PNEUMATIC AND HYDRAULIC EQUIPMENT
MODULE TITLE : APPLICATIONS OF PNEUMATICS AND
HYDRAULICS
TOPIC TITLE : PNEUMATIC AND HYDRAULIC EQUIPMENT
LESSON 3 : ANCILLARY EQUIPMENT
APH - 2 - 3
© Teesside University 2011
Published by Teesside University Open Learning (Engineering)
School of Science & Engineering
Teesside University
Tees Valley, UK
TS1 3BA
+44 (0)1642 342740
All rights reserved. No part of this publication may be reproduced, stored in a
retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise without the prior permission
of the Copyright owner.
This book is sold subject to the condition that it shall not, by way of trade or
otherwise, be lent, re-sold, hired out or otherwise circulated without the publisher's
prior consent in any form of binding or cover other than that in which it is
published and without a similar condition including this
condition being imposed on the subsequent purchaser.
________________________________________________________________________________________
INTRODUCTION ________________________________________________________________________________________
In the previous lesson we dealt with types of compressor and their control. In
this lesson we continue with the compressor installation and the ancillary
equipment required to ensure that the compressed air produced is of an
acceptable quality.
________________________________________________________________________________________
YOUR AIMS ________________________________________________________________________________________
On completion of this lesson you should be able to:
• explain the meaning of the term Free Air Delivered (FAD)
• estimate the amount of compressed air that a machine should deliver
for a given set of circumstances
• sketch a typical compressor plant installation in block diagram form
• calculate the amount of condensate delivered from a compressor for a
known set of circumstances
• state and describe three methods of compressed-air drying.
1
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
FREE AIR DELIVERED (FAD) ________________________________________________________________________________________
Compressors and air-tools are rated in terms of the volume flow-rate of air at
standard atmospheric conditions taken in and delivered, rather than the actual
volume of compressed air delivered, which will depend on the delivery
pressure employed. This flow rating is known as Free Air Delivered (FAD)
and is usually expressed in units of m3 min–1 or l s–1.
Local atmospheric conditions, in terms of pressure, temperature and humidity,
will vary with weather, altitude, and geographic location: e.g. at high altitude
the air pressure and temperature will be lower than at sea level. Because
compressors are used in locations where these atmospheric variations occur,
and also to deliver air at differing pressures it is important that a reference
standard is used so that compressor capacities may be properly compared.
There are two standards commonly used to define free air conditions; these
are:
• S.T.P. (standard temperature and pressure) where the values used are:
Temperature: 0°C
Pressure: 101.3 kPa or 1.013 bar.
• N.T.P. (normal temperature and pressure) where the values used are:
Temperature: 15°C
Pressure: 101.3 kPa or 1.013 bar.
FIGURE 1 illustrates the difference between free air and compressed air; the
ratio which connects the two is approximately the compression ratio of the
machine.
2
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIG. 1 Free Air and Compressed Air
With reference to FIGURE 1, we can calculate the amount of compressed air
produced if we know various values. These are:
• the pressure at the compressor inlet p1 • the volume taken in at the inlet V1 • the pressure at the compressor outlet p2.
If we presume isothermal compression for simplicity, then T1 = T2
so
therefore
We will now consider the effect of various values for p1 and p2.
p V p V
V p V
p
1 1 2 2
2 1 1
2
=
=
F.A.D.
Compressed air
Compressor
p1 V1 T1 p2 V2 T2
Atmospheric free air
3
Teesside University Open Learning (Engineering)
© Teesside University 2011
Example 1
The compressor in FIGURE 1 is rated at producing 5 m3 min–1 FAD (NTP).
Calculate the volume of compressed air produced per minute, if the
temperature at the outlet is at ambient conditions, the outlet pressure is 6 bar
absolute, and the inlet pressure is 1.013 bar abs.
Solution
Using
Therefore
Note that this is a simplification of FAD to illustrate the effect that atmospheric
pressure and system pressure have on output volume.
The compressor in FIGURE 1 has its usage changed and now produces air at a
pressure of 7.5 bar absolute. Calculate the volume of compressed air produced per
minute if all other conditions remain the same and comment on the effect of increasing
the working pressure of a system with respect to the volume of air delivered.
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
________________________________________________________________________________________
p V p V
V p V
p
V
V
1 1 2 2
2 1 1
2
2
2
1 013 5 6
0 844
=
=
=
= m mi3
.
.
×
nn–1
4
Teesside University Open Learning (Engineering)
© Teesside University 2011
It can be seen that as system pressure increases the flow-rate of compressed air reduces.
Show by calculation the effect on compressed air flow-rate if the pressure at the inlet
were to drop to 0.85 bar absolute, all other values being the same as above. Comment
on your results.
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
________________________________________________________________________________________
It can be seen that as atmospheric pressure reduces so too does the flowrate of compressed
air into the system.
p V p V
V p V
p
V
V
1 1 2 2
2 1 1
2
2
2
0 85 5 7 5
0 567
=
=
=
= m m3
. .
.
×
iin–1
p V p V
V p V
p
V
V
1 1 2 2
2 1 1
2
2
2
1 013 5 7 5
0 675
=
=
=
= m 3
. .
.
×
mmin–1
5
Teesside University Open Learning (Engineering)
© Teesside University 2011
HUMIDITY
Humidity is the degree of dampness of the air and it may be defined as "the
mass of water vapour present in a given unit volume of air".
Air is said to be saturated when it is holding the maximum amount of moisture
as vapour. The amount of moisture that a given volume of air can support is
dependent upon its temperature. As the temperature of air increases, it can
hold more moisture before saturation occurs.
FIGURE 2 shows a chart illustrating the amount of moisture saturated air can
support at 1.013 bar. To read the chart, select the temperature of the air; draw
a line vertically upwards to a point where it intersects the curve, then
horizontally along until the vertical axis is reached; then read off the water
content.
Using the chart (FIGURE 2) opposite find the amount of moisture present in saturated
air at the following temperatures:
(a) 10°C
(b) 20°C
(c) 50°C
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
________________________________________________________________________________________
6
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIG. 2 Dew-point Chart (at 1.013 bar)
– 40 –30 –20 –10 0 10 20 30 40 50 60 70 80 90 100
233 253 273 293 313 333 353 373 K
°C
W a te
r co
n te
n t
Temperature
0.1
0.2
0.3
0.4 0.5
1
2
3
5
10
20
30
40 50
100
200
500
4
g m–3
7
Teesside University Open Learning (Engineering)
© Teesside University 2011
Considering 1 m3 of air at 20°C, from the chart we found it could support
16 grams of water vapour. If that 1 m3 of air is now cooled to 10°C it can only
support 9 grams, hence there are (16 – 9) = 7 grams of water condensed out as
liquid. This is one of the basic principles that we apply for the removal of
moisture from compressed air systems – cooling the air.
We will now consider the effect of compressing 1 m3 of saturated air from
1 bar abs to 2 bar abs at a constant temperature of 20°C.
From the gas laws we know that to compress air to twice its pressure we must
halve its volume: therefore we are left with 0.5 m3 of air at 20°C. From the
chart we know that air at 20°C can support 16 g m–3. Therefore 0.5 m3 can
only support 8 grams: the other 8 grams is given up as condensate. From this
we can see that compressing saturated air via a volume reduction results in
moisture being given up. FIGURE 3 illustrates this process.
FIG. 3 Moisture Generated by Compression
A B
1 m3 saturated air at 1 bar abs
supporting 16 grams
of moisture
0.5 m3 saturated air at 2 bar abs
supporting 8 grams of moisture
8 grams of moisture given
up
(a) 9 g m
(b) 16 g m
(c) 80 g m
–3
–3
–3
8
Teesside University Open Learning (Engineering)
© Teesside University 2011
Therefore, we can see that the amount of water which can be supported by a
given volume of air, is dependent on its pressure.
FIGURE 4 shows the amount of moisture saturated air can hold for different
pressures. To read the chart, select the temperature of the air, draw a line
vertically upwards to a point where it intersects the line for the pressure being
considered, then horizontally to read off the water content.
9
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIG. 4 Pressure Dew Point Chart
0 10 20 30 40 °C
W a te
r co
n te
n t
Temperature
35
30
25
20
15
10
5
0
g m–3
1.4 bar
2 bar
2.6 bar
5 bar
3.5 bar
7 bar
10
Teesside University Open Learning (Engineering)
© Teesside University 2011
Dew Point
If we take a sample of air, which possesses moisture but is not saturated, and
then cool it to a point where saturation occurs and liquid starts to form, the
temperature at which this occurs is known as the dew point.
Saturation Quantity
This is the maximum amount of vapour by mass which a sample of air can
support.
Absolute Humidity
This is the amount of water vapour by mass which a sample of air, which is not
fully saturated, is supporting.
Relative Humidity
This is the ratio of absolute humidity compared to the saturation quantity, i.e.
A sample of air, 1 m3 at 20°C, is supporting 10 grams of moisture. Calculate the
relative humidity of the sample.
...................................................................................................................................................
...................................................................................................................................................
________________________________________________________________________________________
RH = absolute humidity saturation quantity
expressed as a percentage( )
11
Teesside University Open Learning (Engineering)
© Teesside University 2011
From the dew point chart the saturation quantity at 20°C is 16 grams and from the question
the absolute humidity is 10 grams. Therefore:
This means that the air is supporting only 62.5% of the moisture that it can
actually support before saturation occurs.
From this we can say that, if the air taken into a compressor is of a low relative
humidity, the problems associated with water in the system will be reduced.
RH = 10 16
RH =
× 100
62 5
%
. %
RH = absolute humidity saturation quantity
expressed as a percentage( )
12
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
COMPRESSOR HOUSE INSTALLATION AND ANCILLARY EQUIPMENT ________________________________________________________________________________________
The correct siting of the compressor and its ancillary equipment is very important
to its operation. If the compressor is installed in an unsuitable position, this can
adversely affect the operational performance of the compressor, with regard to
quality and quantity of air delivered into the system, as well as exposing the
compressor to the potentially harmful effects of a dusty or damp environment.
FIGURE 5 shows the arrangement of a typical compressed air plant.
Wherever possible it should be sited to operate with the greatest efficiency:
this would normally suggest that it is sited somewhere central in the plant or
factory, so as to avoid large pressure drops over long pipe runs to the more
remote parts of the plant.
Ideally the compressor should be located in its own purpose-built building
whose flooring and walls should be sealed to reduce dust entering the
compressor intake, if the air is being drawn from inside the building. If the air
is being drawn from outside the compressor house, then the building should be
sited away from steam boilers, cooling towers or other high humidity
equipment. Where possible it should also be sited on the coolest side of the
building, and away from any plant which generates large amounts of dust.
This precaution will ensure that the air being drawn into the compressor is cool
and dry and reasonably dust-free.
Failure to heed these precautions will result in reduced compressor throughput,
increased moisture content and premature blocking of intake filters.
The compressor house should also be adequately sized and well ventilated, to
allow unrestricted access for servicing and maintenance, and also to allow
unrestricted entry of ambient air to flow around the compressor to assist in its
cooling.
13
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIG. 5 Typical Compressed-air Plant
S a fe
ty va
lv e
S to
p va
lv e
W a ll
M o is
tu re
se p a ra
to r
P re
ss u re
g a u ge
s
A ft
er co
o le
r
A u to
m a ti
c d ra
in t
a p s
A ir
re ce
iv er
P re
ss u re
g a u ge
Tw o s
ta ge
d o u b le
a ct
in g
a ir
c o m
p re
ss o r
R el
ie f
va lv
e In
te rc
o o le
r
W a ll
A ir
i n ta
ke fi
lt er
M o to
r
A ir
s il
en ce
r
F o u n d a ti
o n b
lo ck
B el
t d ri
ve
14
Teesside University Open Learning (Engineering)
© Teesside University 2011
COMPRESSOR FOUNDATIONS
Foundation requirements for compressor plant will vary from machine to
machine depending upon its size, type and how it is being dr iven.
Reciprocating piston machines are notorious 'bouncers' and the bigger they are
the worse the problem seems to get. The foundation requirements for this type
of machine are often quite substantial and normally require isolation from the
structure of the building so that noise and vibration are not transmitted into the
fabric of the building or into other machines causing a detrimental effect on
their performance or reduction in their working life.
Rotary machines do not usually provide the same problems. Many machines,
including the prime mover and control equipment, come in a packaged form,
which only requires to be fastened to the floor, and isolated from generated or
transmitted vibration.
COMPRESSOR ANCILLARY EQUIPMENT
Although the compressor and its prime mover are the most important parts of a
compressed air production plant, other items of equipment are necessary to
allow the compressor to fulfil its function as efficiently and effectively as
possible.
The most commonly found ancillary units are listed below.
Air Intake Filter/Silencer
Atmospheric air, especially in industrial areas, is extremely dirty. To prevent
harmful matter from entering the internal parts of the machine, filters are fitted
to the suction or intake line. They can be either oil-bath or paper-type element
filters and, needless to say, will require to be cleaned and serviced at regular
intervals, as stipulated by the compressor supplier.
15
Teesside University Open Learning (Engineering)
© Teesside University 2011
An air silencer is sometimes necessary, to reduce the noise generated by the
rushing of air into the compressor: this can be fitted before or after the filter,
depending upon the silencing effect required. FIGURES 6 and 7 show
examples of wet and dry type filters. However, it should be noted that, for
compressors fitted with carbon rings etc., filters must always be of the dry
type.
FIG. 6 Oil Bath Filter FIG. 7 Intake Filter with Silencer
Care should be taken with the placing of air intake filters, to ensure that the air
drawn into the compressor is as cool as possible and free from any potentially
harmful fumes and vapours from factory or plant processes.
Vibration of walls and windows can also occur if the intake filter is sited in
contact with them or in close proximity to them, particularly if no attempt is
made to dampen transmitted vibrations.
16
Teesside University Open Learning (Engineering)
© Teesside University 2011
What would be the effect on the quality of air produced should the compressor intake
be sited incorrectly, i.e. in a warm and moist position?
...................................................................................................................................................
...................................................................................................................................................
________________________________________________________________________________________
The air taken into the compressor would have a high relative humidity and excessive
amounts of moisture would be carried into the system.
Intercooler
An intercooler is a heat exchanger placed between each stage of compression
to cool the air and reduce its volume, prior to it being further compressed in
the next stage. This greatly improves compressor efficiency.
The cooler will also reduce the air's moisture-carrying capacity and cause
moisture to be condensed in the intercooler. If this moisture was carried over
into the next compression stage and condensed on the cylinder walls, it would
result in damage to the compressor's internal components. The moisture
collected in the intercooler must be removed at regular intervals, to prevent
build-up and moisture being carried over. This is usually achieved using some
form of automatic drain trap, which will sense the presence of water and
actuate to remove it from the intercooler.
Intercoolers may be air-blast or water-cooled, but must be regularly serviced
and cleaned to ensure that the air-cooling mechanism is working efficiently.
FIGURE 8 shows a compressor with an intercooler fitted.
17
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIG. 8 Two-stage Compressor with Intercooler
Aftercooler
When a compressor operates, it takes in large volumes of atmospheric air,
which always contains some moisture in the form of water vapour. The
compression process reduces the volume of the air, but cannot reduce the
volume of water. For this reason, it must be noted that the compressed air
emerging from a compressor, at a temperature slightly higher than ambient
intake temperature, is always 100% saturated. This means that it is holding the
maximum amount of moisture that the sample of air can hold at that particular
temperature and pressure. Therefore any reduction in temperature or pressure
of the air will cause moisture to precipitate.
The following calculation, using the gas laws and the dew point graph shown
in FIGURE 2 and the pressure dew point graph in FIGURE 4, indicates the
amount of condensate generated during compression.
Stage 1 Stage 2
Cooling water out Cooling water in
Intercooler
18
Teesside University Open Learning (Engineering)
© Teesside University 2011
Example
A compressor is delivering 5 m3 min–1 FAD at 6 bar gauge pressure. The air is
being drawn into the compressor at an ambient temperature of 23°C. The
relative humidity of the air being drawn in is 68% and its pressure is
1.01 bar abs. Calculate the amount of condensate per hour that would drop out
at a point after the compressor, where the air has been cooled to a temperature
of 32°C.
Solution
During 1 hour at 5 m3 min–1 FAD:
Conditions at the inlet port of the compressor are:
Conditions at a point after the compressor are:
Using the gas laws:
p V
T
p V
T
V p V T
T p
1 1
1
2 2
2
2 1 1 2
1 2
=
=∴
p T2 26 1 01 7 01 32 273 305= = bar abs., = = K+ +. .
p V T1 1 11 01 300 23 273 296= bar, = m = = K 3. , +
volume delivered = = m FAD35 60 300×
19
Teesside University Open Learning (Engineering)
© Teesside University 2011
Therefore, air volume after compression:
From the dew point graph (FIGURE 2):
1 m3 of air at 23°C can hold 20 g of moisture at 100% relative humidity (RH).
At 68% RH this mass would fall to:
Therefore, moisture taken in at the compressor inlet every hour
Referring to the dew point graph (FIGURE 4) for a pressure of 7 bar (approx.
7.01), 1 m3 of air at 32°C can hold 4 g of moisture at 100% RH.
Therefore the moisture suspended by the air after compression is:
4 = g× 44 53 178.
13.6 = g× 300 4080
20 68 100
13 6 ×
= g.
V
V
2
2
1 01 300 305 296 7 01
92 415 2074 96
44 5
=
=
=
. .
.
.
× × ×
33 m 3
20
Teesside University Open Learning (Engineering)
© Teesside University 2011
Considering that in the unit time:
Then the moisture the compressed air cannot hold in one hour is:
Since 1000 g water occupies 1 litre, the air will deposit 3.9 litres of water
every hour.
The aftercooler is the device used to cool the air immediately after
compression, to encourage the air to drop as much condensate as possible,
before it reaches the air receiver.
The most efficient aftercoolers are usually water-cooled: the best are those that
can produce the lowest air temperatures. However, as a general guide, the air
leaving the compressor installation, prior to being used, should be no more
than 15 degrees above the air intake temperature.
FIGURE 9 shows an illustration of a water-cooled aftercooler with an integral
moisture separator. Note particularly the safety valve, which protects the shell
of the heat exchanger from excessive pressure build-up, and also the automatic
drain trap which is used to periodically remove the precipitated moisture from
the bottom of the cooler.
4080 = g– 178 3902
condensate drop out = moisture taken
21
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIG. 9 Water Cooled Aftercooler
In situations where cooling water is not available or is too expensive an option
to use, then the air-blast aftercooler becomes the only viable alternative.
In this device ambient air is blown by an electric motor and fan over a bank of
fins through which the compressed air flows. It does not usually provide the
same degree of cooling as a water-cooled heat exchanger. The compressed air
discharge temperature is likely to be about 6 degrees higher than for a
Safety valve
Incoming hot compressed air
Outgoing cooling water
Throttle valve
Water separator Automatic condensate
draining
Outgoing compressed air
Thermometer for outgoing compressed air
Incoming cooling water
Cooling element
Cooler body
22
Teesside University Open Learning (Engineering)
© Teesside University 2011
watercooled device. However, it will still precipitate moisture from the air,
and needs to be fitted with a valve to allow for the automatic removal of this
moisture from the unit.
In both types of aftercooler it is of prime importance that all heat exchanger
surfaces be kept as clean as possible for the unit to function at its maximum
efficiency.
FIGURE 10 shows an illustration of an air-blast aftercooler with an automatic
drain trap fitted.
FIG. 10 Air Blast Aftercooler
Strainer
CA air trap
Air
23
Teesside University Open Learning (Engineering)
© Teesside University 2011
MOISTURE SEPARATOR
After the air has been cooled in the aftercooler and water has been condensed,
it is necessary to separate the water droplets from the air supply, to prevent
them from being carried over into the system. Since the water droplets are a
lot heavier than the air, many separator types rely on velocity changes or
centrifugal force to bring about separation.
In one type of separator, the air is made to change its direction several times on
its way through a screen or an arrangement of baffles. The heavier droplets of
moisture impinge on the surface of the screen or baffle plate, and run down to
the base of the separator, where they are collected and removed by an
automatic drain trap.
Another type uses centrifugal force to remove the water droplets, by causing
the air to spin so that the drops are thrown to the sides of the outer casing,
where they fall to the bottom of the separator and are once again collected and
removed.
Sometimes, as in FIGURE 9, rather than use a separate device, the separator is
incorporated into the design of the aftercooler. In this type, a baffle and pipe
arrangement, in the separator portion of the equipment, causes the air that
enters to change both its direction and velocity. This results in the moisture
droplets being separated, allowing them to be collected and automatically
drained from the bottom of the separator.
Explain the consequence of an accumulation of dirt on the heat-exchanger surfaces of
an aftercooler.
...................................................................................................................................................
...................................................................................................................................................
________________________________________________________________________________________
24
Teesside University Open Learning (Engineering)
© Teesside University 2011
The air would pass through without adequate cooling and therefore carry extra moisture into
the system.
AIR RECEIVERS
The air receiver is used as a storage reservoir for the overall compressed air
system. However, it will also serve to balance out pulsations in air flow from
the compressor, so providing a continuous pulsation-free supply to the
pneumatic equipment receiving the air. In addition, a certain amount of
cooling will take place in the receiver, causing even more moisture to be
removed from the air supply before it can enter the system.
The size of the air receiver is determined by the rate at which the air is
consumed, and the production capacity of the compressor. There are of course
other factors controlling the size of the receiver, such as the type of capacity
control provided for the compressor and maximum cycling rate; but the air
storage and the ability to supply all system demands at a relatively constant
pressure are the principal determinants.
A certain storage capacity is essential for the fail-safe operation of the items of
equipment connected to the system, in the event of a power failure or an
interruption in supply.
As a general guide to receiver sizing, it can be stated that the volumetric
capacity of the receiver in m3 should be equal to the delivery capacity of the
compressor in m3 min–1.
However, when sizing a suitable receiver, all of the relevant factors should be
considered: if in doubt the compressor manufacturers should be consulted.
Financially it is cheaper to use a receiver that is too large than one that is too
small.
25
Teesside University Open Learning (Engineering)
© Teesside University 2011
Air receivers should be installed outdoors wherever possible and on the
shaded, cooler side of a building. This will promote better cooling, result in
more moisture being separated, and give drier air. If receivers are sited indoors
then good ventilation of the area is advised.
FIGURE 11 shows a typical air receiver.
FIG. 11 Typical Air Receiver
Pressure gauge
Compressed air inlet
Inspection manhole
Supports Drain cock
Compressed air outlet
Pressure relief valve
Receiver shell
26
Teesside University Open Learning (Engineering)
© Teesside University 2011
AIR DRYERS
In many of today's manufacturing processes and in industrial automation, the
presence of any moisture in the compressed air cannot be tolerated. To allow
the air supply to meet such stringent standards, it must undergo a far more
sophisticated process than the normal aftercooling and moisture separation.
The aim of compressed air drying is to lower the pressure dew point (PDP) of
the pressurised air to a value less than that which is likely to occur in the
distribution system or point of use.
The pressure dew point of the compressed air is that temperature at which
water vapour contained in compressed air at a specified pressure (other than
atmospheric pressure) will condense to form liquid water. The dew point at
atmospheric pressure is referred to as atmospheric dew point (ADP).
There are three methods of compressed air drying:
Regenerative Adsorption Drying
The unit will usually consist of two pressure vessels which are filled with some
water adsorbing chemical. Wet compressed air will be passed through one
chamber until the chemical is saturated. The flow of wet air is then diverted
automatically to the second chamber, whilst the saturated chamber is
regenerated, by a coil heater inside the vessel drying the adsorbent chemical or
by passing a charge of ultra dry air through the vessel, to remove the moisture
from the chemical inside. This cycle repeats continually with one vessel
operational and the other regenerating. Adsorption dryers can achieve pressure
dew points down to –20°C for air at a pressure of 7 bar, some will achieve
–50°C dependant upon the type of desiccant used. Common desiccant
materials for adsorption dryers are silica gel or activated alumina.
27
Teesside University Open Learning (Engineering)
© Teesside University 2011
FIGURE 12 shows a typical adsorption dryer system.
FIG. 12 Regenerative Adsorption Dryer
Dry air exit
Purge air
Wet air entry
Vessel being regenerated
Two-way valve
Adsorbing chemical
Vessel drying
air
Coil heater
28
Teesside University Open Learning (Engineering)
© Teesside University 2011
Chemical Absorption Drying
In this type of drier, the moisture in the air, on coming into contact with the
absorbent desiccant, will react chemically and liquidise as opposed to being
adsorbed onto the surface of the desiccant as in the adsorption dryer.
The solution formed by the water and the absorbing chemical falls to the
bottom of the chamber, where it is drained off by an automatic drain trap.
Typical desiccant materials used in absorption dryers are urea lithium and
calcium chloride which must be regularly replenished, normally at monthly
intervals, to compensate for the desiccant used in the drying process.
FIGURE 13 shows a typical chemical absorption dryer system.
FIG. 13 Chemical Absorption Dryer
Access opening for adding desiccant
Dry air exit
Drain outlet
Wet air entry
Desiccant pellets
29
Teesside University Open Learning (Engineering)
© Teesside University 2011
Refrigeration or Chiller Dryers
These units are heat exchangers which will cool the air down to a theoretical
dew point of 1 to 3°C and thus precipitate out the moisture. The system is a
straight mechanical refrigeration unit with one extra facility included: this is a
second heat exchanger in which the outgoing cold air is used to pre-cool the
incoming air supply. This has the effect of warming the outgoing air slightly
to about ambient temperature.
FIGURE 14 shows a typical refrigeration dryer system.
FIG. 14 Refrigeration Dryer System
Wet air entry
Expansion valve
Water separator and drain
Air-to-air heat exchanger
Water separator and drain
Dry air exit
Condenser
Air-to- refrigerant
heat exchanger
30
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
NOTES ________________________________________________________________________________________
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
31
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
SELF-ASSESSMENT QUESTIONS ________________________________________________________________________________________
1. Produce a block diagram of a typical compressor plant installation
showing all essential components in the correct order.
2. With reference to FIGURE 14, simply explain the refrigeration drying
process.
3. List three functions of an air receiver.
4. Describe an ideal location for an air receiver.
5. Explain the main advantage a water-cooled aftercooler has over an air-
blast type.
32
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
NOTES ________________________________________________________________________________________
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
...................................................................................................................................................
33
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
ANSWERS TO SELF-ASSESSMENT QUESTIONS ________________________________________________________________________________________
1. The answer is shown in FIGURE 15
FIG. 15
2. Wet air enters the air-to-air heat exchanger and gives up heat to the cool
air passing out into the system. Condensing moisture is removed and
drained. Air then enters the refrigeration unit where it is cooled, further
condensing moisture is again removed and drained. Finally the air passes
back through the air-to-air heat exchanger, gaining heat from the
incoming air, and passes into the system.
3. Three functions of an air receiver are:
• to store the air
• to remove moisture
• to dampen pulsations.
4. The air receiver should be sited in a cool, shaded location with good
access for maintenance purposes.
5. The main advantage is being able to cool the air to below ambient
temperature and hence remove more moisture.
SilencerFilter Comp. Stage 1 Intercooler
After- cooler
Dryer ReceiverSystem
Atmosphere Comp. Stage 2
34
Teesside University Open Learning (Engineering)
© Teesside University 2011
________________________________________________________________________________________
SUMMARY ________________________________________________________________________________________
At the end of this lesson you should now appreciate:
• the reason why compressors are rated in free-air delivered (FAD)
rather than compressed air, and appreciate that the relationship which
exists between the two is the compression ratio of the machine
concerned
• the relationship between pressure, temperature and the moisture-
carrying capacity of air
• the fact that siting a compressor in a humid location will cause
problems with moisture carry-over, and the methods used to
minimise this problem
• that different types of air dryers are available, and their basic
constructional details
• the order and arrangement of compressor plant components.
35
Teesside University Open Learning (Engineering)
© Teesside University 2011