 240 | 240 | 240 | n/a | 1/13/13 | 1/3/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 190' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 3/29/13 |
| SL03UB515 | Ubiquitel - Weitz | G030 | 2/21/13 | Lane | 1/8/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 240 | 240 | 240 | n/a | 1/4/13 | 1/4/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 190' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. | | | 3/29/13 |
| SL03UB516 | Ubiquitel Main St. | G031 | 4/10/13 | Lane | 3/29/13 | | TAIC | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 135H | 135H | 135H | n/a | 1/4/13 | 1/4/13 | 4/18/13 | | Mary | | Tower | | | Nick | 3 | 106' | Monopole | 6 | 9 | 6 | O | 2 - S/O | Steel Platform | 5/1/13 | 5/1/13 | | | | | 200A | N | N | Jacob Walker | n/a | | | 4/22/13 |
| SL03UB517 | Deer Flat | G032 | 4/24/13 | Lane | 3/29/13 | | TAIC | Yes | 3/1/13 | 6/11/13 | Approved | n/a | No | n/a | 6/11/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Emily | Idaho | Single Outdoor | 225H | 225H | 240H | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | | Self Support | 6 | 9 | 6 | OD | S/O | Steel Platform | 4/24/13 | 4/24/13 | | | | | 200 A | N | Y | Jacob Walker | n/a |
| SL03UB518 | Ubiquitel Sugar Factory | G033 | 4/24/13 | Lane | 3/29/13 | | TAIC | Yes | 4/1/13 | 6/3/13 | Approved | n/a | Yes | 4/1/13 | 6/3/13 | Approved | n/a | No | Received letter on 6/03/13 stating the SA is completed and good. | Nick | Idaho | Single Outdoor | 180H | 180H | 180H | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | 110' | Monopole | 6 | 9 | 6 | O | S/O | Steel Platform | 5/3/13 | 5/3/13 | | | | | 200 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03UB519 | Ubiquitel Town Square | G034 | 4/9/13 | Lane | 3/29/13 | | TAIC | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | CD not showing the correct mount that is on the tower. | Nick | Idaho | Single Outdoor | 120H | 120H | 120H | n/a | 1/14/13 | 1/14/13 | 5/1/13 | | Mary | | Tower | | | Nick | 3 | 85' | Monopole | 6 | 9 | 6 | O | S/O | Steel Platform | 5/1/13 | 5/1/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. |
| SL03UB520 | White Town | G035 | 3/5/13 | Lane | 1/31/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | 5/23/13 | 6/11/13 | Approved | MA is corrected & approved. | No | MA is corrected and approved | Nick | Idaho | Outdoor | 240 | 240 | 240 | n/a | 1/4/13 | 1/4/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 187' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 200 A | N | N | Jacob Walker | n/a | | | 4/12/13 |
| SL03UB521 | Ubiquitel McRae | G036 | 5/17/13 | Lane | | | TAIC | Yes | 4/9/13 | 6/12/13 | Approved | n/a | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Emily | Idaho | Outdoor | 180H | 180H | 180H | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | | Monopole | 6 | 9 | 6 | O | O | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB522 | Ubiquitel McMillian | G037 | 5/6/13 | | | | TAIC | Yes | 3/27/13 | 6/13/13 | Rejected | SA does not match CD, SA needs to show calcualtions for 6 antenas instead of 3. | Yes | 4/1/13 | 6/13/12 | Rejected | Letter needed to show how many atennas and RRUs were used in the MA | Yes | No owner approved CD uploaded to Siterra | Emily | Idaho | Single Outdoor | 330H | 330H | 330H | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | 200' | Guyed | 6 | 9 | 6 | O | S/O | Steel Platform | 5/3/13 | 5/3/13 | | | | Coax will need to be painted | 200 A | N | Y | Jacob Walker | n/a |
| SL03UB523 | Ubiquitel Glenwood | G038 | 4/114/13 | Lane | 1/31/13 | | TAIC | Yes | n/a | 5/8/13 | Approved | Hy-Cap Site | Yes | n/a | 5/14/13 | Rejected | Mount analysis was ran off the CD and the CD was done for a regular 3 antennas and 6 RRHs. There are a total of 6 antennas and 9 RRUs going on the tower. Letter is not stamped or Signed - Approved - Rejected - new mount analysis ordered 5/14/13 | Yes | Need mount analysis redone and have it signed and dated | Nick | Idaho | Single Outdoor | 165H | 165H | 165H | n/a | 1/4/13 | 1/4/13 | 4/17/13 | Given back to STA - 2 MMMBS and 2 BBUs - Not enough room | Mary | | | | | Nick | 3 | 110' | Monopole | 6 | 9 | 6 | O | 2 - S/O | Steel Platform | 4/17/13 | 4/17/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 6/7/13 |
| SL03UB524 | State & Dewey | G039 | 3/19/13 | Lane | 2/8/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 90 | 90 | 90 | n/a | 1/14/13 | 1/14/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 50' | Monopole | 3 | 6 | 3 | O | S/O | Concrete Pad w/ Steal Platform | 3/26/13 | 3/26/13 | | | | | 200 A | N | N | Jacob Walker | n/a | | | 4/9/13 |
| SL03UB526 | Idaho Power Downtown | G040 | 7/3/13 | Lane | | | TAIC | Yes | 5/15/13 | 6/12/13 | Rejected | Calculations need to be shown for high capacitiy and for stand off mounts. | Yes | 5/15/13 | 6/12/13 | Rejected | Calculations need to be shown for high capacitiy and for stand off mounts. | No | n/a | Emily | Idaho | Single Indoor | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Site Walk Needed | | | | Jacob Walker | n/a |
| SL03UB527 | Ubiquitel Choctaw | G041 | 6/19/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | No SA has been provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB528 | Ubiquitel Jack's Tire & Oil | G042 | n/a | Lane | | | ERROR:#N/A | Yes | n/a | 6/12/13 | n/a | Need site photos to verify SA | Yes | n/a | 6/12/13 | n/a | Site walk needed | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Site Walk Needed | | | | n/a | n/a |
| SL03UB529 | Black Creek | G043 | 6/23/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | No SA has been provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB531 | Ubiquitel Ditto Creek | G044 | 6/14/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | No SA has been provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB533 | Ubiquitel Shell Station | G045 | 6/17/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | No SA has been provided at this time | Yes | 4/23/13 | 6/11/13 | Rejected | The MA doesn't identify the interim dual position mount and it's calculation, and than it doesn't indetify the single mount that it will change to at final. Also the collar weight is never mention. This needs to be corrected and provided. | Yes | MA needs to have the correct configuration. | Nick | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a | | | 5/14/13 |
| SL03UB534 | Ubiquitel Rocky Butte | G046 | 7/5/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | No SA has been provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB535 | Mt. Home AFB | G047 | 3/30/13 | Lane | 1/28/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 120 | 120 | 120 | n/a | 1/14/13 | 1/14/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 70' | Self Support | 3 | 6 | 4 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/9/13 |
| SL03UB536 | Hammett ATC | G048 | 3/28/13 | Lane | 2/4/13 | | TAIC | Yes | 1/24/13 | 6/13/13 | Approved | Coax needs to be double stacked | Yes | 3/26/13 | 6/13/13 | Rejected | Letter needed to show how many atennas and RRUs were used in the MA | Yes | Letter is neeed to show the number of antennas and RRUs were used in the calculations. | Emily | Idaho | Single Outdoor | 345 | n/a | 345 | n/a | 1/14/13 | 1/14/13 | 3/27/13 | | Mary | | Tower | | | Nick | 2 | 290' | Guyed | 2 | 4 | 3 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/9/13 |
| SL03UB538 | Ubiquitel Rocky Trail | G049 | 3/31/13 | Lane | 2/6/13 | | TAIC | Yes | 3/17/13 | 5/13/13 | Approved | n/a | Yes | 4/3/13 | 5/15/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 345 | 345 | 345 | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | 281' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL03UB540 | Ubiquitel Jerome West | G050 | 4/9/13 | Lane | 3/28/13 | | TAIC | Yes | 1/24/13 | 5/13/13 | Approved | n/a | Yes | 4/2/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | n/a | 255 | 255 | n/a | 1/14/13 | 1/14/13 | 4/17/13 | Given back to STA | Mary | | Tower | | | Nick | 2 | 200' | Self Support | 2 | 4 | 2 | O | S/O | Steel Platform | 4/17/13 | 4/17/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/23/13 |
| SL03UB543 | Ubiquitel Jerome 99 | G051 | 4/29/13 | Lane | | | WT | Yes | 3/4/13 | 5/14/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Idaho | Outdoor | 225H | 225H | 225H | n/a | 4/17/13 | 4/17/13 | 5/15/13 | | Mary | | Tower | | | Nick | 3 | 177' | Self Support | 6 | 9 | 6 | O | O | Concrete Pad | 5/15/13 | 5/15/13 | | | | Need to remove existing dead lines to install new Hybrid cables | 200 A | N | N | Jacob Walker | n/a | | | | | Need to remove existing dead lines to install new Hybrid cables |
| SL03UB545 | Ubiquitel Magic Valley Mall | G052 | 6/5/13 | Lane | | | WT | Yes | 1/23/13 | 6/14/13 | Rejected | SA does not match CD, SA calls for the dragonwave CD does not | Yes | 2/14/13 | 6/1413 | Approved | n/a | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB547 | Ubiquitel Twin Falls | G053 | 3/27/13 | Lane | 1/25/13 | | TAIC | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 240H | 240H | 240H | n/a | 1/14/13 | 1/14/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 200' | Self Support | 6 | 9 | 6 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | Hy-Cap site need more room for all the cabinets | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL03UB548 | Ubiquitel Buhl | G054 | 5/6/13 | Lane | 2/15/13 | Yes | WT | Yes | 2/15/13 | 6/3/13 | Approved | n/a | Yes | 2/13/13 | 6/3/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 180 | 180 | 180 | n/a | 1/3/13 | 1/3/13 | 6/15/13 | | Mary | | Tower | | | Nick | 3 | 145' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 6/15/13 | 6/16/13 | | | | | 200 A | N | Y | Jacob Walker | n/a |
| SL03UB549 | Ubiquitel Kimberly | G055 | 5/10/13 | Lane | | | WT | Yes | 2/1/13 | 6/14/13 | Approved | n/a | Yes | 2/13/13 | 6/14/13 | Approved | n/a | No | n/a | Emily | Idaho | Single Outdoor | 270 | 270 | 270 | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | | Self Support | 3 | 6 | 3 | O | S/O | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB550 | Ubiquitel Hazelton Butte | G056 | 3/31/13 | Lane | 2/8/13 | | TAIC | Yes | 2/8/13 | 5/14/13 | Approved | n/a | Yes | 4/3/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 240 | n/a | 240 | n/a | 1/14/13 | 1/14/13 | 3/27/13 | | Mary | | Tower | | | Nick | 2 | 200' | Self Support | 2 | 4 | 2 | O | O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 5/2/13 |
| SL03UB552 | Ubiquitel Burley Butte | G057 | 4/19/13 | Lane | 3/29/13 | | TAIC | Yes | 1/29/13 | 6/5/13 | Approved | SA has been corrected | Yes | 4/1/13 | 6/5/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 180H | 195H | 195H | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | 120' | Self Support | 6 | 9 | 6 | O | O | Steel Platform | 5/2/13 | 5/2/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 5/1/13 |
| SL03UB553 | Ubiquitel - Burley Highway | G058 | 3/1/13 | Lane | 1/29/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 255 | 255 | 255 | n/a | 1/14/13 | 1/14/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 200' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/11/13 |
| SL03UB554 | Ubiquitel Rupert Junction | G059 | 3/29/13 | Lane | 1/15/13 | | TAIC | Yes | 3/12/13 | 6/5/13 | Approved | SA was corrected to show proper weight. | Yes | 2/12/13 | 6/5/13 | Approved | MA was corrected to show it matches. CD and SA. | No | n/a | Nick | Idaho | Indoor | 255 | 255 | 255 | n/a | 1/14/13 | 1/14/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 200' | Self Support | 3 | 6 | 3 | I | I | Shelter | 3/27/13 | 3/27/13 | | | | | 200 A | N | N | Jacob Walker | n/a | | | 4/22/13 |
| SL03UB556 | Ubiquitel Boarder Site | G060 | 5/4/13 | Lane | 2/15/13 | Yes | WT | Yes | 2/1/13 | 6/3/13 | Approved | See SA for Hybrid cable installment | Yes | 2/13/13 | 6/3/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 255 | 255 | n/a | n/a | 1/3/13 | 1/3/13 | 6/15/13 | | Mary | | Tower | | | Nick | 2 | 198' | Self Support | 2 | 4 | 2 | O | O | Steel Platform | 6/15/13 | 6/15/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. |
| SL03UB559 | Ubiquitel Lamar | G061 | 5/4/13 | Lane | | | WT | Yes | 2/1/13 | 6/14/13 | Approved | See SA for location to install Hybrid cables | No | n/a | 6/14/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB560 | American Falls | G062 | 4/25/13 | Lane | 2/4/13 | | WT | Yes | 1/31/13 | 6/14/13 | Approved | See SA for location to install Hybrid cables | No | n/a | 6/14/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | Single Outdoor | 255 | 255 | 255 | n/a | 1/3/13 | 1/3/13 | 4/24/13 | | Mary | | Tower | | | Nick | 3 | 195' | Self Support | 3 | 6 | 3 | OD | S/O | Steel Platform | 4/24/13 | 4/24/13 | | | | | 200 A | N | Y | Jacob Walker | n/a |
| SL03UB562 | Ubiquitel Frasure | G063 | 5/10/13 | Lane | | | WT | Yes | 2/12/13 | 6/14/13 | Approved | See SA for location to install Hybrid cables | No | n/a | 6/14/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB563 | Ubiquitel Logan | G010 | 6/7/13 | Lane | | | Powder River | Yes | 12/3/12 | 5/6/13 | Approved | n/a | Yes | 5/22/13 | 6/14/13 | Approved | MA has been corrected and approved | No | MA has been corrected. | Nick | Idaho | Single Outdoor | 150 | 150 | 150 | n/a | 1/14/13 | 1/14/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 110' | Monopole | 3 | 6 | 3 | O | S/O | Steel Plaform | 5/9/13 | 5/9/13 | | | | | 200 A | N | Y | Jacob Walker | n/a |
| SL03UB564 | Ubiquitel Layman | G064 | 5/5/13 | Lane | | | TAIC | No | n/a | 6/14/13 | n/a | No SA has been provided at this time. | Yes | 3/5/13 | 6/14/13 | Approved | n/a | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB568 | Blackfoot | G065 | 4/22/13 | Lane | 3/28/13 | | TAIC | No | Yes | 5/1/13 | Rejected | Did Structural and CD on wrong site - Self Support Tower is Failing | No | No | 5/14/13 | Rejected | Did mount analysis on wrong site this is a self support not a monpole | Yes | (Nick’s reply - Understand and agree fully on your comment, but there is an incorrect document uploaded.) | Nick | Idaho | Single Outdoor | 315 | 315 | 315 | n/a | 1/14/13 | 1/14/13 | | Send back, rejected -Wet Stamp - Site is completely wrong | Mary | | Tower | | | Nick | 3 | 180' | Self Support | 3 | 6 | 4 | ID | S/O | Shelter | 5/9/13 | 5/9/13 | | | | Sent back, rejected | 200 A | N | N | Jacob Walker | n/a |
| SL03UB572 | Ubiquitel Jamestown | G011 | 3/31/13 | Lane | 1/11/13 | | Powder River | Yes | 12/4/12 | 5/6/13 | Approved | Structural fails at Interim at 114%, but passes at Final at 104.3%, Crown will allow to build as long as the Interim will only be in place for 6 months. | Yes | 5/22/13 | 6/3/13 | Approved | MA has been corrected and approved | No | Everything has been cleared for Construction | Nick | Idaho | Outdoor | 255 | 255 | 255 | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | 189' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | N | Jacob Walker | Shane M. | | | 5/31/13 |
| SL03UB573 | Ubiquitel Telecom | G012 | 6/6/13 | Lane | | | Powder River | Yes | 11/30/12 | 5/6/13 | Approved | n/a | Yes | 5/22/13 | 6/3/13 | Approved | MA has been corrected and approved | No | Everything has been cleared for Construction | Nick | Idaho | Outdoor | 135 | 135 | 135 | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | 78' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 200 A | N | N | Jacob Walker | n/a |
| SL03UB574 | Ubiquitel Utah | G066 | 4/14/13 | Lane | 3/28/13 | | TAIC | No | n/a | 5/14/13 | n/a | n/a | Yes | 2/22/13 | 5/8/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 180 | 180 | 180 | n/a | 1/14/13 | 1/14/13 | 4/23/13 | | Mary | | Tower | | | Nick | 3 | 120' | Self Support | 3 | 6 | 3 | OD | O | Steel Platform | 4/23/13 | 4/23/13 | | | | | 200 A | N | N | Jacob Walker | Clay Schutzer |
| SL03UB575 | Ubiquitel Majestic | G013 | 5/11/13 | Lane | | | Powder River | Yes | 4/29/13 | 6/14/13 | Approved | n/a | Yes | 1/8/13 | 6/14/13 | Approved | n/a | No | n/a | Emily | Idaho | Outdoor | 210 | 210 | 210 | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | | Self Support | 3 | 6 | 3 | O | O | | | | | | | | | | | Jacob Walker | Shane M. |
| SL03UB576 | Ubiquitel Rigby | G067 | 3/30/13 | Lane | 1/8/13 | | TAIC | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 240 | 240 | 240 | n/a | 1/14/13 | 1/14/13 | | | Mary | | Tower | | | Nick | 3 | 176' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/24/13 |
| SL03UB578 | Ubiquitel Rexburg | G068 | 5/14/13 | Lane | | | WT | Yes | 2/1/13 | 6/16/13 | Rejected | SA does not match the CD, SA lists 6 c2A, CD calls for 3. | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB580 | Ubiquitel St. Anthony | G069 | 5/26/13 | Lane | | | WT | n/a | n/a | 6/16/13 | n/a | No SA provided at this time. | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB586 | Ubiquitel Snow King Mountain | G071 | 5/16/13 | Lane | | | TAIC | No | n/a | 6/16/13 | n/a | No SA has been provided at this time. | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB589 | Ubiquitel Jackson Airport | G072 | 5/19/13 | Lane | | | TAIC | No | n/a | 6/6/13 | n/a | No Structural has been ran | Yes | 6/3/13 | 6/6/13 | Approved | MA was corrected and Approved | No | there are two towers and to carriers at the samse RAD Center shooting right at each other. Safety issues and performance issues will be felt. | Nick | Idaho | Single Outdoor | 75 | 75 | 75 | n/a | 1/15/13 | 1/15/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 35' | Self Support | 3 | 6 | 4 | I | S/O | Shelter | 5/9/13 | 5/9/13 | | | | | | | | Jacob Walker | Shane M. |
| SL03UB590 | Ubiquitel Lower Valley | G073 | 4/3/13 | Lane | | | TAIC | No | n/a | 5/13/13 | n/a | No Structural ran at this time | Yes | 4/11/13 | 5/13/13 | Approved | 2 - Collars being added | No | n/a | Nick | Wyoming | Outdoor | 75 | 75 | n/a | n/a | 1/15/13 | 1/15/13 | | | Mary | | Tower | | | Nick | 2 | | Wooden Pole | 2 | 4 | 3 | | | | | | | | | | | | | Jacob Walker | Shane M. |
| SL03UB591 | Ubiquitel Table Rock | G074 | 4/11/13 | Lane | 2/25/13 | | TAIC | Yes | 1/17/13 | 5/13/13 | Approved | n/a | Yes | 4/5/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Outdoor | 165H | 165H | n/a | n/a | 1/14/13 | 1/14/13 | 4/17/13 | Given back to STA | Mary | | Tower | | | Nick | 2 | 99' | Monopole | 4 | 6 | 4 | OD | 2 - S/O | Steel Platform | 4/17/13 | 4/17/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden |
| SL03UB592 | Ubiquitel Cloverdale | G075 | 3/6/13 | Lane | 2/4/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | 6/3/13 | 6/3/13 | Approved | MA has been corrected and states that interim load was taken into calculations. | No | If they will provide a letter stating everything is good we can sign off. (Nick’s reply - Long as a Certified Letter is provided stating the Interim is good with everything on the mount, than this will be sufficient but we must have the Letter First, before Construction can begin.) - MA was corrected and everyting is approved. | Nick | Idaho | Single Outdoor | 150 | 150 | 150 | n/a | 1/14/13 | 1/14/13 | 3/22/13 | | Mary | | Tower | | | Nick | 3 | 110' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/22/13 | 3/22/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/12/13 |
| SL03UB593 | Boise Water Tank | G076 | n/a | Lane | | | TAIC | No | n/a | 6/16/13 | n/a | No SA has been provided at this time. | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | No owner approved CD uploaded to Siterra | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL03UB594 | Ubiguitel Vista | G077 | 6/24/13 | Lane | | | TAIC | No | n/a | 6/16/13 | n/a | No SA has been provided at this time. | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | Clay Schutzer |
| SL03UB595 | Ubiquitel North Eagle | G078 | 4/24/13 | Lane | 2/21/13 | | TAIC | Yes | 2/22/13 | 5/10/13 | Approved | New mount to be installed on Wooden Pole | Yes | 2/22/13 | 5/10/13 | Approved | new mount on wooden Pole | No | n/a | Nick | Idaho | Single Outdoor | 150H | 150H | 150H | n/a | 1/4/13 | 1/4/13 | | | Mary | | Tower | | | Nick | 2 | 70' | Wooden Pole | 4 | 6 | 8 | O | S/O | Steel Platform | 6/15/13 | 6/15/13 | | | | Supplemental BOM Created | 200 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03UB596 | Ubiquitel Watson | G014 | 6/23/13 | Lane | 3/29/13 | | Powder River | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Rejected | Mount analysis was not ran for the 6 RRUs, only calculated 3 of the 6. Need a Letter verifing everything is clear or redo the Structural. | Yes | Verifing everything is good | Nick | Idaho | Single Outdoor | 135 | 135 | 135 | n/a | 1/14/13 | 1/14/13 | 5/2/13 | | Daren | | Tower | | | Nick | 3 | 88' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/2/13 | 5/2/13 | | | | | 200 A | N | Y | Jacob Walker | n/a |
| SL03UB597 | Ubiquitel Kuna | G079 | 5/2/13 | Lane | 3/28/13 | | TAIC | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 225 | 225 | 225 | n/a | 1/14/13 | 1/14/13 | 5/2/13 | | Daren | | Tower | | | Nick | 3 | 181' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 5/2/13 | 5/2/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/11/13 |
| SL03UB600 | Ubiquitel Kuna | G081 | 5/19/13 | Lane | | | TAIC | No | n/a | 5/24/13 | n/a | MA was uploaded as a SA | Yes | 4/26/13 | 5/24/13 | Rejected | MA - MA doesn’t identify the three new mounts and the two different towers that the three are going to be installed on. It was ran for the mount that will be placed on Tower 1 at 18’ Nothing is showing for Tower 2. Also there is not mention of the weight of the existing antennas on the new mount. Please have these corrected and sent back to the AE Team. CD - CD is showing swapping out the only BBU on the site. There is not Batteries in the existing CDMA cabinet. There is a generator on site but it is labeled not installed on the AC panel. Please review this, b/c for what I see we are going to need to expand the pad 3’ x 3’ to install the MMBS. | No | n/a | Nick | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB609 | Ubiquitel Hampton | G084 | 6/7/13 | Lane | | | WT | Yes | 2/1/13 | 6/16/13 | Approved | See SA for location to install Hybrid cables | No | n/a | 6/16/13 | n/a | No MA provided at this time | No | n/a | Emily | Idaho | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB610 | Ubiquitel West Twin Falls | G085 | 6/5/13 | Lane | 2/15/13 | Yes | WT | Yes | 2/26/13 | 6/3/13 | Approved | See SA for Hybrid cable installment | Yes | 2/13/13 | 6/3/13 | Approved | CD needs to have the RAD Center corrected from 175' to 170' | No | n/a | Nick | Idaho | Outdoor | 240 | 240 | 240 | n/a | 1/15/13 | 1/15/13 | | | Mary | | Tower | | | Nick | 3 | 175' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 6/15/13 | 6/15/13 | | | | | 200 A | N | N | Jacob Walker | Shane M. |
| SL03UB611 | Ubiquitel South Nampa | G086 | 4/24/13 | Lane | 2/11/13 | | TAIC | Yes | 2/13/13 | 6/16/13 | Approved | n/a | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | No owner approved CD uploaded to Siterra | Emily | Idaho | Single Outdoor | 150H | 150H | 150H | n/a | 1/4/13 | 1/4/13 | 4/17/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 6 | 9 | 6 | O | S/O | Concrete Pad | 5/3/13 | 5/3/13 | | | | Install 3 hand rails | 200 A | N | N | Jacob Walker | n/a |
| SL03UB613 | Ubiquitel Broadway | G087 | 6/8/13 | Lane | | | TAIC | Yes | 5/6/13 | 6/7/13 | Rejected | SA & MA was not ran for hanging 1 standoff mount off each mount. This site was ran as a antenna swap out. MA & SA both need to be corrected to show what is designed | Yes | 5/6/13 | 6/7/13 | Rejected | SA & MA was not ran for hanging 1 standoff mount off each mount. This site was ran as a antenna swap out. MA & SA both need to be corrected to show what is designed | Yes | a letter needs to be provided stating everything is voorected. | Nick | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB614 | Ubiquitel Stone | G088 | 5/30/13 | Lane | | | TAIC | Yes | 4/11/13 | 5/10/13 | Approved | Wooden Pole, 2 mounts to be installed, with 3 collars | Yes | 4/11/13 | 5/10/13 | Approved | Wooden Pole, 2 mounts to be installed, with 3 collars | No | n/a | Nick | Idaho | Outdoor | 105 | 105 | 105 | n/a | 1/15/13 | 1/15/13 | | | Mary | | Tower | | | Nick | 3 | 65' | Wooden Pole | 3 | 6 | 3 | O | O | Steel Platform | 5/10/13 | 5/10/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. | | | 5/29/13 |
| SL03UB615 | Ubiquitel North Meridian | G089 | 4/28/13 | Lane | | | TAIC | Yes | 3/9/13 | 6/16/13 | Approved | n/a | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB617 | Ubiquitel Eccles Theatre | H180 | 8/13/13 | Lane | | | TAIC | No | n/a | 6/16/13 | n/a | No SA has been provided at this time. | Yes | 2/11/13 | 6/16/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Emily | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB620 | Ubiquitel East Nampa | G090 | 4/5/13 | Lane | 3/4/13 | | TAIC | No | n/a | 4/30/13 | n/a | Nothing received | No | n/a | 4/30/13 | n/a | No MA provided at this time | n/a | CD needs corrections | Nick | Idaho | Single Outdoor | 165H | 165H | 165H | n/a | 1/3/13 | 1/3/13 | | | Mary | | Tower | | | Nick | 3 | | Water Tank | 6 | 9 | 6 | | | | | | | | | | | | | Jacob Walker | n/a | | | 4/19/13 |
| SL03UB622 | Ubiquitel South Meridian | G091 | 6/9/13 | Lane | | | WT | Yes | 2/11/13 | 617/13 | Approved | See SA for location to install Hybrid cables | No | n/a | 6/17/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB623 | Ubiquitel E. St. George | H181 | 3/31/13 | Lane | 1/9/13 | | Fullerton | Yes | 3/13/13 | 6/16/13 | Approved | See SA for location to install Hybrid cables | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Utah | Indoor | 105 | 105 | 105 | n/a | 1/2/13 | 1/2/13 | | | Mary | | Tower | | | Nick | 3 | 50' | Monopole | 3 | 6 | 4 | I | I | Shelter | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL03UB624 | Ubiquitel West Nampa | G092 | 4/17/13 | Lane | 2/11/13 | | TAIC | Yes | 3/12/13 | 5/10/13 | Approved | n/a | Yes | 4/30/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Idaho | Outdoor | 150H | 150H | 150H | n/a | 1/15/13 | 1/15/13 | 5/3/13 | | Mary | | Tower | | | Nick | 3 | 90' | Monopole | 6 | 9 | 6 | O | O | Steel Platform | 5/3/13 | 5/3/13 | | | | Install 3 hand rails | 200 A | N | N | Jacob Walker | Clay Schutzer |
| SL03UB627 | Ubiquitel East Eagle | G093 | 5/22/13 | Lane | 3/3/13 | Yes | WT | Yes | 1/30/13 | 6/3/13 | Approved | n/a | Yes | 2/14/13 | 6/3/13 | Approved | n/a | No | Bird Nest in the Tower | Nick | Idaho | Single Outdoor | 165 | 165 | 165 | n/a | 1/15/13 | 1/15/13 | 6/15/13 | | Mary | | Tower | | | Nick | 3 | 118' | Monopole | 3 | 6 | 6 | O | S/O | Steel Platform | 6/15/13 | 6/16/13 | | | | Birds Nest | 200 A | N | N | Jacob Walker | n/a | | | | | Birds Nest |
| SL03UB633 | Ubiquitel - North Rexburg | G015 | 5/17/13 | Lane | | | Powder River | Yes | 12/4/13 | 5/13/13 | Approved | n/a | Yes | 1/24/13 | 5/13/13 | Approved | n/a | No | No Hot Slide needed | Nick | Idaho | Outdoor | 150 | 150 | 150 | n/a | 1/15/13 | 1/15/13 | 5/15/13 | | Mary | | Tower | | | Nick | 3 | 116' | Self Support | 3 | 6 | 3 | O | O | Steel Platform | 5/15/13 | 5/15/13 | | | | | 200 A | N | N | Jacob Walker | n/a |
| SL03UB634 | Ubiquitel East Twin Falls | G095 | 5/9/13 | Lane | | | WT | Yes | 1/31/13 | 6/17/13 | Approved | See SA for location to install Hybrid cables | Yes | 2/14/13 | 6/17/13 | Rejected | MA does not match CD and SA, RAD center is 99' MA states 199' | Yes | Letter needed to show that the statement of one hundred and ninety nine feet, on MA was a typed in error and that RAD center is ninety nine feet | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB636 | Ubiquitel Maple Grove | G096 | 5/29/13 | Lane | | | WT | No | n/a | 6/16/13 | n/a | No SA has been provided at this time. | No | n/a | 6/16/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB637 | Cassia | G097 | 5/10/13 | Lane | | | WT | Yes | 2/6/13 | 5/10/13 | Approved | n/a | Yes | 6/3/13 | 6/7/13 | Approved | MA has been corrected and approved | No | n/a | Nick | Idaho | Single Outdoor | 180 | 180 | 180 | n/a | 1/15/13 | 1/15/13 | | | Mary | | Tower | | | Nick | 3 | 113' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/10/13 | 5/10/13 | | | | | 200 A | N | N | Jacob Walker | Clay Schutzer |
| SL03UB639 | Ubiquitel Western Aircraft | G098 | 6/21/13 | Lane | | 5/29/13 | TAIC | Yes | 4/18/13 | 6/12/13 | Approved | n/a | Yes | Yes | 6/12/13 | Approved | n/a | No | Three Cantaliver mounts needed. | Dez | Idaho | Single Outdoor | 270 | 270 | 270 | n/a | 1/15/13 | 1/15/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | O | S/O | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB642 | View Point Buildiing | G100 | 5/20/13 | Lane | | | TAIC | No | n/a | 5/13/13 | n/a | No Structural as of this time | Yes | 3/5/13 | 5/13/13 | Rejected | Mount analysis was ran for adding 2 new cantilever mount to the building. Not a Stand off mount as the CD shows. | Yes | Need a letter approving this land owner. | Nick | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB659 | Ubiquitel - Williamson | G101 | 3/21/13 | Lane | 2/8/13 | | TAIC | Yes | 6/11/13 | 6/11/13 | Approved | SA was ran at the correct height. The CD and mA are being corrected. | Yes | n/a | 5/14/13 | Rejected | Mount analysis needs to be reran with correct information, It states in the letter that everything appears to be correct, from the Structural and CD, but we have conflicting information. | Yes | Letter stating where the mount calculations were run and with what information. - New Structural and Mount analysis to be reran. | Nick | Idaho | Outdoor | 165 | 165 | n/a | n/a | 1/15/13 | 1/15/13 | 3/26/13 | | Mary | | Tower | | | Nick | 2 | 120' | Self Support | 2 | 4 | 2 | O | S/O | Concrete Pad | 3/26/13 | 3/26/13 | | | | | 200 A | N | Y | Jacob Walker | n/a | | | 4/30/13 |
| SL03UB660 | Teton Mall | G016 | 6/13/13 | Lane | | 1/31/13 | Powder River | Yes | 4/22/13 | 6/12/13 | Approved | See SA for beef up. No tower work allowed till structure is beefed up. No hot slide needed. | Yes | Yes | 6/12/13 | Approved | n/a | No | n/a | Dez | Idaho | Single Outdoor | 255 | 255 | 255 | n/a | 1/15/13 | 1/15/13 | | | Mary | | Tower | | | Nick | 3 | 173' | Self Support | 3 | 6 | 3 | O | S/O | Steel Platform | 6/15/13 | 6/15/13 | | | | | 200 A | N | N | Jacob Walker | Shane M. |
| SL03UB665 | Ubiquitel Shelley | G017 | 5/4/13 | Lane | | | Powder River | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Rejected | Mount analysis was not ran for the 6 RRUs, only calculated 3 of the 6. Need a Letter verifing everything is clear or redo the Structural. | Yes | verifing the calculations and everything is good. | Nick | Idaho | Single Outdoor | 240 | 240 | 240 | n/a | 1/15/13 | 1/15/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 187' | Self Support | 3 | 6 | 3 | O | S/O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 200 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03UB668 | Ubiquitel Signal Mountain | G102 | 8/30/13 | Lane | | n/a | TAIC | No | n/a | 6/12/13 | n/a | No SA provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03UB670 | Ubiquitel Apre Vous | G104 | 3/31/13 | Lane | 2/19/13 | | TAIC | No | n/a | 5/13/13 | n/a | No Structural received at this time | No | n/a | 5/13/13 | n/a | No MA provided at this time | No | n/a | Nick | Wyoming | Indoor | 150 | 150 | 150 | n/a | 1/3/13 | 1/3/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopine | 3 | 6 | 5 | I | I | Shelter | 3/27/13 | 3/27/13 | | | | Need to run 2 Conduits for new coax. | 200 A | N | N | Jacob Walker | Shane M. | | | 5/15/13 |
| SL03UB675 | Ubiquitel Weiser | G105 | 4/15/13 | Lane | 1/28/13 | | TAIC | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | Yes | verifing everything is correct. | Nick | Idaho | Single Outdoor | 180 | 180 | 180 | n/a | 1/3/13 | 1/3/13 | 4/17/13 | Given back to STA | Mary | | | | | Nick | 3 | 94' | Rooftop | 3 | 6 | 3 | ID | S/O | Concrete Floor | 4/17/13 | 4/17/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL03UB686 | Ubiquitel Alameda | G108 | 6/3/13 | Lane | | n/a | TAIC | No | n/a | 6/12/13 | n/a | No SA provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Idaho | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | Shane M. |
| SL03XC010 | Ernies Auto | H018 | 6/5/13 | Lane | | | Caltrop | Yes | 12/4/12 | 5/20/13 | Approved | n/a | Yes | 2/4/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 1/11/13 | 1/11/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 58' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | N | Daren Holt | n/a |
| SL03XC102 | North Ogden City | H019 | 2/15/13 | Lane | 2/15/13 | | Caltrop | Yes | n/a | 5/8/13 | Approved | n/a | Yes | n/a | 5/8/13 | Approved | Hot slide not needed | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | Cabinet will have to be turned, very small platform | Mary | | Tower | | | Nick | 3 | 98' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Steve Mann |
| SL03XC104 | Plain City | H020 | 2/27/13 | Lane | 2/18/13 | | Caltrop | Yes | 12/7/13 | 5/13/13 | Approved | n/a | Yes | 1/28/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | No possible dual install, small platform | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC106 | Doc Holiday & Frank Kuba | H021 | 6/14/13 | Lane | | | Caltrop | Yes | 12/5/12 | 5/20/13 | Approved | n/a | Yes | 2/4/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/11/13 | 1/11/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC108 | Mt. Eyre City Park | H022 | 4/15/13 | Lane | 2/28/13 | | Caltrop | Yes | 12/6/12 | 5/13/13 | Approved | n/a | Yes | 2/4/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/111/13 | 1/11/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 98' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Jacob Walker | n/a | | | 5/14/13 |
| SL03XC110 | Norma Elliot | H023 | 4/23/13 | Lane | 3/4/13 | | Caltrop | Yes | 12/4/12 | 5/20/13 | Approved | n/a | Yes | 2/4/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/11/13 | 1/11/13 | 4/18/13 | | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC112 | 4th St. Ball Park | H024 | 4/14/13 | Lane | 3/12/13 | | Caltrop | Yes | 12/5/12 | 5/20/13 | Approved | n/a | Yes | 2/4/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/11/13 | 1/11/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC114 | TCI | H025 | 4/22/13 | Lane | 3/15/13 | | Caltrop | Yes | 12/6/13 | 5/13/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/11/13 | 1/11/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 3 | 6 | 6 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC118 | Clair Baur | H027 | 2/21/13 | Lane | 2/27/13 | | Caltrop | Yes | 12/5/13 | 5/14/13 | Approved | n/a | Yes | 1/28/13 | 5/14/13 | Approved | n/a | No | No Hot Slide is needed | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | No possible dual install, small covered platform | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC120 | Ogden City Municipal Building | H182 | 6/13/13 | Lane | | n/a | TAIC | Yes | 4/4/13 | 6/12/13 | Rejected | No cantilever brackets called for in SA. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC122 | Mt. Ogden Water Tank | H183 | n/a | Lane | | n/a | ERROR:#N/A | No | n/a | 6/12/13 | n/a | No SA provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL03XC124 | Carl Favero | H028 | 6/17/13 | Lane | | | Caltrop | Yes | 12/6/12 | 5/13/13 | Approved | n/a | Yes | 2/6/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 1/11/13 | 1/11/13 | | | Mary | | Tower | | | Nick | 3 | 98' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/15/13 | 5/15/13 | | | | Need to remove BBU to set MMBS | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC126 | Kenneth Baldwin | H029 | 2/20/13 | Lane | 2/19/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | Will have to be a temporary install, no room until decomm. | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | Y | Y | Jacob Walker | Clay Schutzer |
| SL03XC128 | Ogden Municipal Airport | H030 | 7/4/13 | Lane | | n/a | Caltrop | Yes | 11/30/12 | 6/12/13 | Approved | n/a | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC130 | Washington Heights Corp | H031 | 2/20/13 | Lane | 2/19/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | No possible dual install, small covered platform | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC132 | South Ogden Water Tank | H184 | 3/31/13 | Lane | 3/5/13 | | TAIC | No | n/a | 5/31/13 | n/a | No Structural Analysis at this time | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 180 | 165 | 255 | n/a | 1/11/13 | 1/11/13 | | | Mary | | Tower | | | Nick | 3 | 42' | Water Tank/Wooden Pole | 3 | 6 | 5 | O | S/O | Steel Platform | | | | | | Sent to Mary for Verification | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC134 | Dallas Green | H032 | 2/20/13 | Lane | 2/25/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/11/13 | 1/11/13 | 3/25/13 | Will have to be a temporary install, no room until decomm. | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC136 | Kwik City Muffler | H033 | 7/11/13 | Lane | | n/a | Caltrop | No | n/a | 6/12/13 | n/a | No SA provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC138 | Roy Water Conservacy | H034 | 3/19/13 | Lane | 3/4/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 1/15/13 | 1/15/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 58' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/26/13 | 3/26/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. | | | | | Birds Nest - sent to Lane |
| SL03XC140 | Ron Nitler | H035 | 2/15/13 | Lane | 2/19/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/15/13 | 1/15/13 | 3/25/13 | Will have to be a temporary install, no room until decomm. | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC142 | Ray's Valley Service | H036 | 2/20/13 | Lane | 2/19/13 | | Caltrop | Yes | 12/1/13 | 5/13/13 | Approved | n/a | Yes | 1/28/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/15/13 | 1/15/13 | 3/25/13 | No possible dual install, small platform | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | N | Jacob Walker | Shane M. |
| SL03XC144 | Prime Communications | H185 | 6/3/13 | Lane | | 4/29/13 | TAIC | Yes | 2/28/13 | 6/12/13 | Approved | n/a | Yes | n/a | 6/12/13 | Approved | n/a | No | n/a | Dez | Utah | Single Outdoor | 210 | 210 | 210 | n/a | 1/15/13 | 1/15/13 | | | Mary | | Tower | | | Nick | 3 | 75' | Self Support | 3 | 6 | 3 | O | S/O | Steel Platform | 6/15/13 | 6/15/13 | | | | | 100 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/24/13 |
| SL03XC146 | Weber Basin Water | H037 | 7/11/13 | Lane | | | Caltrop | Yes | 12/4/12 | 5/29/13 | Approved | n/a | Yes | 1/31/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/15/13 | 1/15/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC148 | Lovell | H038 | 6/11/13 | Lane | | | Caltrop | Yes | 12/12/12 | 5/29/13 | Approved | n/a | Yes | 1/31/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/15/13 | 1/15/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC150 | Sunset City | H039 | 5/6/13 | Lane | | | Caltrop | Yes | 12/7/13 | 5/13/13 | Approved | Fails at Interim at 107.7%, Passes at Final 104.5%, new and existing equpt can't be on tower longer than 6 months | Yes | 1/28/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/25/13 | 1/25/13 | | | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/15/13 | 5/15/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC152 | Peters | H040 | 3/30/13 | Lane | 3/4/13 | | Caltrop | Yes | 12/6/12 | 5/20/13 | Approved | n/a | Yes | 1/28/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/25/13 | 1/25/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 100 A | N | Y | Daren Holt | Clay Schutzer |
| SL03XC154 | Fire Station #2 | H041 | 3/20/13 | Lane | 2/28/13 | | Caltrop | Yes | 1/19/13 | 5/14/13 | Approved | n/a | Yes | 1/31/13 | 5/14/13 | Approved | n/a | No | | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/25/13 | 1/25/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/26/13 | 3/26/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC156 | Bates Canyon | H042 | 5/7/13 | Lane | | | Caltrop | Yes | 12/10/12 | 5/20/13 | Approved | n/a | Yes | 1/31/13 | 6/17/13 | Approved | MA wsa corrected to show 44' | No | MA has been corrected. | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 1/25/13 | 1/25/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 44' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC158 | Nancy Gardner | H043 | 2/15/13 | Lane | 2/27/13 | | Caltrop | Yes | n/a | 5/8/13 | Approved | n/a | Yes | n/a | 5/8/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/25/13 | 1/25/13 | 3/25/13 | Will have to be a temporary install, no room until decomm. | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Steve Mann |
| SL03XC160 | St. Ambrose Church | H186 | 3/6/13 | Lane | 1/23/13 | | Smith Hyatt | Yes | 6/11/13 | 6/11/13 | Approved | SA was corrected. Need a Mason to fix the brick and walls before antennas and RRUS can be installed. | Yes | 6/11/13 | 6/11/13 | Approved | MA has been corrected. Consolidation on the Alpha Sector and Mason needs to be hired and fix the Bricks before wwe proceed with hanging the antennas and RRUs. | Yes | Need a mason to fix brick work. MA & SA are corrected and approved. | Nick | Utah | Single Outdoor | 240 | 240 | 240 | n/a | 1/28/13 | 1/28/13 | 3/25/13 | Will have to be a temporary install, no room until decomm. | Mary | | Non-Tower | | | Nick | 3 | 55' | Rooftop | 3 | 6 | 3 | O | S/O | Steel Platform | | | | | | Need a CS to walk and provide pictures in Steeple | 100 A | N | Y | Jacob Walker | n/a | | | | | Must contact Church to scheule construction dates and times. ContactMirko at 801-560-3042 |
| SL03XC162 | JP's Texaco | H044 | 2/15/13 | Lane | 3/12/13 | | Caltrop | Yes | 12/6/12 | 5/14/13 | Approved | n/a | Yes | 1/28/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/25/13 | 1/25/13 | 3/25/13 | No possible dual install, small platform | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC164 | Public Works | H045 | 8/1/13 | Lane | | | Caltrop | Yes | 12/10/12 | 5/20/13 | Approved | n/a | No | n/a | 6/7/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/28/13 | 1/28/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC166 | Andy Adams Park | H046 | 3/20/13 | Lane | | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/28/13 | 1/28/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 98' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/26/13 | 3/26/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC168 | Stoken's Nursery | H047 | 4/10/13 | Lane | 3/15/13 | | Caltrop | Yes | 12/17/12 | 5/20/13 | Approved | n/a | Yes | 2/6/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | 135 | 1/28/13 | 1/28/13 | 4/18/13 | Need more Lease space to set all 4 cabinets | Mary | | Tower | | | Nick | | 95' | Monopole | 4 | 8 | 7 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | Need to expand the Pad - 2 MMBS and 2 BBUs | 100 A | Y | Y | Jacob Walker | Shane M. |
| SL03XC172 | Kaysville | H187 | 5/1/13 | Lane | | n/a | TAIC | No | n/a | 6/12/13 | n/a | No SA provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC174 | Cherry Hill | H048 | 3/9/13 | Lane | 12/21/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 1/28/13 | 1/28/13 | 3/25/13 | No possible dual install, small platform | Mary | | Tower | | | Nick | 3 | 58' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC176 | Burmester | H049 | 4/27/13 | Lane | 3/5/13 | | Caltrop | Yes | 12/6/12 | 5/29/13 | Approved | n/a | Yes | 2/11/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 225 | 225 | 225 | n/a | 1/29/13 | 1/29/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 187' | Self Support | 3 | 6 | 4 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | | | | Daren Holt | Steve Mann |
| SL03XC178 | Davis County Sheriff | H188 | 3/23/13 | Lane | 1/31/13 | | TAIC | No | n/a | 6/12/13 | n/a | No Structural ran at this time | Yes | 6/3/13 | 6/12/13 | Approved | MA has been corrected and approved | Yes | MA was corrected and approved, we are using 3' standoffs. SA still hasn't been completed. | Nick | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 1/29/13 | 1/29/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 100' | Self Support | 3 | 6 | 4 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 100 A | N | Y | Jacob Walker | n/a | | | 4/11/13 |
| SL03XC180 | Fruit Heights | H189 | 4/10/13 | Lane | 2/11/13 | | TAIC | No | n/a | 5/8/13 | n/a | No Structural | Yes | n/a | 5/8/13 | Approved | New 4 sector mount | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | 120 | 1/29/13 | 1/29/13 | | Sent to Mary for Corrections | Mary | | Tower | | | Nick | 4 | 68' | Monopole | 4 | 8 | 6 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | Sent to Mary for corrections, - 4 Sector Site not enough room for the additional Cabinets. | 100 A | Y | Y | Jacob Walker | n/a | | | | | Need to paint to match and replace existing 7/8 snap-ins to make room. |
| SL03XC182 | Bangeter Wood Warehouse | H050 | 2/15/13 | Lane | 2/20/13 | | Caltrop | Yes | n/a | 5/8/13 | Approved | n/a | Yes | n/a | 5/8/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 1/29/13 | 1/29/13 | 3/25/13 | No possible dual install, small platform | Mary | | Tower | | | Nick | 3 | 117' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100A | N | Y | Jacob Walker | Shane M. |
| SL03XC184 | Bountiful Police Dept. | H051 | 3/28/13 | Lane | 2/28/13 | | Caltrop | Yes | 12/7/13 | 5/13/13 | Approved | n/a | Yes | 1/28/13 | 5/13/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 99' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC186 | Western Wireless Collocate | H190 | 5/22/13 | Lane | | n/a | TAIC | No | n/a | 6/12/13 | n/a | No SA provided at this time. | No | n/a | 6/12/13 | n/a | No MA provided at this time | n/a | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC188 | Beehive Storage | H052 | 2/15/13 | Lane | 12/19/12 | | Caltrop | Yes | 12/7/12 | 5/15/13 | Approved | n/a | Yes | 2/11/13 | 5/15/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 3/25/13 | No possible dual install, small covered platform | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC192 | Kulmer & Schumacher | H054 | 3/30/13 | Lane | 2/27/13 | | Caltrop | Yes | 12/17/12 | 5/10/13 | Approved | n/a | Yes | 2/11/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer | | | 6/5/13 |
| SL03XC194 | Justice | H055 | 4/6/13 | Lane | 3/6/13 | | Caltrop | Yes | 1/16/13 | 5/14/13 | Approved | CD shows stand off on the existing pipe, structural was ran for 10' mount, GD BOM was ordered with a small dual stand-off arm (30"x19") Need a Letter verifing we can use the smaller mount | No | n/a | 5/14/13 | n/a | No MA provided at this time | Yes | Need a letter approving the smaller mount. | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | | CD needs to be changed to show changing out the existing mount. | Mary | | Tower | | | Nick | 3 | 59' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 100 A | N | N | Jacob Walker | n/a |
| SL03XC202 | Sons of Pioneers | H191 | 4/30/13 | Lane | | | Smith Hyatt | Yes | 5/31/13 | 5/31/13 | Approved | n/a | Yes | 5/31/13 | 5/31/13 | Approved | CD/ MA and SA match. Everything is approved | Yes | Everything is approved and good to go. | Nick | Utah | Single Indoor | 150 | 150 | 180 | n/a | 1/29/13 | 1/29/13 | 5/28/13 | Need Site Walk | Mary | | Tower | | | Nick | 3 | 20'/26'/26' | Rooftop | 3 | 6 | 5 | I | S/I | Storage Closet | 5/28/13 | 5/28/13 | | | | | 200 A | N | N | Daren Holt | Steve Mann | | | 4/26/13 |
| SL03XC204 | Robert Wolff | H056 | 5/23/13 | Lane | | 4/1/13 | Caltrop | Yes | 12/11/12 | 5/29/13 | Approved | n/a | Yes | 1/28/13 | 6/18/13 | Rejected | OA drawings call for 2 powerwaves and one KMW. MA calls for two powerwaves and two KMW attennas. MA needs to be adjusted. | No | n/a | Nick, Dez (MA) | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 5/31/13 | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/31/13 | 5/31/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC206 | Sunset Tower | H192 | 5/14/13 | Lane | 3/2/13 | | Smith Hyatt | Yes | 5/31/13 | 5/31/13 | Approved | 2 - step only for Equipment - Do not sit both BBU Cabinets together | Yes | 5/31/13 | 6/3/13 | Approved | MA has been corrected to install 3 Cantilever Mounts to the side of the building. MA matches the CD. | Yes | SA & MA have been corrected and they match the CD. | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 170' | Rooftop | 3 | 6 | 3 | O | S/O | Roof Platform | 5/9/13 | 5/9/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC208 | University Park | H193 | 4/27/13 | Lane | | | Smith Hyatt | Yes | 5/23/13 | 5/23/13 | Approved | Structure is approved to with hold the new Eqipment | Yes | 5/23/13 | 5/23/13 | Approved | Install 2 antennas on the 2 skids and install new antenna on new cantilever mount and remove the old antennas and mounts at Final | Yes | Letter verifing the Blastard is good. - Letter confirmed everything is good - 5/23/13 | Nick | Utah | Single Outdoor | 135 | 225 | 210 | n/a | 1/29/13 | 1/29/13 | | | Mary | | Tower | | | Nick | 3 | 90' | Rooftop | 3 | 6 | 4 | O | S/O | Roof Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Jacob Walker | n/a | | | 5/24/13 | | consolidate the alpha CDMA antennas on one of the existing mass pipes and add 2 new mass pipes for the sleds for Beta and Gamma. |
| SL03XC210 | Salt Lake City Airport | H194 | 5/23/13 | Lane | | n/a | TAIC | Yes | 4/3/13 | 6/13/13 | Rejected | RRU's need to be mounted on cantiliver mounts behind the walls on alpha and beta. Antennas need to be painted to match. (GD note: Two 4" holes per sector need to be drilled for jumpers to come through the walls with boots.)- If we are to use the sled mounts, they are nit identified in the SA for using on both sectors, and a specific sled mount was called out. Sled Mount is not in the Calculations page., | Yes | 4/3/13 | 6/13/13 | Rejected | RRU's need to be mounted on cantiliver mounts behind the walls on alpha and beta. Antennas need to be painted to match. (GD note: Two 4" holes per sector need to be drilled for jumpers to come through the walls with boots.) | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC212 | Robert Wallace | H057 | 4/19/13 | Lane | 1/9/13 | | Caltrop | Yes | 12/17/12 | 5/10/13 | Approved | n/a | Yes | 6/7/13 | 6/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135H | 135H | 135H | n/a | 1/29/13 | 1/29/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 6 | 9 | 6 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | | 100A | Y | Y | Jacob Walker | Clay Schutzer |
| SL03XC214 | North Temple Storage | H058 | 4/15/13 | Lane | 1/16/13 | | Caltrop | Yes | 1/19/13 | 5/13/13 | Need Letter | Need Letter, CD shows stand-off on the existing and new chain mount, Structural shows 10' mount | Yes | 2/11/13 | 5/13/13 | Need Letter | Need Letter, Mount analysis was done on a new 12' 6" mount and not Standoff or 6 position chain mount for RRUs. | Yes | BOM was ordered with a single collar and dual standoff small 30" x 19" mount. | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 68' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Jacob Walker | Clay Schutzer |
| SL03XC216 | Tribune | H195 | 4/13/13 | Lane | | | Smith Hyatt | Yes | 5/31/13 | 6/3/13 | Approved | Structural was corrected | Yes | 5/31/13 | 6/3/13 | Approved | n/a | Yes | Letter stating the Structure will be okay to with stand the RRUs and Cantilever mount on the inside of the wall. | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | | | Mary | | Tower | | | Nick | 3 | 148' | Rooftop | 3 | 6 | 4 | | | | | | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC218 | St. Mark's | H196 | 4/13/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/8/13 | n/a | No SA provided at this time. | Yes | 5/31/13 | 6/21/13 | Approved | n/a | Yes | Verifing that the current mount can with stand another 60 lbs. | Nick | Utah | Single Outdoor | 150 | 225 | 150 | n/a | 1/29/13 | 1/29/13 | | | Mary | | | | | Nick | 3 | 95' | Rooftop | 3 | 6 | 3 | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC220 | Charleston Apartments | H197 | 5/16/13 | Lane | | CD redlined on 6/13/13 | Smith Hyatt | Yes | 4/13/13 | 6/13/13 | Approved | n/a | Yes | 2/25/13 | 6/13/13 | Approved | n/a | No | n/a | Dez | Utah | Single Outdoor | 90H | 180H | 150H | 210H | 1/29/13 | 1/29/13 | | | Mary | | | | | Nick | 4 | | Rooftop | 8 | 12 | 10 | O | 2 - S/O | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC224 | Freedom Mortgage | H199 | 4/27/13 | Lane | | | Smith Hyatt | Yes | 2/27/13 | 5/29/13 | Approved | n/a | Yes | 2/27/13 | 5/29/13 | Approved | n/a | No | Need Site visit to order GD Materials | Nick | Utah | Single Outdoor | 210 | 240 | 240 | n/a | 2/1/13 | 2/1/13 | | | Mary | | Tower | | | Nick | 3 | 45' | Rooftop | 3 | 6 | 3 | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC228 | Evans | H059 | 5/29/13 | Lane | | | Caltrop | Yes | 12/11/12 | 5/29/13 | Approved | n/a | Yes | 2/11/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 1/29/13 | 1/29/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 61' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Jacob Walker | n/a |
| SL03XC230 | Smith's Credit Union | H200 | 6/3/13 | Lane | | n/a | TAIC | No | n/a | 6/13/13 | n/a | No SA provided at this time. | No | n/a | 6/13/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC232 | SL County Housing Authority | H201 | 4/27/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/7/13 | Approved | ran for installing 3 new cantilever mounts, not a standoff | Yes | n/a | 5/7/13 | Rejected | RRUs were not calcuated ing the weigh and nothing is shown for mounting the antennas | Yes | Letter verifing everything is good | Nick | Utah | Outdoor | 195 | 90 | 90 | n/a | 1/29/13 | 1/29/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 230' | Rooftop | 3 | 6 | 3 | O | O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 100 A | N | Y | Jacob Walker | Shane M. |
| SL03XC234 | Parkview Plaza (Mecham) | H202 | 7/1/13 | Lane | | 4/12/13 | Smith Hyatt | Yes | 4/17/13 | 6/13/13 | Approved | n/a | Yes | 4/17/13 | 6/13/13 | Approved | n/a | No | n/a | Dez | Utah | Single Outdoor | 195 | 285 | 165 | 165 | 1/25/13 | 1/25/13 | | | Mary | | | | | Nick | 4 | | Rooftop | 4 | 8 | 5 | O | S/O | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC236 | Dan's Grocery | H060 | 4/20/13 | Lane | 3/5/13 | | Caltrop | Yes | 12/12/12 | 5/10/13 | Approved | n/a | Yes | 2/11/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 1/29/13 | 1/29/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 59' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100A | N | Y | Daren Holt | Chris E. |
| SL03XC238 | Eagel Point | H203 | 6/3/13 | Lane | | 2/26/13 | Smith Hyatt | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC240 | International Center | H204 | 5/25/13 | Lane | | n/a | TAIC | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC242 | Maverik | H061 | 6/22/13 | Lane | | | Caltrop | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Approved | No Hot Slide needed | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 1/29/13 | 1/29/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 57' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC244 | Sprint Spectrum | H062 | 5/4/13 | Lane | | | Caltrop | Yes | 12/7/12 | 5/29/13 | Approved | n/a | Yes | 2/11/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 101' | Monopole | 3 | 6 | 3 | O | S/O | Concrete Pad w/ I-Beam | 5/30/13 | 5/30/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL03XC246 | Flinders Trucking | H063 | 4/25/13 | Lane | 3/4/13 | | Caltrop | Yes | 12/12/12 | 5/20/13 | Approved | n/a | Yes | 2/13/13 | 5/20/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 4/18/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | | 100A | N | Y | Daren Holt | Chris E. |
| SL03XC248 | Lori Riddle | H064 | 5/29/13 | Lane | | | Caltrop | Yes | 12/12/12 | 5/20/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 61' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC250 | Frampton | H065 | 4/28/13 | Lane | 2/20/13 | Yes | Caltrop | Yes | 12/12/12 | 5/20/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 1/29/13 | 1/29/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 62' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC252 | OMS Diesel | H066 | 5/27/13 | Lane | | | Caltrop | Yes | 12/14/12 | 5/29/13 | Approved | n/a | Yes | 2/13/13 | 5/31/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 101' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC254 | All Steel FAB | H067 | 5/27/13 | Lane | | | Caltrop | Yes | 1/16/13 | 5/29/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/29/13 | 1/29/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC256 | Anderson Truss | H068 | 5/27/13 | Lane | | | Caltrop | Yes | 12/31/12 | 6/7/13 | Approved | n/a | Yes | 2/13/13 | 6/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 150H | 150H | 150H | n/a | 1/29/13 | 1/29/13 | 6/15/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 6 | 9 | 6 | O | S/O | Concrete Pad w/ I-Beam | 6/15/13 | 6/16/13 | | | | | 100 A | Y | N | Daren Holt | n/a |
| SL03XC258 | B&B Auto Body | H069 | 5/7/13 | Lane | | | Caltrop | Yes | 12/12/13 | 5/29/13 | Approved | n/a | Yes | 2/13/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC260 | Sunburst Auto | H070 | 6/17/13 | Lane | | 3/19/13 | Caltrop | Yes | 12/17/12 | 6/14/13 | Approved | n/a | Yes | 1/31/13 | 6/14/13 | Approved | n/a | No | n/a | Dez | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 6/15/13 | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 6/15/13 | 6/16/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC262 | Cottonwood Corp. | H205 | 7/29/13 | Lane | | 6/10/13 | Smith Hyatt | Yes | 3/12/13 | 6/14/13 | Approved | n/a | Yes | 3/12/13 | 6/14/13 | Approved | New NV antennas to be placed on existing empty wall mounts. | No | n/a | Dez | Utah | Single Outdoor | 195 | 105 | 255 | n/a | 1/29/13 | 1/29/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC264 | Ferguson Canyon | H206 | 3/23/13 | Lane | 2/11/13 | | Smith Hyatt | Yes | 6/3/13 | 4/30/13 | Approved | Mount Structural is showing the Beta mount (pole) is failing and needs to be replaces with a new 3” pipe. Pipe needs to be ordered - Correct information was provided, see SA and MA | Yes | 6/3/13 | 6/3/13 | Approved | Mount Structural is showing the Beta mount (pole) is failing and needs to be replaces with a new 3” pipe. Pipe needs to be ordered - Correct information was provided please see the MA & SA. | No | Mount is Failing - Corrective measures were given for this site. Please see the SA & MA. | Nick | Utah | Single Outdoor | 105 | 240 | 165 | n/a | 1/29/13 | 1/29/13 | | | Mary | | Non-Tower | | | Nick | 3 | 10' | 3 Steel Poles | 3 | 6 | 6 | O | S/O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 100 A | N | Y | Daren Holt | n/a | | | 4/9/13 |
| SL03XC268 | Assembly of God | H207 | 6/7/13 | Lane | | n/a | Smith Hyatt | Yes | 3/20/13 | 6/14/13 | Rejected/Failed | Interim failed at 176.2%. Final failed at 166.3%. Tower shaft failed from 0-65'. Base plate failed. Base foundation structural failed. Not identifing the 2 existing mounts and the third one that will be installed. | No | n/a | 6/14/13 | Failed | Needs 6 position collar mount w/3 dual standoff mounts. | Yes | Need a letter stating the mount can withstand the load. | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC270 | U.S. Satelite | H208 | 3/20/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 1/2/13 | 1/2/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 100' | Self Support | 3 | 6 | 4 | O | S/O | Concrete Pad w/ I-Beam | 3/26/13 | 3/26/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 4/24/13 |
| SL03XC272 | Kramer Construction | H071 | 4/22/13 | Lane | 3/8/13 | | Caltrop | Yes | 12/19/12 | 5/21/13 | Approved | n/a | Yes | 1/31/13 | 5/21/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 1/29/13 | 1/29/13 | 4/18/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | | 100A | N | Y | Daren Holt | Steve Mann |
| SL03XC274 | Union Woods | H209 | 6/24/13 | Lane | 4/5/13 | | Smith Hyatt | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 165 | 165 | 90 | n/a | 1/29/13 | 1/29/13 | | | Mary | | Non-Tower | | | Nick | 3 | 95' | Rooftop | 3 | 6 | 3 | I | S/O | Shelter | 5/3/13 | 5/3/13 | | | | Need to order consolidation antennas | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC276 | Flat Iron Mesa | H072 | 6/10/13 | Lane | | 2/28/13 | Caltrop | Yes | 12/10/12 | 6/18/13 | Approved | N/A | Yes | 1/31/13 | 6/18/13 | Approved | No hot slide needed. Possible consolidation. Check drawings. | No | n/a | Dez | Utah | | | | | | | | | | | | | | | Nick | 3 | 96' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 6/19/13 | 6/19/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC278 | Towne Storage | H073 | 5/30/13 | Lane | 3/15/13 | | Caltrop | Yes | 1/7/13 | 5/30/13 | Rejected | SA was done on a 10' mount and we speced a 4' mount. | Yes | 1/31/13 | 5/30/13 | Rejected | MA was done on a 10' mount and we speced a 4' mount. | Yes | Need a letter approving the 4' mount. | Nick | Utah | Single Outdoor | 180 | 180 | 180 | n/a | 1/29/13 | 1/29/13 | | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC280 | Karen Poulsen | H074 | 4/21/13 | Lane | 3/8/13 | | Caltrop | Yes | 1/11/13 | 5/8/13 | Approved | No Hot Slide needed | Yes | 2/6/13 | 5/31/13 | Approved | No Hot Slide needed | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 1/29/13 | 1/29/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 59' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC282 | Hand Cart Park | H075 | 5/7/13 | Lane | | | Caltrop | Yes | 12/4/12 | 5/21/13 | Approved | n/a | Yes | 1/28/13 | 5/21/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC284 | Fire Station #26 | H076 | 4/16/13 | Lane | 2/26/13 | | Caltrop | Yes | 12/5/12 | 5/21/13 | Approved | n/a | Yes | 1/28/13 | 5/21/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | N | Daren Holt | Steve Mann | | | 6/6/13 |
| SL03XC286 | Beehive Storage | H077 | 6/11/13 | Lane | | | Caltrop | Yes | 1/17/13 | 5/31/13 | Approved | n/a | Yes | 2/6/13 | 5/31/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 2/6/13 | 2/6/13 | 5/31/13 | | Mary | | Tower | | | Nick | 3 | 68' | Monopole | 3 | 6 | 4 | I | S/O | Concrete Pad w/ I-Beam | 5/31/13 | 5/31/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC288 | Sand Lot | H078 | n/a | Lane | | n/a | ERROR:#N/A | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL03XC290 | Hand Tank | H079 | 9/9/13 | Lane | | | Caltrop | Yes | 1/10/13 | 6/7/13 | Approved | Interim Fails at 107.0%, Final passes at 103.4% | Yes | 2/8/13 | 6/7/13 | Approved | n/a | No | Install a 10' T-Boom | Nick | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 2/9/13 | 2/9/13 | | | Mary | | Tower | | | Nick | 3 | 92' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 6/15/13 | 6/16/13 | | | | Installing dual poistion stand off mount | 100 A | N | N | Daren Holt | Steve Mann |
| SL03XC292 | Taylor Property | H080 | 5/7/13 | Lane | | | Caltrop | Yes | 12/6/12 | 5/21/13 | Approved | n/a | Yes | 2/6/13 | 5/21/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 2/6/13 | 2/6/13 | 5/28/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann | | | 6/5/13 |
| SL03XC294 | Bonnoco | H081 | 11/17/13 | Lane | | | Caltrop | Yes | 12/5/12 | 5/24/13 | Approved | n/a | Yes | 2/6/13 | 5/24/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC296 | Crescent Park | H082 | 9/9/13 | Lane | | | Caltrop | Yes | 12/7/13 | 6/7/13 | Failed | Fails at Interim at 126.1% and Fails at Final at 115.8% - Base plate needs to be modified. Upgrades are to be provided. | Yes | 2/6/13 | 6/7/13 | Approved | n/a | Yes | Need specifics given for beefup to base plate and achors. | Nick | Utah | Single Outdoor | 255 | 255 | 255 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 6/15/13 | 6/16/13 | | | | Need to run over 150' of conduit, under concert, parking lot and through a park. Will need to band the tower. | 100 A | N | Y | Daren Holt | n/a |
| SL03XC298 | Bell Canyon Park | H083 | 7/30/13 | Lane | | | Caltrop | Yes | 1/11/13 | 5/24/13 | Failed | Site Fails both Interim and Final. SA is ran for a 10' T-Arm and the CD is showing a standoff coming off the existing mass pipe. We need to use a 30" x 19" dual position standoff mount. | No | n/a | 5/31/13 | n/a | No MA provided at this time | Yes | Need a proper break down on everything that needs to be done to upgrade the site | Nick | Utah | Single Outdoor | 330 | 330 | 330 | n/a | 2/9/13 | 2/9/13 | | | Mary | | Tower | | | Nick | 3 | 98' | Monopole | 3 | 6 | 3 | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC300 | Glenmoor Golf Course | H084 | 8/5/13 | Lane | | | Caltrop | Yes | 1/3/13 | 6/7/13 | Rejected | CD shows a 40" mount and CC ran it for a generic 10' mount and the MA ran for a 12' 6". We need a leet stating we are clear with the 40" mount | Yes | 2/8/13 | 6/7/13 | Rejected | CD shows a 40" mount and CC ran it for a generic 10' mount and the MA ran for a 12' 6". We need a leet stating we are clear with the 40" mount | No | Need a L of C to approve the 40" mount we are showing in the CD. | Nick | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC302 | Equestrian Park | H085 | 7/7/13 | Lane | | 3/9/13 | Caltrop | Yes | 12/7/12 | 6/14/13 | Failed | Intirim failed at 119.9%. Final Failed at 108.5%. Further engineering and detailing is required to design the necessary modifications. Anchor rods at 0' require modifications. Foundation is significant. | Yes | 2/6/13 | 6/14/13 | Approved | n/a | No | n/a | Dez | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 6/16/13 | 6/16/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC304 | Carolyn White | H086 | 5/30/13 | Lane | | | Caltrop | Yes | 12/7/12 | 5/21/13 | Approved | n/a | Yes | 2/6/13 | 5/21/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 90' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann | | | 6/5/13 |
| SL03XC306 | Ron Raddon | H210 | 4/24/13 | Lane | | | Smith Hyatt | Yes | 5/23/13 | 5/23/13 | Approved | Approved - received updated information | Yes | 2/22/13 | 5/22/13 | Approved | Approved by Scott Giles | Yes | Need a letter verifing everything is good. No Conduit available, must install new conduit across the parking lot, under asphalt - Signed off and approved. | Nick | Utah | Single Outdoor | 255 | 150 | 255 | n/a | 2/7/13 | 2/7/13 | | | Mary | | Tower | | | Nick | 3 | 25' | Rooftop | 3 | 6 | 4 | O | S/O | Concrete Pad | 5/3/13 | 5/3/13 | | | | No available conduit, need to run 3 new conduits across the parking lot under the asphalt, need to order 3 consolidation antennas | 100 A | N | Y | Daren Holt | Steve Mann | | | 4/27/13 |
| SL03XC308 | Taylorsville Collocate | H211 | 8/8/13 | Lane | | | Smith Hyatt | Yes | 4/25/13 | 6/14/13 | Passed | N/A | No | N/A | N/A | N/A | No MA provided at this time | No | Owner approved drawings did not reflect correct RAD center. They've been redlined and approved by RF. | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC310 | Riverton Park | H087 | 9/17/13 | Lane | | | Caltrop | Yes | 12/7/13 | 5/13/13 | Approved | n/a | Yes | 2/6/13 | 5/30/13 | Approved | n/a | No | No Hot Slide needed | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Concrete Pad | 5/28/13 | 5/28/13 | | | | | 100 A | N | N | Daren Holt | n/a |
| SL03XC312 | Petersen Marine | H088 | 5/28/13 | Lane | | | Caltrop | Yes | 12/7/12 | 5/31/13 | Approved | n/a | Yes | 2/8/13 | 5/31/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 2/6/13 | 2/6/13 | 5/31/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 6/16/13 | 6/16/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC314 | Shelby | H089 | 5/31/13 | Lane | | | Caltrop | Yes | 12/7/12 | 5/10/13 | Approved | n/a | Yes | 2/8/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 165 | 165 | 165 | n/a | 2/6/13 | 2/6/13 | 5/10/13 | | Mary | | Tower | | | Nick | 3 | 127' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/10/13 | 5/10/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC402 | Trans West Auto | H090 | 4/17/13 | Lane | 3/5/13 | | Caltrop | Yes | n/a | 5/2/13 | Approved | n/a | Yes | n/a | 5/2/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 6 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC404 | Highland Water | H091 | 4/2/13 | Lane | 2/19/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/6/13 | 2/6/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 94' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC406 | Canyon Road Tower | H212 | 4/29/13 | Lane | | | Smith Hyatt | Yes | 3/13/13 | 6/16/13 | Approved | Cool cell cabinet platform needs to be removed. | Yes | 3/13/13 | 6/16/13 | Approved | The wall mount on sector A has a cosmetic issue. The flexing of the EFIS exterior finish is cracking in
the area of the mount plate. Over time the exterior finish will fail and spall. We recommend adding a
single Valmont slider bracket near the top of the mast to reduce the flexing. | No | Has a pipe mount planned in Sector Gamma. | Dez | Utah | | | | | | | | | | | | | | | | | | Rooftop | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL03XC408 | Waymon | H092 | 5/17/13 | Lane | | | Caltrop | Yes | 12/5/12 | 5/29/13 | Approved | n/a | Yes | 2/8/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 2/6/13 | 2/6/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC410 | JJG Investments | H213 | 5/15/13 | Lane | | | Smith Hyatt | Yes | 3/1/13 | 6/16/13 | Approved | N/A | Yes | 3/1/13 | 6/16/13 | Approved | N/A | No | Owner Approved drawings do not reflect 4 sectors. Plus they show a pipe mount. MA reflects four sectors. | Dez | Utah | | | | | | | | | | | | | | | | | | Rooftop | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC412 | Smart Silo | H214 | 3/12/13 | Lane | 2/4/13 | | Smith Hyatt | Yes | 6/1/13 | 6/5/13 | Approved | SA has passed and been uploaded to Siterra. | Yes | 6/1/13 | 6/5/13 | Approved | MA is approved and uploaded | No | n/a | Nick | Utah | Single Outdoor | 135 | 165 | 135 | 165 | 2/7/13 | 2/7/13 | | | Mary | | Tower | | | Nick | 4 | 80' | Silo | 4 | 8 | 4 | O | O | Steel Platform | | | | | | sent to Mary to look at | 100 A | Y | Y | Daren Holt | n/a | | | 4/29/13 |
| SL03XC414 | Mangum | H215 | 6/2/13 | Lane | | | Smith Hyatt | No | n/a | 6/16/13 | n/a | No SA provided at this time. | No | n/a | 6/16/13 | n/a | No MA provided at this time | No | N/A | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC416 | Peck Sons | H216 | 5/30/13 | Lane | | | TAIC | Yes | n/a | 5/1/13 | Rejected | Smoke Stack - Mount analysis wasn’t ran to do a whirligig (Stand antennas 3’ off the existing mass pipe) - mount analysis was ran for consolidation, but the weight of the RRUs was not included. Wet Stamp CD needs to be corrected or Red Lined for construction. Equipment structural was ran for Hot Swap and not a 2 - Step. | Yes | n/a | 5/14/13 | Rejected | Smoke Stack - Mount analysis wasn’t ran to do a whirligig (Stand antennas 3’ off the existing mass pipe) - mount analysis was ran for consolidation, but the weight of the RRUs was not included. Wet Stamp CD needs to be corrected or Red Lined for construction. Equipment structural was ran for Hot Swap and not a 2 - Step. | Yes | If you can get a letter, stating everything is good, we can sign off. (Nick’s reply - First this is a Hy-Cap Site and there are 2 antennas and 3 RRUs per sector, calculations isn’t correct. Nothing is showing the weight of the standoff from the existing mass pipe or the weight of the existing antennas. This is need to provide clear and correct information. - Eqpt - Certified Letter stating everything is in good standing at the Interim, will need to be provided before Construction can begin.) | Nick | Utah | Single Outdoor | 240H | 240H | 240H | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | | Smokestack | 6 | 9 | 6 | | | | | | | | | | | | | Daren Holt | n/a | | | 4/23/13 |
| SL03XC418 | Tooele City Fire | H093 | 4/24/13 | Lane | 3/13/13 | | Caltrop | Yes | 12/11/12 | 5/21/13 | Approved | n/a | Yes | 2/11/13 | 5/21/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 120 | 120 | 120 | n/a | 2/7/13 | 2/7/13 | 4/18/13 | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 3 | 6 | 5 | O | S/O | Concrete Pad | 4/18/13 | 4/18/13 | | | | | 100A | N | Y | Daren Holt | Chris E. |
| SL03XC420 | Thad Beal | H094 | 5/5/13 | Lane | | | Caltrop | Yes | 12/10/12 | 5/31/13 | Approved | n/a | Yes | 2/11/13 | 5/31/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/7/13 | 2/7/13 | 5/31/13 | | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 6/16/13 | 6/16/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC422 | Lindon Park | H095 | 4/15/13 | Lane | 3/4/13 | | Caltrop | Yes | 12/12/12 | 5/31/13 | Approved | n/a | No | n/a | 5/31/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Single Outdoor | 150 | 150 | 150 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 97' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | N | Daren Holt | n/a |
| SL03XC424 | Seven Peaks | H217 | 4/29/13 | Lane | | | Smith Hyatt | Yes | 6/3/13 | 6/3/13 | Approved | SA has been corrected and shows what needs to be done | Yes | 6/3/13 | 6/3/13 | Approved | MA has been corrected and approved | No | SA & MA are corrected and reflect what needs to be done. | Nick | Utah | Single Outdoor | 165 | 165 | 165 | n/a | 2/7/13 | 2/7/13 | | | Mary | | Tower | | | Nick | 3 | | Water Slide/ RFT | 3 | 6 | 4 | O | S/O | | | | | | | | | | | Daren Holt | n/a | | | 4/29/13 |
| SL03XC426 | Cherrywood Sunstation | H096 | 2/13/13 | Lane | 2/11/13 | | Caltrop | Yes | n/a | 5/8/13 | Approved | n/a | Yes | n/a | 5/8/13 | Approved | Hot slide not needed | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | Could be a temporary DUAL, no room until decomm. | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | N | Daren Holt | Steve Mann |
| SL03XC428 | Eagle Ridge | H097 | 6/4/13 | Lane | | CD redlined on 6/13/13 | Caltrop | Yes | 1/19/13 | 6/13/13 | Approved | Interim fails at 114%. Final Passes at 101.8%. | Yes | 2/8/13 | 6/13/13 | Approved | N/A | No | n/a | Dez | Utah | Single Outdoor | 75 | 75 | 75 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 22'/18'/22' | Wooden Pole | 3 | 6 | 5 | O | S/O | Steel Platform | 6/16/13 | 6/16/13 | | | | | 100 A | N | Y | Daren Holt | n/a |
| SL03XC430 | Richard Gornichec | H098 | 2/15/13 | Lane | 2/15/13 | | Caltrop | Yes | 12/17/12 | 6/17/13 | Approved | N/A | Yes | 2/8/13 | 6/17/13 | Approved | No Hot Slide needed | No | N/A | Dez | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | Could be a temporary DUAL, no room until decomm. | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC432 | Orem Firestation | H099 | 2/15/13 | Lane | 2/19/13 | | Caltrop | Yes | 12/14/13 | 6/17/13 | Approved | N/A | Yes | 2/8/13 | 6/17/13 | Approved | No Hot Slide needed | No | N/A | Dez | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | Could be a temporary DUAL, no room until decomm. | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC434 | Fruit Stand | H218 | 4/29/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/6/13 | Approved | Approved w/ Consolidation | Yes | n/a | 5/6/13 | Approved | Approved w/ Consolidation | No | n/a | Nick | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 2/6/13 | 2/6/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 35' | Rooftop | 3 | 6 | 3 | O | S/O | Shelter | 5/9/13 | 5/9/13 | | | | | 200 A | N | N | Daren Holt | Chris E. | | | 4/30/13 |
| SL03XC436 | Utah County EQ/Richard Gornichec | H100 | 2/13/13 | Lane | 2/11/13 | | Caltrop | Yes | n/a | 5/8/13 | Approved | n/a | Yes | n/a | 5/8/13 | Approved | Hot slide not needed | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | Could be a temporary DUAL, no room until decomm. | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC438 | David Gardner | H219 | 6/20/13 | Lane | | | Fullerton | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | n/a | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL03XC440 | EXCEL Graphics | H101 | 5/30/13 | Lane | | | Caltrop | Yes | 12/11/12 | 5/23/13 | Approved | n/a | Yes | 2/11/13 | 5/23/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 5/29/13 | 5/29/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC442 | Dr. Fullmer | H102 | 3/21/13 | Lane | 2/20/13 | | Caltrop | Yes | 12/14/12 | 5/14/13 | Approved | n/a | Yes | 2/11/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 98' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/26/13 | 3/26/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC444 | Evan Trucking | H103 | 3/14/13 | Lane | 2/20/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | Could be a temporary DUAL, no room until decomm. | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC446 | Bird Storage | H104 | 3/14/13 | Lane | 2/15/13 | | Caltrop | Yes | 12/13/12 | 5/10/13 | Approved | n/a | Yes | 2/11/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | Could be a temporary DUAL, no room until decomm. | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. | | | 5/30/13 |
| SL03XC448 | Mapleton City Park | H105 | 2/15/13 | Lane | 2/15/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/8/13 | 2/8/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 96' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/26/13 | 3/26/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC450 | Industrial Park | H106 | 4/1/13 | Lane | 3/14/13 | | Caltrop | Yes | 12/15/12 | 5/10/13 | Approved | n/a | Yes | 2/11/13 | 5/10/13 | Approved | CD shows Hot Slide and the wrong Mount is shown on the Final. Hot Slide not needed | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 2/9/13 | 2/9/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 79' | Monopole | 3 | 6 | 5 | O | S/O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann | | | 5/30/13 |
| SL03XC452 | East Bench | H107 | 4/8/13 | Lane | 2/28/13 | | Caltrop | Yes | 12/15/12 | 5/23/13 | Approved | n/a | Yes | 2/11/13 | 5/23/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC454 | G&W Investments | H108 | 4/8/13 | Lane | 3/5/13 | | Caltrop | Yes | 12/17/12 | 5/23/13 | Approved | n/a | Yes | 2/11/13 | 5/23/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/9/13 | 2/9/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL03XC456 | Salem's Lot | H109 | 5/7/13 | Lane | | | Caltrop | Yes | 12/7/12 | 5/10/13 | Approved | n/a | Yes | 2/11/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 2/7/13 | 2/7/13 | 5/10/13 | | Mary | | Tower | | | Nick | 3 | 95' | Monopole | 3 | 6 | 4 | O | S/O | Steel Platform | 5/10/13 | 5/10/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL03XC458 | Payson City | H110 | 6/29/13 | Lane | | | Crown | No | n/a | 6/12/13 | n/a | no SA available in Siterra | Yes | 2/11/13 | 6/12/13 | Approved | No Hot Slide needed | No | CDs redlined for A-2 platform corrections | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL13XC572 | Brickyard | H220 | 5/25/13 | Lane | | | Smith Hyatt | Yes | 3/3/13 | 6/4/13 | Approved | n/a | Yes | 6/10/13 | 6/11/13 | Approved | MA has been corrected and approved | No | Antenna swap out due to LL not allowing any additional material on the site. | Nick | Utah | Single Outdoor | 105 | 120 | 90 | n/a | 2/8/13 | 2/8/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | O | S/O | | | | | | | | | | | Daren Holt | n/a |
| SL13XC574 | Van Winkle | H221 | 4/30/13 | Lane | | | Smith Hyatt | Yes | 6/1/13 | 6/3/13 | Approved | SA was corrected and RRUs were calcuated, also the mass pipe size was corrected to 2 1/2" | Yes | 6/1/13 | 6/3/13 | Approved | MA was corrected and RRUs were calcuated, also the mass pipe size was corrected to 2 1/2" | Yes | SA & MA is approved and everything is corrected. | Nick | Utah | Single Outdoor | 240 | 315 | 240 | n/a | 2/6/13 | 2/6/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | | | | | | | | | | | | | Daren Holt | n/a | | | 4/29/13 |
| SL13XC580 | Bicycle City | H222 | 6/8/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL13XC582 | Eaglewood | H111 | 7/26/13 | Lane | | | Crown | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL13XC584 | Unversity of Utah Hosptial | H223 | 4/13/13 | Lane | | | Smith Hyatt | Yes | 6/1/13 | 6/3/13 | Approved | SA was corrected for the calculation of the 6 RRUs | Yes | 6/1/13 | 6/3/13 | Approved | MA was corrected for the weight of the 6 RRUs. | Yes | SA & MA were corrected and approved. | Nick | Utah | Single Outdoor | 315 | 75 | 135 | n/a | 2/6/13 | 2/6/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | | | | | | | | | | | | | Daren Holt | Shane M. | | | 5/15/13 |
| SL13XC588 | Olympus Collocate | H224 | n/a | Lane | | | ERROR:#N/A | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | relocation site, no active site in Siterra, no data | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL13XC601 | Parley's Summit | H226 | 3/13/13 | Lane | 1/16/13 | | Smith Hyatt | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 2/4/13 | 2/4/13 | | Can be Dual Indoor, inside of an old silo/tank | Mary | | Non-Tower | | | Nick | 3 | 26' | Silo | 3 | 6 | 6 | I | S/O | Shelter | 5/3/13 | 5/3/13 | | | | | 100 A | N | Y | Daren Holt | n/a | | | 4/17/13 |
| SL13XC602 | Kimball Junction | H227 | 3/13/13 | Lane | 2/4/13 | | Smith Hyatt | Yes | 3/5/13 | 5/23/13 | Approved | ran for a 2 - Step on the Equipment, nothing ran for the building - SA is approved. | Yes | 5/22/13 | 5/23/13 | Approved | ran for colsolidation, MA states Skid Mount and it doesn't call out removing all the existing CDMA antennas and consolidating them to 3 antennas. - Approved - received Certified. 05/23/13 | Yes | verifing there was a structural ran on the building. - received letter - 5/23/13 | Nick | Utah | Single Outdoor | 105 | 105 | 180 | n/a | 2/8/13 | 2/8/13 | 5/28/13 | Underground VAULT, NO ROOM, BBU will have to come out | Mary | | Tower | | | Nick | 3 | 35' | Rooftop | 3 | 6 | 4 | I | S/O | Bunker Shelter | 5/28/13 | 5/28/13 | | | | | 100 A | N | Y | Daren Holt | Steve Mann |
| SL13XC603 | Quarry Mountain | H112 | 6/4/13 | Lane | | | Caltrop | Yes | 6/3/13 | 6/6/13 | Approved | SA has been corrected and approved | Yes | 6/3/13 | 6/6/13 | Approved | MA has been corrected and approved | No | n/a | Nick | Utah | Single Indoor | 135 | 135 | 135 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 65' | Monopole | 3 | 6 | 3 | I | S/I | Shelter | 5/9/13 | 5/9/13 | | | | Need to core drill 4 holes | 100 A | N | N | Daren Holt | Clay Schutzer |
| SL13XC604 | Yarrow Hotel | H228 | 3/30/13 | Lane | 2/25/13 | | Smith Hyatt | Yes | 5/22/13 | 5/23/13 | Approved | Equipment must be a 2 - Step, Tower - states standoffs can only be 12" but doesn't include the weight of standoffs and 12" isn't enough room - Hot Swap is palnned, cabinets will be set as a 2 - Step. | Yes | 5/23/13 | 5/23/13 | Approved | Hot Swap on Alpha nad Gamma and consolidate the Beta antennas. All RRUs will be mounted on the inside of the tower on the roof. | No | n/a | Nick | Utah | Outdoor | 105 | 105 | 105 | n/a | 12/31/12 | 12/31/12 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 60' | Rooftop | 3 | 6 | 4 | O | O | Steel Platform | 5/28/13 | 5/28/13 | | | | | 200 A | N | Y | Daren Holt | Clay Schutzer | | | 5/24/13 | | Beta will be consolidated on the back of the wall and Alpha and Gamma will be hot swaps. All RRUs will be mounted inside the tower. |
| SL13XC605 | Caledonian | H229 | 3/8/13 | Lane | 1/10/13 | | Smith Hyatt | Yes | 5/22/13 | 5/23/13 | Approved | Platform Structural was ran for a Hot Swap only, No Interim config, Structural states one cabinet one cabinet off and one than can go on. Need to pull the existing BBU before setting MMBS - Mount analysis shows installing 3 new cantilever mounts to the side of the building, not standing pipes off the existing cantilever mount - Structural for equipment is good to go to set the cabinets. - Installing 3 new cantilever brackets inside and out for the new antennas and RRUs. | Yes | 5/22/13 | 5/23/13 | Approved | Installing 3 new cantilever brackets inside and out for the new antennas and RRUs. Install 4" boot on both sides of the wall behind the antennas and run the jumpers from the RRUs inside to the antennas mounted on the wall outside. Remove CDMA antennas and brackets at the end. | No | n/a | Nick | Utah | Single Outdoor | 255 | 240 | 255 | n/a | 2/6/13 | 2/6/13 | | Indoor Site | Mary | | Non-Tower | | | Nick | 3 | 58' | Rooftop | 3 | 6 | 3 | I | S/O | Shelter | 5/28/13 | 5/28/13 | | | | | 100 A | N | N | Daren Holt | n/a | | | 4/15/13 | | | Will need to core dril 7 holes and install 6 cantilever mounts, 3 inside and 3 out. |
| SL17XC651 | Doctor Rooftop | H235 | 3/21/13 | Lane | 2/18/13 | | Smith Hyatt | Yes | 5/23/13 | 5/24/13 | Approved | Structural reflexs what is being done on the CD. Install new NV antennas on the middle position, change out the support arms on all three sectors. Eqpt okay to set. | Yes | 5/23/13 | 5/24/13 | Approved | Structural reflexs what is being done on the CD. Install new NV antennas on the middle position, change out the support arms on all three sectors. Eqpt okay to set. | No | SA & MA match the BOM and CD. | Nick | Utah | Outdoor | 195 | 105 | 150 | n/a | 12/31/12 | 12/31/12 | | | Mary | | Non-Tower | | | Nick | 3 | 63' | Rooftop | 3 | 6 | 3 | O | S/O | Steel Platform | 3/26/13 | 3/26/13 | | | | | 100 A | N | N | Daren Holt | n/a | | | 4/18/13 |
| SL17XC652 | Alley | H116 | 4/24/13 | Lane | 3/6/13 | | Caltrop | Yes | 12/19/12 | 6/12/13 | Approved | | Yes | 2/11/13 | 6/12/13 | Approved | Handrail 12.6" required for twist and sway | No | n/a | Craig | Utah | Single Outdoor | 105 | 105 | 105 | n/a | 2/9/13 | 2/9/13 | 4/18/13 | | Mary | | Tower | | | Nick | 3 | 77' | Monopole | 3 | 6 | 3 | O | S/O | Steel Platform | 4/18/13 | 4/18/13 | | | | | 200A | N | N | Daren Holt | n/a |
| SL17XC653 | Ball Park | H117 | 7/26/13 | Lane | | | Crown | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | no documents in Siterra | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL17XC654 | Marriot | H236 | 5/7/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/8/13 | Approved | Ran for antennas and RRUs to mounted on the wall | Yes | n/a | 5/8/13 | Approved | Mount analysis is ran for 3 new cantilever mounts to be installed and the new antennas and RRUs to be installed on the new Mounts. | No | CD shows standoffs off the existing mass pipes. | Nick | Utah | Single Outdoor | 105 | 120 | 120 | n/a | 2/9/13 | 2/9/13 | | | Mary | | Tower | | | Nick | 3 | 117' | Rooftop | 3 | 6 | 5 | O | S/O | Penthouse on I-Beams | 5/9/13 | 5/9/13 | | | | | 200A | N | Y | Daren Holt | Chris E. |
| SL17XC655 | Golf Course Orchard | H237 | 5/14/13 | Lane | | | Fullerton | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | n/a | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL25XC170 | Keith Potter Relocation | H238 | 8/3/13 | Lane | 3/6/13 | 3/6/13 | Crown | Yes | 3/7/13 | 6/3/13 | Approved | n/a | No | n/a | 6/3/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | | | | | | | | | | Mary | | Tower | | | Nick | 3 | 101' | Monpole | 3 | 6 | 3 | | | | | | | | | | | | | Daren Holt | n/a |
| SL25XC288 | n/a | n/a | n/a | n/a | n/a | n/a | ERROR:#N/A | No | n/a | 4/30/13 | Stop Work Site | n/a | No | n/a | 4/30/13 | Stop Work Site | n/a | No | n/a | Nick | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | Jacob Walker | n/a | | | | | n/a | n/a |
| SL25XC588 | n/a | n/a | n/a | n/a | n/a | n/a | ERROR:#N/A | No | n/a | 4/30/13 | Stop Work Site | n/a | No | n/a | 4/30/13 | Stop Work Site | n/a | No | n/a | Nick | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | Jacob Walker | n/a | | | | | n/a | n/a |
| SL29XC106 | Building 87 | H239 | 3/9/13 | Lane | 2/11/13 | | TAIC | Yes | 1/23/13 | 5/13/13 | Approved | n/a | Yes | 3/31/13 | 5/13/13 | Approved | n/a | No | No Hot Slide Needed | Nick | Utah | Outdoor | 120 | 120 | 120 | n/a | 1/31/13 | 1/31/13 | 3/25/13 | | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 100 A | N | N | Jacob Walker | Clay Schutzer | | | 5/9/13 |
| SL29XC107 | Layton Hills Western Wireless | H240 | 7/17/13 | Lane | | | TAIC | No | n/a | 6/12/13 | n/a | no SA available in Siterra | No | n/a | 6/12/13 | n/a | No MA provided at this time | No | n/a | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL29XC111 | Sahara Inc. | H241 | 3/30/13 | Lane | 1/24/13 | | TAIC | Yes | n/a | 5/7/13 | Approved | ran for consolidation | Yes | n/a | 5/7/13 | Approved | ran for consolidation | No | n/a | Nick | Utah | Outdoor | 120 | 75 | 75 | n/a | 2/7/13 | 2/7/13 | 3/28/13 | | Mary | | Non-Tower | | | Nick | 3 | 48' | Rooftop | 3 | 6 | 4 | I | O | Shelter w/ I-Beams | 3/28/13 | 3/28/13 | | | | Need to order 3 additional NV antennas | 200 A | N | N | Jacob Walker | n/a | | | 5/1/13 |
| SL29XC122 | Utah LP Gas | H118 | 5/22/13 | Lane | | 3/21/13 | Crown | Yes | 1/2/13 | 6/13/13 | Approved | n/a | Yes | 2/11/13 | 6/13/13 | Approved | n/a | No | n/a | Craig | Utah | Outdoor | 105 | 105 | 105 | n/a | 2/7/13 | 2/7/13 | 6/16/13 | | Mary | | Tower | | | Nick | 3 | 58' | Monopole | 3 | 6 | 4 | O | O | Steel Platform | 6/16/13 | 6/16/13 | | | | | | | | Jacob Walker | n/a |
| SL29XC141 | L&N Uniform | H242 | 5/4/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/7/13 | Approved | n/a | Yes | 6/3/13 | 6/6/13 | Approved | MA was corrected and approved | No | MA was corrected and provided | Nick | Utah | Outdoor | 150 | 150 | 150 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 78' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden |
| SL29XC149 | City Property | H119 | 6/16/13 | Lane | | 3/28/13 | Crown | Yes | 12/15/12 | 6/13/13 | Approved | n/a | No | n/a | 6/13/13 | n/a | No MA provided at this time | No | n/a | Craig | Utah | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL29XC152 | Johnson Trucking II | H120 | 4/30/13 | Lane | | | Caltrop | Yes | 1/29/13 | 5/29/13 | Approved | n/a | Yes | 2/11/13 | 5/29/13 | Approved | Need to install a 12' Hand Rail | No | n/a | Nick | Utah | Outdoor | 105 | 105 | 105 | n/a | 2/7/13 | 2/7/13 | | | Mary | | Tower | | | Nick | 3 | 55' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 200 A | N | Y | Daren Holt | n/a | | | | | Need to install a 12' hand rail |
| SL29XC159 | High School Auditorium | H243 | 5/2/13 | Lane | | | Rage | Yes | 3/12/13 | 6/13/13 | Approved | rooftop | Yes | 3/12/13 | 6/13/13 | Approved | rooftop | No | rooftop | Craig | Utah | Single Outdoor | 225 | 300 | 330 | n/a | 2/7/13 | 2/7/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | O | S/O | | | | | | | | | | | Daren Holt | n/a |
| SL33XC022 | Rogers Ranch | H121 | 6/11/13 | Lane | | | Crown | Yes | 12/11/12 | 6/12/13 | Approved | n/a | Yes | 2/11/13 | 6/12/13 | Approved | n/a | No | No hot slide required | Craig | Utah | Indoor | 105 | 105 | 105 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 38' | Monopole | 3 | 6 | 3 | I | I | Shelter | 6/16/13 | 6/16/13 | | | | | | | | Daren Holt | n/a |
| SL33XC078 | Jordanelle Point | H122 | 7/26/13 | Lane | | | Crown | No | n/a | 6/13/13 | n/a | no SA available in Siterra | No | n/a | 6/13/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL33XC132 | US West @ SR111 - Site 162 | H245 | 5/4/13 | Lane | | | Smith Hyatt | Yes | n/a | 4/29/13 | Rejected | Mount analysis ran on the wrong style mount, and the mount analysis was ran at 168’ and not 100’. Wet Stamp CD shows antennas to be mounted on the stiff arm which is wrong. Structural was ran for only 1 antenna and 1 mount existing on the tower. Structural for both need to be reran and CD needs to be corrected | Yes | 6/7/13 | 4/29/13 | Rejected | Mount analysis ran on the wrong style mount, and the mount analysis was ran at 168’ and not 100’. Wet Stamp CD shows antennas to be mounted on the stiff arm which is wrong. Structural was ran for only 1 antenna and 1 mount existing on the tower. Structural for both need to be reran and CD needs to be corrected. Need to add new mounts and consolidate the Beta sector for CDMA. | No | n/a | Nick | Utah | Outdoor | 180 | 180 | 180 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 100' | Guyed | 3 | 6 | 3 | O | O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL33XC133 | Towers - Site 164 | H123 | 5/11/13 | Lane | | | Caltrop | Yes | 1/16/13 | 5/23/13 | Approved | n/a | Yes | 2/13/13 | 5/23/13 | Approved | Need to add a 12' 6" Handrail | No | n/a | Nick | Utah | Outdoor | 150 | 150 | 150 | n/a | 2/8/13 | 2/8/13 | 5/29/13 | | Mary | | Tower | | | Nick | 3 | 103' | Monopole | 3 | 6 | 5 | O | O | Steel Platform | 5/29/13 | 5/29/13 | | | | | 100 A | N | N | Daren Holt | Steve Mann | | | | | Need to install a 12' hand rail |
| SL35XC001 | BYU/Park Plaza - Site 172 | H124 | 4/29/13 | Lane | | 3/9/13 | Crown | Yes | 1/4/13 | 6/13/13 | Rejected | Failed at Inerim at the base at 122.7%, but Passes at Final at 101.7% - SA was ran on a Monopole and not a telephone pole, also the SA was ran for a new 10' mount and we are calling out a dual stand off mount 40" x19", the MA specs a small dual 40" x 19" mount. | Yes | 2/11/13 | 6/13/13 | Approved | New antenna mounting system to replace cluster mount | Yes | SO/CDs need redlined. Wooden pole. - Need a letter stating that a 40" x 19" dual standoff mount will be sufficent on the wooden pole istead of the 10' mount the SA specs. | Craig | Utah | Outdoor | 120 | 120 | 120 | n/a | 2/8/13 | 2/8/13 | 6/16/13 | | Mary | | Tower | | | Nick | 3 | 77' | Wooden Pole | 3 | 6 | 5 | O | O | Steel Platform | | | | | | New Dual Position standoff mount 10 1/2" collar | 200 A | N | Y | Daren Holt | n/a | | | | | Wooden Pole sent a request to have a smaller mount added to the BOM. |
| SL35XC002 | PAC Butler Substation - Site 137 | H125 | 8/15/13 | Lane | | | Caltrop | Yes | 12/11/12 | 5/13/13 | Approved | n/a | Yes | 2/13/13 | 6/18/13 | Approved | N/A | No | n/a | Nick, Dez (MA) | Utah | Outdoor | 120 | 120 | 120 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 58' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/29/13 | 5/29/13 | | | | | 100 A | N | Y | Daren Holt | Chris E. |
| SL35XC003 | Bulls Eye - Site 169 | H246 | 4/29/13 | Lane | | 2/15/13 | Rage | Yes | 3/18/13 | 6/13/13 | Approved | n/a | Yes | 3/20/13 | 6/13/13 | Rejected | The MA states it was ran for 1 antenna and 2 RRUs, instead of 3 antennas and 6 RRUs. | Yes | PE Letter correcting the Verbiage will be sufficent. | Craig | Utah | Single Outdoor | 135 | 135 | 135 | n/a | 2/5/13 | 2/5/13 | 6/16/13 | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 4 | I | S/O | Shelter w/ I-Beam | 6/16/13 | 6/16/13 | | | | The Conduit should be sufficent to withhold 1 more cable per each of the 3 existing Conduit. Have CS verify to make sure. | 200 A | N | Y | Daren Holt | n/a |
| SL36XC004 | RLK Properties | H126 | 8/18/13 | Lane | | | Caltrop | Yes | 12/15/12 | 5/13/13 | Failed - Interim 109.8% and Final 109.8% | Need to make base mods | Yes | 2/13/13 | 6/14/13 | Approved | Need Namd rail for a 12' 6" mount | No | n/a | Nick | Utah | Outdoor | 135 | 135 | 135 | n/a | 2/8/13 | 2/8/13 | 5/29/13 | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/29/13 | 5/29/13 | | | | Need to order a Hand rail | 200 A | N | N | Daren Holt | n/a |
| SL36XC005 | Oak Canyon Jr High | H127 | 8/3/13 | Lane | | | Crown | No | n/a | 6/13/13 | n/a | no SA available in Siterra | No | n/a | 6/13/13 | n/a | No MA provided at this time | No | No owner approved CD uploaded to Siterra | Craig | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL36XC006 | Hogi Yogi | H128 | 5/8/13 | Lane | | | Caltrop | Yes | 1/14/13 | 6/14/13 | Approved | n/a | Yes | 3/11/13 | 6/17/13 | Approved | n/a | No | n/a | Craig | Utah | | | | | | | | | | Mary | | | | | Nick | 3 | | Monopole | 3 | 6 | 4 | | | | | | | | | | | | | Daren Holt | Steve Mann |
| SL36XC009 | Beauty Bark Trucking | H129 | 4/30/13 | Lane | | | Caltrop | Yes | 12/13/12 | 5/29/13 | Approved | n/a | Yes | 2/11/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 105 | 105 | 105 | n/a | 2/8/13 | 2/8/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 68' | Monopine | 3 | 6 | 4 | O | O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL37XC002 | E Center | H247 | 6/22/13 | Lane | | 5/28/13 | Smith Hyatt | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL37XC005 | Multi-Ethnic - Senior Housing | H249 | 4/13/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/1/13 | Approved | Equipment structural is good | Yes | n/a | 5/1/13 | Rejected | Mount analysis was not ran to capture the whirligig that the CD is showing. Mount analysis was ran for a consolidation, but it doesn’t specify the type of mount that needs to be used on the building. Need to consolidate CDMA antennas | Yes | Need a Letter stating everything is good. | Nick | Utah | Single Outdoor | 90 | 180 | 135 | n/a | 2/5/13 | 2/5/13 | | | Mary | | Tower | | | Nick | 3 | 156'/156'/162' | Rooftop | 3 | 6 | 3 | O | S/O | Steel Plaform | 5/3/13 | 5/3/13 | | | | Need to order consolidation antennas for Beta and Gamma antennas on CDMA | 200 A | N | Y | Jacob Walker | n/a | | | | | Updated BOM 6/5/13 |
| SL40XC020 | Provo High School | H250 | 6/24/13 | Lane | | | Smith Hyatt | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL40XC029 | PACX Businees Park | H251 | 5/11/13 | Lane | | | Smith Hyatt | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL40XC034 | Bridal Image | H252 | 3/29/13 | Lane | 2/11/13 | | TAIC | Yes | 4/18/13 | 5/14/13 | Approved | n/a | Yes | 4/18/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Utah | Single Indoor | 120 | 90 | 120 | n/a | 2/4/13 | 2/4/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 27' | Rooftop | 3 | 6 | 4 | I | S/I | Shelter - Closet | 3/28/13 | 3/28/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. | | | 5/15/13 |
| SL40XC052 | Magcorp | H130 | 4/6/13 | Lane | 2/28/13 | | Caltrop | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 120 | 120 | 120 | n/a | 2/7/13 | 2/7/13 | | | Mary | | Tower | | | Nick | 3 | 59' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 200 A | N | Y | Jacob Walker | n/a |
| SL40XC053 | Granger Medical | H253 | 5/7/13 | Lane | | | Smith Hyatt | Yes | 3/7/13 | 6/14/13 | Rejected | Need to calculate for weight of sled mounts. Need to remove SL54XC030 from subject line. | Yes | 3/7/13 | 6/14/13 | Yes | n/a | No | rooftop | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL40XC061 | Chelemes | H131 | 2/20/13 | Lane | 2/26/13 | | Caltrop | Yes | n/a | 5/6/13 | Approved | Add hand rails | Yes | n/a | 5/6/13 | Approved | Add Hand rails to mount | No | n/a | Nick | Utah | Outdoor | 150 | 150 | 150 | n/a | 2/9/13 | 2/9/13 | 3/25/13 | | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 4 | O | O | Steel Platform | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Jacob Walker | n/a |
| SL41XC040 | SL41XC040-C | H254 | 9/19/13 | Lane | | | TAIC | No | n/a | 6/14/13 | n/a | No SA provided at this time. | Yes | 3/31/13 | 6/14/13 | Approved | n/a | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL54XC001 | Elggren Property | H255 | 3/13/13 | Lane | 1/10/13 | | Smith Hyatt | Yes | 5/23/13 | 5/31/13 | Approved | New Structural and Mount analysis is approved, RF Approved. | Yes | 5/23/13 | 5/31/13 | Approved | New Structural and Mount analysis is approved, RF Approved | Yes | Waiting on Approval from RF.RF Approved. Received Email. | Nick | Utah | Outdoor | 105 | 105 | 210 | n/a | 2/9/13 | 2/9/13 | | Existing equipment is indoor/site is indoor | Mary | | Tower | | | Nick | 3 | 13' | Wooden Pole | 3 | 6 | 3 | I | O | Shelter w/ I-Beams | 5/28/13 | 5/28/13 | | | | Need a CS to walk and provide pictures | 200 A | N | Y | Jacob Walker | n/a | | | 4/24/13 |
| SL54XC012 | South Hills - Site 206 | H256 | 5/7/13 | Lane | | | Smith Hyatt | Yes | 3/4/13 | 6/14/13 | Rejected | Rad Center of structural at 68' vs. Rad center of CDs at 62'. Need to verify which is corrected. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL54XC013 | Big Daddy - Site 195 | H257 | 4/27/13 | Lane | | | Smith Hyatt | Yes | 1/18/13 | 5/28/13 | Approved | n/a | Yes | 6/21/13 | 6/21/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 180 | 180 | 180 | n/a | 2/6/13 | 2/6/13 | | | Mary | | Tower | | | Nick | 3 | 90' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/29/13 | 5/29/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 5/21/13 | | Need to remove 3 of the existing lines and snap-in the new hybrid cable and restack the existing lines. |
| SL54XC020 | Provo Gun Club | H258 | 4/29/13 | Lane | | | Smith Hyatt | Yes | n/a | 4/29/13 | Approved | n/a | Yes | n/a | 4/29/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 120 | 120 | n/a | n/a | 2/6/13 | 2/6/13 | 5/2/13 | | Mary | | Tower | | | Nick | 2 | 85' | Monopole | 2 | 4 | 4 | O | O | Steel Platform | 5/2/13 | 5/2/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 4/30/13 |
| SL54XC024 | Shepard's Hill | H133 | 11/16/13 | Lane | | CD needs to be corrected to show Dual position Mount | Caltrop | Yes | 1/10/13 | 6/14/13 | Approved | n/a | Yes | 2/15/13 | 6/14/13 | Approved | New antenna mounting system to replace cluster mount | No | n/a | Craig | Utah | Outdoor | 150 | 150 | n/a | n/a | 1/29/13 | 1/29/13 | | | Mary | | Tower | | | Nick | 2 | 22' | Monopole | 2 | 4 | 3 | O | O | Steel Platform | 6/16/13 | 6/16/13 | | | | New Dual Position standoff mount, need to install new conduit form Eqpt to tower, 50' through a retaining wall up the hill. | | | | Daren Holt | n/a |
| SL54XC030 | Oak Hallow Elementry | H260 | 4/27/13 | Lane | | | Smith Hyatt | Yes | 3/7/13 | 5/15/13 | Approved | n/a | Yes | 6/4/13 | 6/5/13 | Approved | MA has been corrected and approved | No | n/a | Nick | Utah | Outdoor | 90 | 165 | 225 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | | Rooftop | 3 | 6 | 4 | O | O | | | | | | | | | | | Daren Holt | n/a | | | 5/21/13 |
| SL54XC031 | Christensen Property | H134 | 3/30/13 | Lane | 2/6/13 | | Caltrop | Yes | 2/7/13 | 5/14/13 | Fails | Tower Fails at Interim at 134.6% and Fails at Final at 122.5% - Tower needs the Base plate upgraded and the tower from 0 to 15'. | No | n/a | 5/14/13 | n/a | No MA provided at this time | Yes | Verifing exactly what needs to be done. | Nick | Utah | Outdoor | 135 | 135 | 135 | n/a | 2/7/13 | 2/7/13 | | | Mary | | Tower | | | Nick | 3 | 81' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Daren Holt | Steve Mann |
| SL54XC060 | Highland Springs | H261 | 4/30/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/6/13 | Approved | n/a | Yes | n/a | 5/6/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 270 | 180 | 180 | n/a | 1/29/13 | 1/29/13 | | | Mary | | Non-Tower | | | Nick | 3 | 70' | Rooftop | 3 | 6 | 3 | O | O | Steel Platform | 5/9/13 | 5/9/13 | | | | | 200 A | N | N | Daren Holt | Chris E. | | | 4/26/13 |
| SL54XC061 | Utah Medical Products II | H136 | 7/1/13 | Lane | | | Caltrop | Yes | 12/11/12 | 5/29/13 | Fails SA | SA Fails at Interim at 134.3% and Fails at Final at 117% - Need to get information on beefing up from 0-38' and the base plate. | Yes | 2/15/13 | 5/29/13 | Approved | n/a | Yes | need a letter on what needs to be done for Beef up. | Nick | Utah | Outdoor | 120 | 120 | 120 | n/a | 2/7/13 | 2/7/13 | 5/30/13 | | Mary | | Tower | | | Nick | 3 | 75' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 5/30/13 | 5/30/13 | | | | | 200 A | N | Y | Daren Holt | n/a |
| SL54XC062 | Hampton Inn | H262 | 3/14/13 | Lane | 1/18/13 | | Smith Hyatt | Yes | 6/4/13 | 6/5/13 | Approved | SA has bee ncorrected | Yes | 6/4/13 | 6/5/13 | Approved | SA has been corrected an approved | No | Everything has been corrected and cleared. | Nick | Utah | Single Outdoor | 210 | 210 | 210 | n/a | 2/9/13 | 2/9/13 | | Existing equipment is indoor/site is indoor | Mary | | Non-Tower | | | Nick | 3 | 55' | Rooftop | 3 | 6 | 3 | I | S/I | Shelter w/ I-Beams | | | | | | Need a CS to walk and provide pictures in Steeple | 200 A | N | Y | Daren Holt | n/a |
| SL54XC063 | T-B Improvement District | H137 | 6/16/13 | Lane | | | Caltrop | Yes | 12/11/12 | 6/14/13 | Approved | Interim at 106%, final passing at 97.5 | Yes | 2/15/13 | 6/14/13 | Approved | proposed handrail to to support additional loading | No | n/a | Craig | Utah | Outdoor | 135 | 135 | 135 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Tower | | | Nick | 3 | 87' | Monopole | 3 | 6 | 3 | O | O | Steel Platform | 6/16/13 | 6/16/13 | | | | Need to install a handrail - 12' 6" - MA specs it | 200 A | N | N | Daren Holt | n/a | | | | | Need to paint to match the tower. |
| SL54XC064 | Keene Coatings | H263 | 6/24/13 | Lane | | | Smith Hyatt | Yes | 3/21/13 | 6/14/13 | Approved | n/a | No | n/a | 6/14/13 | n/a | Mo MA provided at this time | No | n/a | Craig | Utah | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL54XC065 | Centennial Building | H264 | 4/7/13 | Lane | 1/28/13 | | TAIC | No | n/a | 5/31/13 | n/a | No Structural at this time | Yes | 2/27/13 | 5/15/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 90 | 105 | 135 | n/a | 2/4/13 | 2/4/13 | | | Mary | | Non-Tower | | | Nick | 3 | 48' | Rooftop | 3 | 6 | 3 | O | O | Steel Platform | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Jacob Walker | n/a |
| SL54XC068 | Huntsville | H266 | 6/3/13 | Lane | | | TAIC | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL54XC094 | Granite | H138 | 9/17/13 | Lane | | | Caltrop | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL54XC097 | Northridge Heights | H267 | 6/21/13 | Lane | | | TAIC | No | n/a | 6/14/13 | n/a | No SA provided at this time. | No | n/a | 6/14/13 | n/a | No MA provided at this time | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL55XC101 | Central Park West | H268 | 3/1/13 | Lane | 1/21/13 | | Smith Hyatt | Yes | n/a | 4/30/13 | Approved | n/a | Yes | n/a | 4/30/13 | Approved | n/a | No | n/a | Nick | Utah | Indoor | 225 | 135 | 135 | n/a | 3/5/13 | 3/5/13 | 3/25/13 | | Mary | | Non-Tower | | | Nick | 3 | 44' | Rooftop | 3 | 6 | 4 | I | I | Shelter w/ I-Beams | 3/25/13 | 3/25/13 | | | | Going to need to run Conduit | 200 A | N | Y | Daren Holt | n/a | | | 4/19/13 |
| SL57XC001 | Orchard Elementry | H269 | 5/4/13 | Lane | | | Smith Hyatt | Yes | 3/11/13 | 5/13/13 | Approved | n/a | Yes | 6/5/13 | 6/5/13 | Approved | MA has been corrected and approved | No | n/a | Nick | Utah | Single Outdoor | 210 | 180 | 120 | n/a | 2/6/13 | 2/6/13 | | | Mary | | | | | Nick | 3 | | Rooftop | 3 | 6 | 3 | | S/O | | | | | | | | | | | Daren Holt | n/a |
| SL60XC001 | Hale Bakery SLC068 Keebler | H270 | 5/17/13 | Lane | | | Smith Hyatt | No | n/a | 6/18/13 | n/a | No SA has been provided at this time. | No | n/a | 6/18/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL60XC017 | Spectrasite Colocation | H271 | 3/26/13 | Lane | 2/12/13 | | TAIC | Yes | n/a | 5/7/13 | Approved | n/a | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 150 | 150 | 150 | n/a | 3/27/13 | 3/27/13 | | | Mary | | Tower | | | Nick | 3 | 66' | Self Support | 3 | 6 | 5 | O | O | Steel Platform | 3/27/13 | 3/27/13 | | | | | 100 A | N | Y | Jacob Walker | n/a |
| SL60XC020 | Nextel Collocation | H139 | 6/1/13 | Lane | | | Caltrop | No | n/a | 5/14/13 | n/a | No Structural at this time | No | n/a | 5/14/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Outdoor | 150 | 150 | 150 | n/a | 2/9/13 | 2/9/13 | | | Mary | | Tower | | | Nick | 3 | | Monopole | 3 | 6 | 4 | | | | | | | | | | | | | Daren Holt | n/a |
| SL60XC028 | Saratoga | H272 | 5/2/13 | Lane | | | Fullerton | | | | | | | | | | | | No recent owner approved drawings or signed/stamped drawings in siterra | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL62XC002 | North Layton Jr. High - Site 220 | H273 | 5/27/13 | Lane | | | TAIC | No | n/a | 6/18/13 | n/a | No SA has been provided at this time. | No | n/a | 6/18/13 | n/a | No MA has been provided at this time. | No | No recent owner approved drawings or signed/stamped drawings in siterra | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL62XC012 | Jordan Landing - Site 219 | H274 | 3/9/13 | Lane | 1/22/13 | | Smith Hyatt | Yes | 6/5/13 | 6/5/13 | Approved | SA has been corrected and approved | Yes | 6/5/13 | 6/5/13 | Approved | MA has been coorected and approved | No | Everything is orrected an Approved. | Nick | Utah | Indoor | 75 | 75 | 75 | n/a | 2/10/13 | 2/10/13 | 3/26/13 | Existing equipment is indoor/site is indoor | Mary | | Non-Tower | | | Nick | 3 | 60' | Rooftop | 3 | 6 | 3 | I | I | Shelter | 3/26/13 | 3/26/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 5/7/13 |
| SL62XC022 | Howland Building - Site 218 | H275 | 6/11/13 | Lane | | | Smith Hyatt | No | n/a | 6/18/13 | n/a | No SA has been provided at this time. | No | n/a | 6/18/13 | n/a | No MA has been provided at this time. | No | n/a | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL63XC002 | Newgate Mall - Site 221 | H276 | 3/21/13 | Lane | 1/29/13 | | TAIC | No | n/a | 5/7/13 | n/a | No Structural has been ran so far. | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 90 | 90 | 90 | n/a | 2/6/13 | 2/6/13 | 3/26/13 | | Mary | | Tower | | | Nick | 3 | 58' | Monopole | 3 | 6 | 4 | O | S/O | Concrete Pad | 3/26/13 | 3/26/13 | | | | | 100 A | N | N | Jacob Walker | n/a | | | 5/24/13 |
| SL63XC006 | Boyer-Madsen Building - Site 217 | H277 | 6/3/13 | Lane | | | TAIC | No | n/a | 6/18/13 | n/a | No SA has been provided at this time. | Yes | 2/28/13 | 6/18/13 | Approved | n/a | No | n/a | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL63XC008 | 3900 South State - Site 211 | H278 | 5/25/13 | Lane | | | Smith Hyatt | Yes | 6/21/13 | 6/21/13 | Approved | n/a | Yes | 6/21/13 | 6/21/13 | Approved | n/a | No | Existing mast will fail under the conditions purposed in the drawings. The new T-Arm supports will provide adequate support for the new antennas and the existing antennas over the interim period of time. | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL63XC020 | Qwest Clearfield - Site 222 | H279 | 3/29/13 | Lane | 2/21/13 | | TAIC | | | | | | | | | | | | | Emily | Utah | Single Outdoor | 120 | 120 | 120 | n/a | 2/1/13 | 2/1/13 | 3/28/13 | no space to set MMBS Cabinet | Mary | | Tower | | | Nick | 3 | 80' | Monopole | 3 | 6 | 4 | O | S/O | Concrete Pad | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Jacob Walker | n/a |
| SL63XC022 | Riverton HS - Site 232 | H280 | 3/25/13 | Lane | 2/13/13 | | Smith Hyatt | Yes | n/a | 4/29/13 | Approved | n/a | Yes | n/a | 4/29/13 | Approved | n/a | No | n/a | Nick | Utah | Outdoor | 75 | 165 | 45 | n/a | 2/10/13 | 2/10/13 | 5/3/13 | | Mary | | Tower | | | Nick | 3 | 45' | Rooftop | 3 | 6 | 3 | O | O | Steel Platform | 5/3/13 | 5/3/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 5/15/13 |
| SL63XC026 | Boys Ranch - Site 230 | H281 | 6/15/13 | Lane | | | Fullerton | | | | | | | | | | | | CD not signed/stamped-Preliminary not for construction | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL63XC028 | Copper Hills - Site 231 | H282 | 5/12/13 | Lane | | | Smith Hyatt | Yes | 5/1/13 | 6/18/13 | Rejected | SA does not match CD, SA list 3 exisiting antennas CD lists 4 | Yes | 5/1/13 | 6/18/13 | Rejected | MA does not match CD, MA list 3 exisiting antennas CD lists 4 | | | Emily | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL63XC030 | Storage Plus - Site 226 | H283 | 4/28/13 | Lane | | | Smith Hyatt | Yes | 4/24/13 | 6/18/13 | Approved | The top section of the pole shall be replaced with a 3" std. pipe or better if the existing is less than the size | Yes | 4/24/13 | 6/18/13 | Approved | n/a | No | n/a | Emily | | | | | | | | | | | | | | | | Nick | 3 | | Monopole | 3 | 6 | 3 | | S/O | | | | | | | | | | | Daren Holt | n/a |
| SL63XC032 | Classic Trends - Site 227 | H284 | 6/15/13 | Lane | | | Fullerton | Yes | 3/1/13 | 6/17/13 | Yes | assumed. | No | n/a | n/a | n/a | n/a | n/a | wrong CDs uploaded in 315.2 | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL63XC034 | Cottonwood Theaters - Site 225 | H285 | 4/28/13 | Lane | | | Smith Hyatt | Yes | 3/6/13 | 6/17/13 | Yes | | Yes | 3/6/13 | 6/17/13 | Yes | n/a | No | n/a | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | Chris E. | | | 5/12/13 |
| SL63XC036 | I-215 Mini Storage - Site 228 | H286 | 4/30/13 | Lane | | | Smith Hyatt | No | n/a | 6/17/13 | n/a | | No | n/a | 6/17/13 | n/a | n/a | n/a | | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL63XC038 | Layton Water Tanks - Site 223 | H287 | 4/26/13 | Lane | | | TAIC | No | n/a | 5/29/13 | n/a | No Structural Analysis at this time | Yes | 4/18/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Outdoor | 120 | 150 | 120 | n/a | 2/9/13 | 2/9/13 | | | Mary | | Tower | | | Nick | 3 | 36'/36'/40' | Water Tank | 3 | 6 | 4 | O | S/O | Concrete Pad | | | | | | Need to paint antennas, RRUs, Hybrid Cables & mounts, also will need to run 3 new conduits from the Equipment to the tower where they go up. Welding will need to be done on the side of the tank for the new mounts and coax brackets. | 200 A | N | N | Jacob Walker | n/a | | | | | Need to paint antennas, RRUs, Hybrid Cables & mounts, also will need to run 3 new conduits from the Equipment to the tower where they go up. Welding will need to be done on the side of the tank for the new mounts and coax brackets. |
| SL63XC135 | Qwest Main Building - Site 224 | H288 | 5/19/13 | Lane | | | Smith Hyatt | No | n/a | 6/17/13 | n/a | | No | n/a | 6/17/13 | n/a | n/a | n/a | | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL63XC164 | Jordan Commons - Site 229 | H289 | 6/27/13 | Lane | | | Smith Hyatt | Yes | 4/12/13 | 6/17/13 | Yes | | Yes | 4/12/13 | 6/17/13 | Yes | | No | | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL70XC003 | RC Riley - T-Moblie Bennion Conservancy Collocate | H290 | 4/30/13 | Lane | | | Smith Hyatt | Yes | 3/14/13 | 6/17/13 | Yes | | No | n/a | 6/17/13 | n/a | n/a | n/a | | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL70XC004 | North Star Coatings - Site 234 | H291 | 6/25/13 | Lane | | | Fullerton | No | n/a | 6/17/13 | n/a | | No | n/a | 6/17/13 | n/a | n/a | n/a | wrong CDs uploaded in 315.2 | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL70XC007 | RC Riley (foothill UT0095) | H292 | 4/13/13 | Lane | | | Smith Hyatt | Yes | n/a | 5/8/13 | Approved | Need to add 14 more 30 lbs blocks to the Beta sector - remove dead iDEN antennas to make room for NV antennas, Standoff not run or needed | Yes | n/a | 5/8/13 | Approved | Need to add 14 more 30 lbs blocks to the Beta sector - remove dead iDEN antennas to make room for NV antennas, Standoff not run or needed | No | n/a | Nick | Utah | Indoor | 150 | 300 | 300 | n/a | 2/8/13 | 2/8/13 | | | Mary | | Non-Tower | | | Nick | 3 | 40' | Rooftop | 3 | 6 | 3 | I | I | Shelter | 5/9/13 | 5/9/13 | | | | | 200 A | N | N | Jacob Walker | Shane M. | | | 5/14/13 |
| SL72XC002 | West Mountain | H293 | 3/12/13 | Lane | 2/1/13 | | Smith Hyatt | Yes | 6/5/13 | 6/5/13 | Approved | SA was ran and we are to do a antenna swap out and mount the RRUs below the antennas. | Yes | 6/5/13 | 6/5/13 | Approved | MA was corrected and it was stated that the tower could not withhold the weight, so we are doing an antenna swap and mounting the RRUs below the antennas. | No | SA & MA were corrected. | Nick | Utah | Indoor | 120 | 120 | 120 | n/a | 2/6/13 | 2/6/13 | 3/25/13 | | Mary | | Tower | | | Nick | 3 | 70' | Guyed | 3 | 6 | 4 | I | I | Shelter | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL72XC049 | UT0049-Phase 1 B - Eagle Mountain | H294 | 4/20/13 | Lane | 2/21/13 | | Smith Hyatt | Yes | 1/21/13 | 5/29/13 | Approved | n/a | Yes | 3/15/13 | 5/29/13 | Approved | n/a | No | n/a | Nick | Utah | Single Indoor | 210 | 210 | 210 | n/a | 2/6/13 | 2/6/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 150' | Monopole | 3 | 6 | 3 | I | S/I | Shelter | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden |
| SL72XC069 | UT0069 - Phase 1A - Morgan | H296 | 5/1/13 | Lane | | | TAIC | No | n/a | 6/17/13 | n/a | | No | n/a | 6/17/13 | n/a | n/a | n/a | | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL72XC101 | UT0101 - Phase 1A | H299 | 4/8/13 | Lane | | | Smith Hyatt | Yes | 6/5/13 | 6/6/13 | Approved | SA was coorected and Approved | Yes | 6/5/13 | 6/6/13 | Approved | MA was corrected and approved | No | n/a | Nick | Utah | Indoor | 195H | 195H | 195H | n/a | 2/4/13 | 2/4/13 | 5/2/13 | | Mary | | Tower | | | Nick | 3 | 157' | Self Support | 6 | 9 | 6 | I | I | Shelter | 5/2/13 | 5/2/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden |
| SL72XC102 | Roosevelt | H300 | 2/27/13 | Lane | 1/4/13 | | Smith Hyatt | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/17/13 | Approved | Received letter verifing RAD Center | Yes | Receieved Letter - Uploaded to Siterra | Nick | Utah | Indoor | 195 | 195 | 195 | n/a | 2/6/13 | 2/6/13 | | Will have to be a temporary install, no room until decomm. | Mary | | Tower | | | Nick | 3 | 110' | Monopole | 3 | 6 | 3 | I | I | Shelter | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 4/24/13 |
| SL72XC103 | UT0103 - Phase1 A - Duchesne | H301 | 3/23/13 | Lane | 2/25/13 | | Smith Hyatt | Yes | 1/25/13 | 5/1/13 | Approved | n/a | Yes | 6/5/13 | 6/6/13 | Approved | MA was corrected and approved | No | MA was corrected. | Nick | Utah | Indoor | 150 | 150 | 150 | n/a | 2/6/13 | 2/6/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 100' | Monopole | 3 | 6 | 3 | I | I | Shelter | 3/27/13 | 3/27/13 | | | | | 200 A | N | N | Daren Holt | Chris E. | | | 4/23/13 |
| SL72XC105 | UT0105 - Phase 1A | H302 | 6/6/13 | Lane | | | Fullerton | No | n/a | 6/17/13 | n/a | | No | n/a | 6/17/13 | n/a | n/a | n/a | wrong CDs uploaded in 315.2 | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL72XC106 | UT0106 - Phase 1A | H303 | 5/24/13 | Lane | | | Fullerton | No | n/a | 6/17/13 | n/a | | No | n/a | 6/17/13 | n/a | n/a | n/a | wrong CDs uploaded in 315.2 | Craig | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL72XC113 | UT0113 - Phase 1A - Loafer - Mtn | H304 | 5/25/13 | Lane | | | Smith Hyatt | | | | | | | | | | | | | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jerry Tweden | Jerry Tweden |
| SL72XC117 | UT0117 - Phase 1A - Bear Lake | H306 | 4/26/13 | Lane | | | Caltrop | 6/10/13 | 01/29/13 | 06/18/13 | Failed | Structure fails at interim (197.4%) AND at Final (179.9%). Engineer recommends 1) If the load differs from that described in Tables 1 and 2 of this report, “Appendix B – Base Level
Drawing” or the provisions of this analysis are found to be invalid, another structural analysis should be performed. 2) The tower does not have sufficient capacity to carry the existing, reserved, and proposed loads. Modifications will be required to bring the tower into compliance with the ANSI/TIA-222-G standard for the existing, reserved, and proposed loading. The following components require
modifications: a) Tower legs from 0’ to 140’ b) Tower diagonals from 0’ to 80’, 100’ to 120’ c) Tower diagonal bolts from 120’ to 160’ d) Anchor rods e) Foundation Further engineering and detailing is required to design the necessary modifications.
3) A Professional Engineer licensed in the state of Utah shall issue design drawings for the above
modifications. This analysis report is not a construction document. | No | n/a | 06/18/13 | n/a | No MA provided at this time | No | n/a | Dez | Utah | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL72XC122 | UT0122 - Phase 1A - Price | H307 | 4/6/13 | Lane | 2/25/13 | | Smith Hyatt | Yes | 3/26/13 | 6/18/13 | Approved | Need three standoff arms. | Yes | 3/26/13 | 6/18/13 | Approved | Letter only received, nothing to verify what was measured. | No | N/A | Dez | Utah | Indoor | 75 | 75 | 75 | n/a | 2/4/13 | 2/4/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 28' | Guyed | 3 | 6 | 3 | I | I | Shelter | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL72XC123 | UT0123 - Phase 1A - Helper | H308 | 7/4/13 | Lane | | | Smith Hyatt | No | n/a | 6/18/13 | n/a | No SA provided at this time. | No | n/a | 6/18/13 | n/a | No MA provided at this time | No | N/A | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL72XC127 | Horn Mountain | H312 | 3/4/13 | Lane | 2/1/13 | | Smith Hyatt | Yes | 6/11/13 | 6/11/13 | Approved | SA was corrected and approved | Yes | 6/11/13 | 6/11/13 | Approved | MA was corrrected and approved | No | CD needs to be corrected for the mount we are installing. | Nick | Utah | Indoor | 105 | 105 | n/a | n/a | 2/6/13 | 2/6/13 | 3/25/13 | | Mary | | Tower | | | Nick | 2 | 35' | Self Support | 2 | 4 | 2 | I | I | Shelter | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 5/31/13 |
| SL72XC128 | Four Mile Hill | H313 | 2/28/13 | Lane | 2/8/13 | | Smith Hyatt | Yes | 6/6/13 | 6/6/13 | Approved | n/a | Yes | 6/6/13 | 6/6/13 | Approved | MA has been corrected and approved | No | Everything is matching | Nick | Utah | Indoor | 165 | 165 | 165 | n/a | 2/6/13 | 2/6/13 | 3/25/13 | | Mary | | Tower | | | Nick | 3 | 115' | Self Support | 3 | 6 | 3 | I | I | Shelter | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Jerry Tweden | Jerry Tweden | | | 5/31/13 |
| SL72XC138 | UT0138 - Phase 1A - Kamas | H316 | 5/5/13 | Lane | | n/a | Caltrop | Yes | 1/18/13 | 6/18/13 | N/A | No owner approved drawings to compare to. | No | N/A | 6/18/13 | N/A | No MA provided at this time | N/A | No owner approved CD uploaded to Siterra | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL72XC143 | Moab | H319 | 2/28/13 | Lane | 1/15/13 | | Smith Hyatt | Yes | 6/6/13 | 6/6/13 | Rejected | No calculations were provided in the SA. | Yes | 6/6/13 | 6/7/13 | Approved | MA corrected and approved | No | n/a | Nick | Utah | Indoor | 120 | 120 | n/a | n/a | 2/4/13 | 2/4/13 | 3/25/13 | | Mary | | Tower | | | Nick | 2 | 73' | Monopole | 2 | 4 | 2 | I | I | Shelter | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 4/23/13 |
| SL72XC255 | UT0255 - Phase 1A - Powder Mountain | H321 | 9/4/13 | Lane | | n/a | TAIC | No | n/a | 6/18/13 | n/a | No SA provided at this time. | No | n/a | 6/18/13 | n/a | No MA provided at this time | N/A | No owner approved CD uploaded to Siterra | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL72XC413 | UT0413 - Phase 1B (Devils Slide) | H325 | 6/12/13 | Lane | | n/a | TAIC | No | n/a | 6/18/13 | n/a | No SA provided at this time. | No | n/a | 6/18/13 | n/a | No MA provided at this time | N/A | No owner approved CD uploaded to Siterra | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Jacob Walker | n/a |
| SL72XC703 | ID034P- Phase 1B - Melba | G110 | 3/31/13 | Lane | 2/12/13 | | TAIC | Yes | n/a | 5/7/13 | Rejected | Structural is ran for the wrong type of mount. Ran for a Side Arm Mount, not a Sector Frame | Yes | n/a | 5/7/13 | Approved | n/a | No | n/a | Nick | Idaho | Single Indoor | 300 | 300 | 300 | n/a | 1/15/13 | 1/15/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 258' | Self Support | 3 | 6 | 3 | ID | S/I | Shelter | 3/27/13 | 3/27/13 | | | | | 200 A | N | N | Jacob Walker | Shane M. |
| SL72XC737 | ID211P - Phase 1B - McCall | G112 | 4/14/13 | Lane | 2/20/13 | n/a | TAIC | Yes | 3/4/13 | 6/18/13 | N/A | No owner approved drawings to compare to. | No | N/A | 6/18/13 | N/A | No MA provided at this time | N/A | No owner approved CD uploaded to Siterra | Dez | Idaho | Indoor | 135 | 135 | 135 | n/a | 1/15/13 | 1/15/13 | 4/23/13 | | Mary | | Tower | | | Nick | 3 | 80' | Self Support | 3 | 6 | 3 | ID | I | Shelter | 4/23/13 | 4/23/13 | | | | | 200 A | N | Y | Jacob Walker | Shane M. |
| SL73XC004 | UT0004 - Phase 1C - Brighton HS | H330 | 7/17/13 | Lane | | | Smith Hyatt | Yes | 6/6/13 | 6/6/13 | Approved | Ran for installing NV antennas on cantilever mounts | Yes | 6/6/13 | 6/6/13 | Approved | MA was corrected | No | CD needs to show the iDEN antennas that are installed beside the CDMA and NV antennas. | Nick | Utah | Single Indoor | 240 | 60 | 165 | n/a | 5/8/13 | 5/8/13 | 5/9/13 | | Mary | | Tower | | | Nick | 3 | 42'/9'/35' | Rooftop | 3 | 6 | 4 | I | S/I | Shelter | 5/9/13 | 5/9/13 | | | | | 200 A | N | N | Daren Holt | Steve Mann |
| SL73XC011 | North Orem | H331 | 3/8/13 | Lane | 1/18/13 | | Smith Hyatt | Yes | 2/21/13 | 5/14/13 | Approved | n/a | Yes | 2/19/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Utah | Single Indoor | 135 | 135 | 135 | n/a | 2/6/13 | 2/6/13 | 3/25/13 | | Mary | | Tower | | | Nick | 3 | 110' | Monopole | 3 | 6 | 5 | I | S/I | Shelter | 3/25/13 | 3/25/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 5/7/13 |
| SL73XC052 | UT0052 - Phase 1C - Dimple Dell | H332 | 7/20/13 | Lane | | n/a | Smith Hyatt | No | n/a | 6/18/13 | n/a | No SA provided at this time. | No | n/a | 6/18/13 | n/a | No MA provided at this time | N/A | No owner approved CD uploaded to Siterra | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL73XC085 | UT0085 - Phase 1C - South Salt Lake | H333 | 3/26/13 | Lane | 2/20/13 | | Smith Hyatt | Yes | 1/16/13 | 5/14/13 | Approved | n/a | Yes | 2/27/13 | 5/14/13 | Approved | n/a | No | n/a | Nick | Utah | Single Indoor | 165 | 165 | 165 | n/a | 2/6/13 | 2/6/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 120' | Monopole | 3 | 6 | 4 | I | S/I | Shelter | 3/27/13 | 3/27/13 | | | | | 200 A | N | Y | Jerry Tweden | Jerry Tweden | | | 5/24/13 |
| SL73XC114 | UT0114 - Phase 1C - South Jordan | H334 | 4/29/13 | Lane | | | Smith Hyatt | Yes | 3/28/13 | 6/14/13 | Approved | n/a | Yes | 6/19/13 | 6/21/13 | Approved | MA suggests adding bracing to prevent rotation of the horizontal pipe mounts | No | n/a | Nick | Utah | | | | | | | | | | Mary | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL73XC173 | UT0173 - Phase 1C - Bell Canyon | H335 | 5/2/13 | Lane | | | Smith Hyatt | | | | | | | | | | | | | Dez | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Daren Holt | n/a |
| SL73XC188 | UT0188 - Phase 1C - Century 16 | H336 | 4/27/13 | Lane | 2/11/13 | | Smith Hyatt | Yes | n/a | 4/29/13 | Approved | n/a | Yes | n/a | 4/29/13 | Approved | n/a | No | n/a | Nick | Utah | Indoor | 135 | 135 | 135 | n/a | 2/6/13 | 2/6/13 | 5/3/13 | | Mary | | Tower | | | Nick | 3 | 55' | Monopole | 3 | 6 | 5 | I | I | Shelter | 5/3/13 | 5/3/13 | | | | Remove 3 of the dead antennas on iDEN and there lines. | 200 A | N | N | Daren Holt | n/a | | | 5/12/13 | | Remove 3 of the dead antennas on iDEN and there lines. |
| SL73XC198 | UT0198 - Phase 1C - SLCC | H337 | 3/27/13 | Lane | 1/11/13 | | Fullerton | Yes | 1/17/13 | 5/14/13 | Rejected | Cd shows 12' T-Arms to be installed and the Structural was ran for the new equipment to go on the existing mount. They are flushed mounted to the tower. | No | n/a | 5/14/13 | n/a | No MA provided at this time | No | n/a | Nick | Utah | Indoor | 105 | 105 | 105 | n/a | 1/2/13 | 1/2/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 5 | I | I | Shelter | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Daren Holt | n/a |
| SL73XC304 | UT0304 - Phase 1C - Jordan Commans | H338 | 4/2/13 | Lane | 3/1/13 | | Smith Hyatt | Yes | 6/6/13 | 6/6/13 | Approved | n/a | Yes | 6/6/13 | 6/6/13 | Approved | MA has been corrected and approved | No | n/a | Nick | Utah | Indoor | 165 | 165 | 135 | n/a | 2/9/13 | 2/9/13 | | | Mary | | Tower | | | Nick | 3 | 35'/45' | Rooftop | 3 | 6 | 5 | I | I | Shelter | | | | | | | | | | Daren Holt | Steve Mann | | | 4/19/13 |
| SL73XC341 | UT0341 - Phase 1C - Franklin Covey Stadium | H339 | 3/23/13 | Lane | 3/2/13 | | Smith Hyatt | Yes | n/a | 4/29/13 | Rejected | CD doesn’t match Structural ran on tower or mount. Structural ran at 50’ of the monopole and not 56’ on the 3” pipe sticking off the top of the Monopole. Nothing is captured in the Structural for adding a mount for the RRUs on the monopole | Yes | n/a | 4/29/13 | Rejected | CD doesn’t match Structural ran on tower or mount. Structural ran at 50’ of the monopole and not 56’ on the 3” pipe sticking off the top of the Monopole. Nothing is captured in the Structural for adding a mount for the RRUs on the monopole | No | Structural for Mount and Tower need to be redone. | Nick | Utah | Indoor | 90 | 90 | 90 | n/a | 1/31/13 | 1/31/13 | 3/27/13 | | Mary | | Tower | | | Nick | 3 | 56' | Monopole | 3 | 6 | 3 | I | I | Shelter | 5/9/13 | 5/9/13 | | | | On Hold until we get proper Structurals and mount analysis | 200 A | N | N | Jacob Walker | n/a | | | 4/29/13 |
| SL73XC364 | UT0364 - Phase 1C - North Salt Lake | H340 | 3/31/13 | Lane | 2/15/13 | | Fullerton | Yes | 1/16/13 | 5/10/13 | Approved | n/a | Yes | 2/6/13 | 5/10/13 | Approved | n/a | No | n/a | Nick | Utah | Indoor | 105 | 105 | 105 | n/a | 1/2/13 | 1/2/13 | 3/28/13 | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 4 | I | I | Shelter | 3/28/13 | 3/28/13 | | | | | 200 A | N | N | Daren Holt | Clay Schutzer | | | 5/28/13 |
| SL73XC373 | UT0373 - Phase 1C - Interstate 15 & 1700 S | H341 | 4/13/13 | Lane | 2/11/13 | | Smith Hyatt | Yes | 1/16/13 | 5/14/13 | Approved | n/a | Yes | 4/4/13 | 6/6/13 | Approved | MA is corrected & approved. | No | MA is coorected. | Nick | Utah | Indoor | 105 | 105 | 105 | n/a | 1/31/13 | 1/31/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 60' | Monopole | 3 | 6 | 5 | I | I | Shelter | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 5/15/13 |
| SL73XC381 | UT0381 - Phase 1C - 33rd & Interstate 15 | H342 | 4/14/13 | Lane | 2/11/13 | | Smith Hyatt | Yes | n/a | 5/1/13 | Approved | n/a | Yes | n/a | 5/1/13 | Approved | n/a | No | CD showing pulling CDMA and iDEN off at Iterim and it is not needed . Please correct for construction | Nick | Utah | Indoor | 105 | 105 | 105 | n/a | 1/31/13 | 1/31/13 | 3/29/13 | | Mary | | Tower | | | Nick | 3 | 57' | Monopole | 3 | 6 | 4 | I | I | Shelter | 3/29/13 | 3/29/13 | | | | | 200 A | N | N | Daren Holt | n/a | | | 5/13/13 |
| SL97XC002 | BYU Rexburg | G114 | n/a | Lane | | | TAIC | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL97XC003 | BYU Rexburg BTS #2 | G115 | n/a | Lane | | | TAIC | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL97XC004 | CNSUT00055 Movie Set | H343 | n/a | Lane | | | Smith Hyatt | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL97XC005 | SL97XC005 BTS #2 (CNS DPT ENRGY) | G116 | n/a | Lane | | | TAIC | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL98XC004 | | | n/a | Lane | | | Smith Hyatt | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL98XC007 | LDS Headquarters - BTS | H345 | n/a | Lane | | | Smith Hyatt | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |
| SL98XC008 | CNSUT00058 (CNS Montage) | H346 | n/a | Lane | | | Smith Hyatt | | | | | | | | | | | | | n/a | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | n/a | n/a |