need help for the questions
The circumstances of failure
A fully loaded container was being lifted when a worker noticed a tear along the joints of the panel.
There was no general collapse, and the cargo remained inside
The container was removed from service and cargo was transported to another one.
Within few weeks similar events (10 before investigation started) occurred scattered around the world
Max weight 30,480kg Length 12.19 m Distance of tear from end 1.25m Panels held together with 48 rivets
OTHER DATA
Major observation?
No deformation of panel
Information received from manufacturer
Rivets were delivered on H2 condition Kept in store until withdrawn anything
between few days to a month.
SEM OF THE RIVETS
Conclusions?
HV test (Vickers Hardness)
Where should the hardness test be performed?
Compression tests on a fully annealed rivet. REDUCTION IN THICKNESS
Anneale d
10% 20% 30% 40% 50% 60% 70% 80% 90%
HV 38.1 53.2 60.3 63.9 67.2 70.7 73.9 75.9 78.8 81.0
Solution treated 2h 800K, quenched and aged for 5 days at 290K
Sample HV Hardness as quenched
HV Hardness after 5 days of ageing at 290K RT
1 56.2 98.5
2 55.3 101
3 52.0 92.7
4 54.4 95.6
Mean 54.5 97.0