technical report/powerpoint presentatiom
Step 4: Implement a Subset of Selected Security Controls
Task: View this topic
Last Visited Jun 18, 2021 5:40 PM
AY
Now that the moderate-impact security
controls have been selected, you need to
describe how to implement them. The good
news is that the controls have been divided
among other CARS team members, leaving
only a small subset for you to complete on
your own.
Using the themes of access, authentication,
and authorization, focus on the access
control (AC) and planning (PL) families. The
following controls have been assigned to you:
AC-7 Unsuccessful Logon Attempts
AC-8 System Use Notification
PL-8 Information Security Architecture
Specifically, you need to provide details on
how each of the following security controls
will be implemented. To further define each
of these implementations, complete the
following:
AC-7 System Use Notification
For security control AC-7, define the
following parameters associated with AC-7:
1. The number of consecutive invalid
logon attempts by a user before the
user is locked out.
2. The time period in which the number of
consecutive logon attempts is
considered.
3. The time period the account is locked
when the number of consecutive invalid
logons criteria is met.
4. The manner in which the account is
unlocked (e.g., administrative
intervention versus automatic).
You do not need to write the actual code to
implement the control.
AC-8 Unsuccessful Logon Attempts
For the AC-8 security control, draft the
message or warning banner that will be
displayed to users before granting access to
the system. This banner should provide
privacy and security notices aligned with
directives or other policies as applicable. The
message should be unique to your system
design but follow approaches similar to
government, university, or other
organizational access messages.
PL-8 Information Security
Architecture
Resources for Creating System
Architecture Diagrams
Microsoft PowerPoint
Microsoft Word
Microsoft Visio
Apache OpenOffice Impress
The information security architecture is a
fundamental document describing the overall
system security architecture and the defense-
in-depth approaches to defending the
system. For this control, the following
components should be included:
1. architectural description in the form of
a high-level logical view (see the figure
titled “Notional High Level Logical
Architectural View”);
2. system categorization (in this case,
moderate-impact);
3. minimum security requirements, based
on the moderate-impact categorization;
4. security controls (i.e., the prioritized list
you developed in the previous step);
and
5. a description of how you will use
defense-in-depth , layered
approaches to allocate security
safeguards and mechanisms.
Notional High Level Logical Architectural
View
Save the Information Security Architecture as
well as the descriptions you created of the
AC-7 and AC-8 security controls in a Word
document to include in your technical report
later in this project.
Security Architecture Across
Organizations
The NIST documents are used by US
government agencies, contractors, and
others. Other documents providing
security control implementation exist
for non-federal systems and
organizations, but they provide similar
guidance. For example, “Protecting
Controlled Unclassified Information in
Nonfederal Systems and Organizations”
(NIST SP-800-171) has been applied
to health care organizations, small
businesses, and other organizations
outside the federal government.
Banking and the finance groups rely on
the Payment Card Industry (PCI)
Security Controls Council. Founded by
the world’s leading global payment
brands, the council develops and drives
adoption of security standards and
resources for safe payments worldwide.
Their document library (PCI Security
Standards Council, n.d.) includes a
framework of specifications, tools,
measurements and support resources
to ensure the safe handling of
cardholder information.
Other countries have processes similar
to those defined by NIST. The European
Union has its own risk management
framework, procedures, and guidelines
for secure information systems. “How
to Implement Security Controls for an
Information Security Program at CBRN
Facilities” (O’Neil et al., 2015) is a
technical report that provides guidance
for instituting security controls for
chemical, biological, radiological, and
nuclear facilities.
References
PCI Security Standards Council,
Document Library. (n.d.).
Retrieved June 08, 2020, from
https://www.pcisecuritystandar
ds.org/document_library
O'Neil L., C.S. Glantz, J.D. Lenaeus, J.L.
Bryant, G.P. Landine, R.M.
Leitch, and J. Lewis, et al.
(2015). How to Implement
Security Controls for an
Information Security Program
at CBRN Facilities. PNNL-
25112. Richland, WA: Pacific
Northwest National
Laboratory. Retrieved from
https://www.pnnl.gov/main/pu
blications/external/technical_r
eports/PNNL-25112.pdf
Professionals in the Field
Activity Details
6/18/21, 6:13 PM Page 1 of 1