| RISK ASSESSMENT (BEFORE CONTROLS) |
| Task or Condition | LO | FE | DPH | NP | HRN | Risk Level (Before) |
| Condition #1 - Side acess panel opens with a knob versus a locking device | 5 | 2.5 | 6 | 1 | 75 | Medium |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| RISK ASSESSMENT (AFTER CONTROLS) |
| Task | LO | FE | DPH | NP | HRN | Risk Level (Before) |
| Condition #1 - After installing a locking device on the side access panel. | 1 | 2.5 | 6 | 1 | 15 | Low |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Negligible |
| Risk Levels: |
| >500 | Extremely High |
| >250 and <500 | High |
| >50 and <250 | Medium |
| >5 and <50 | Low |
| Less than or equal to 5 | Negligble |