USW1.575.202130 - NURS-6512C-1/NURS-6512D-1/NURS-6512N-1-Advanced Health Assessment2020 Winter Qtr 11/30-02/21-PT27
SafeAssign Drafts
Monica Castelao
on Sun, Dec 20 2020, 10:27 PM
38% highest match
Submission ID: 2e645ef3-96b8-496f-9e92-71ac86ae66e4
Citations (8/8)
-
1
Another student's paper
Citation is highlighted. Click to remove highlighting
-
2
https://www.cd-diatest.com/cdia-sup-tm-sup-strep-a-antigen-test-kit_p342.html
Citation is highlighted. Click to remove highlighting
-
3
http://www.spanbiotech.com/sale-8882157-one-step-strep-ag-rapid-test-uncut-sheets.html
Citation is highlighted. Click to remove highlighting
-
4
http://hmamedicalclinic.com/d/documents.andatech.com.au1.html
Citation is highlighted. Click to remove highlighting
-
5
Another student's paper
Citation is highlighted. Click to remove highlighting
-
6
Another student's paper
Citation is highlighted. Click to remove highlighting
-
7
Another student's paper
Citation is highlighted. Click to remove highlighting
-
8
https://blackstone.edu/medical-office-assistant/
Citation is highlighted. Click to remove highlighting
1
Case Study
Monica Castelao
Walden University
1
Case Study Group A Streptococcus is one of the most significant causes of acute upper respiratory tract infections.
Suspected Entry: 75% match
Uploaded - Week3CastelaoM.extention.docx
Case Study Group A Streptococcus is one of the most significant causes of acute upper respiratory tract infections
Source - Another student's paper
Influenza is one of the most significant causes of acute upper respiratory tract infections nationwide
Its early diagnosis and treatment has been found to reduce the se4verity of symptoms and further complications such as rheumatic fever and glomerulonephritis. Moreover, the conventional detection processes for detecting the microorganisms from throat swabs often entail isolation and subsequent detection of viable pathogens by strategies that are not time-consuming (Barakat et al., 2019). The rapid Strep A test provides results within a few minutes.
How the Assessment tool is used Purpose The purpose of the assessment tool is to detect Strep A carbohydrate antigen in a throat swab. Therefore, it is an assessment tool that is qualitative in nature, and is employed by performing lateral flow immunoassay for the detection of Strep A.
2
in such a test, the antibody that is unique to Strep A carbohydrate antigen is coated on the test line region of the test (Finkelstein et al., 2017).
Suspected Entry: 75% match
Uploaded - Week3CastelaoM.extention.docx
in such a test, the antibody that is unique to Strep A carbohydrate antigen is coated on the test line region of the test (Finkelstein et al., 2017)
Source -
https://www.cd-diatest.com/cdia-sup-tm-sup-strep-a-antigen-test-kit_p342.html
In this test, antibody specific to Strep A carbohydrate antigen is coated on the test line region of the test
3
As soon as the test is immersed into a specimen, the extracted throat swab specimen reacts with the antibody to strep A, which is coated onto particles (Barakat et al., 2019).
Suspected Entry: 79% match
Uploaded - Week3CastelaoM.extention.docx
As soon as the test is immersed into a specimen, the extracted throat swab specimen reacts with the antibody to strep A, which is coated onto particles (Barakat et al., 2019)
Source -
http://www.spanbiotech.com/sale-8882157-one-step-strep-ag-rapid-test-uncut-sheets.html
After the test strip is immersed into a specimen, the extracted throat swab specimen reacts with an antibody to Strep A that is coated onto particles
The resultant mixture moves up the membrane to react with the antibody to Strep A on the membrane and produce a colored line in the test line area.
Suspected Entry: 79% match
Uploaded - Week3CastelaoM.extention.docx
The resultant mixture moves up the membrane to react with the antibody to Strep A on the membrane and produce a colored line in the test line area
Source -
http://www.spanbiotech.com/sale-8882157-one-step-strep-ag-rapid-test-uncut-sheets.html
This mixture migrates up the membrane to react with the antibody to Strep A on the membrane and generate a colored line in the test line region
How it is conducted The process of carrying out a rapid Strep A test begins by gathering all the necessary supplies and equipment. All the reagents are then brought to room temperature and the expiration date is checked. The manufacturer’s directions for the reagent’s temperature should be strictly followed. Any supply that is outdated should never be utilized (Cunha, 2017). The health professional should put on a fluid impermeable laboratory coat before commencing the testing process. Moreover, it is important to put on personal protective equipment when carrying out the testing exercise. Before undertaking the first patient test from a new test kit, a positive and negative control test should be undertaken with the utilization of the control swabs that are found in the kit. Additionally, it is important to confirm that both controls responded correctly, after which the control results are recorded on the log sheet (Niedzwieck et al., 2019). Both the control swabs should be checked before patients are examined. In the event that the controls indicate the appropriate results, then the test kit is deemed reliable.
After interacting with the patient and knowing their details, it is important to explain to them the procedure in a way that they can understand. Any general questions should be answered about the collection processes before the detailed instructions are provided. Any general questions that the patient may ask about the collection procedures should be answered prior to giving the detailed instructions (Niedzwieck et al., 2019). Moreover, it is important to identify the patient’s situation using two different methods in order to ensure that the information gathered re accurate. Gloves and face protecting should be put on, after which a throat specimen should be collected using a rayon swab that is provided in the test kit. The 5test cassette is removed from the foil pouch, and placed on a clean, dry, level surface. Using the notch that is at the back of the chamber as a guide, it I important to insert the patient’s swab completely into the swab chamber. The extraction bottle is then placed between the thumb and the forefinger, and squeezed once to break the glass ampule that is within the extraction solution bottle. Moreover, the bottle should be vigorously shaken five times to mix the solutions. The solution should turn green. The change in color is supposed to be an indication of extraction reagent integrity and that the extraction procedure was undertaken correctly (Niedzwieck et al., 2019). It is important to immediately remove the cap on the extraction solution bottle and hold the bottle vertically over the chamber to speedily fill the chamber to the rim. The liquid extract reacts with the swab and then flows into the test cassette, passing through the test area, to the internal control region. The shield is then removed and the test results waited for five minutes. A positive results manifests by a pink line showing the Y area. This indicates the presence of Streptococcus pygenes antigens. A negative result, on the other hand is there when there is no pink line that appears in the T test area.
2
Information that is gathered Information is gathered by assessing the mixture that migrates up the membrane to react with the antibody to Strep A on the membrane.
Suspected Entry: 64% match
Uploaded - Week3CastelaoM.extention.docx
Information that is gathered Information is gathered by assessing the mixture that migrates up the membrane to react with the antibody to Strep A on the membrane
Source -
https://www.cd-diatest.com/cdia-sup-tm-sup-strep-a-antigen-test-kit_p342.html
The mixture migrates up the membrane to react with the antibody to Strep A on the membrane and generate a color line in the test line region
If it generates a colored line in the test line area, then the presence of such a colored line suggests a positive result. Its absence, on the other hand, indicates a negative result. This information, therefore, can be employed to perform diagnosis and testing of the presence of Streptococcus bacteria (Cohen et al., 2016). To act as an ‘aprocedural’ control, the colored line often appear at the controlling region.
4
This indicates that proper volume of the specimen has been included and the membrane wicking has taken place.
Suspected Entry: 62% match
Uploaded - Week3CastelaoM.extention.docx
This indicates that proper volume of the specimen has been included and the membrane wicking has taken place
Source -
http://hmamedicalclinic.com/d/documents.andatech.com.au1.html
No line appears in the test region that proper volume of specimen has been added and membrane wicking has occurred
Usually, the test has Strep A antibody coated particles and Strep A antibody coated on the membrane. For precautionary reasons, it is meant for professional in vitro diagnostic utilization only. As such, it is never utilized after its expiry date.
Evaluation of the Validity and Reliability of the Assessment Tool He diagnostic and assessment tool is highly valid and reliable. The test, for instance, is 95 percent effective across different populations and groups. Moreover, it provides important information for the antibiotic decision making for patients presenting with acute pharyngitis. More importantly, it has a short waiting time for detecting the results of the diagnosis and testing processes.
References
Barakat, A.
5
J., Evans, C., Gill, M., & Nelson, D.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
J., Evans, C., Gill, M., & Nelson, D
Source - Another student's paper
J., Evans, C., Gill, M., & Nelson, D
(2019).
5
Rapid strep testing in children with recently treated streptococcal pharyngitis.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
Rapid strep testing in children with recently treated streptococcal pharyngitis
Source - Another student's paper
Rapid strep testing in children with recently treated streptococcal pharyngitis
Pediatric Investigation, 3(1), 27-30.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
Pediatric Investigation, 3(1), 27-30
Source - Another student's paper
Pediatric Investigation, 3(1), 27-30
Cohen, J.
5
F., Bertille, N., Cohen, R., & Chalumeau, M.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
F., Bertille, N., Cohen, R., & Chalumeau, M
Source - Another student's paper
F., Bertille, N., Cohen, R., & Chalumeau, M
(2016).
5
Rapid antigen detection test for group A streptococcus in children with pharyngitis.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
Rapid antigen detection test for group A streptococcus in children with pharyngitis
Source - Another student's paper
Rapid antigen detection test for group A streptococcus in children with pharyngitis
6
Cochrane Database of Systematic Reviews, (7).
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
Cochrane Database of Systematic Reviews, (7)
Source - Another student's paper
Cochrane Database of Systematic Reviews, (7)
Cunha, B. A. (2017).
5
A positive rapid strep test in a young adult with acute pharyngitis:
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
A positive rapid strep test in a young adult with acute pharyngitis
Source - Another student's paper
A positive rapid strep test in a young adult with acute pharyngitis
be careful what you wish for!
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
be careful what you wish for
Source - Another student's paper
Be careful what you wish for
7
IDCases, 10, 58-59.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
IDCases, 10, 58-59
Source - Another student's paper
IDCases, 10, 58-59
Finkelstein, S.
7
N., Horowitz, G.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
N., Horowitz, G
Source - Another student's paper
N., Horowitz, G
L., Diamond, D.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
L., Diamond, D
Source - Another student's paper
L., Diamond, D
V., Bartels, P., Joseph, J., Hartman, L.,.
Suspected Entry: 99% match
Uploaded - Week3CastelaoM.extention.docx
V., Bartels, P., Joseph, J., Hartman, L.,
Source - Another student's paper
V., Bartels, P., Joseph, J., Hartman, L.,
& Slack, W. V. (2017).
7
Rapid Streptococcal Antigen Detection Test Performed by Parents of Children with Sore Throat.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
Rapid Streptococcal Antigen Detection Test Performed by Parents of Children with Sore Throat
Source - Another student's paper
Rapid Streptococcal Antigen Detection Test Performed by Parents of Children with Sore Throat
Journal of Participatory Medicine, 9.
Suspected Entry: 100% match
Uploaded - Week3CastelaoM.extention.docx
Journal of Participatory Medicine, 9
Source - Another student's paper
Journal of Participatory Medicine, 9
Niedzwiecki, B., Pepper, J., & Weaver, P. A. (2019).
8
Kinn's The Administrative Medical Assistant E-Book:
Suspected Entry: 66% match
Uploaded - Week3CastelaoM.extention.docx
Kinn's The Administrative Medical Assistant E-Book
Source -
https://blackstone.edu/medical-office-assistant/
Kinn’s The Administrative Medical Assistant, by Alexandra P
An Applied Learning Approach. Elsevier Health Sciences.