first call resolution to at least 75% of calls
Resolve minimum 90% of inquiries within 5 days
Bank was monitoring the data on number of people who were unable to get answers from CCS.
(QA) department conducts regular inspections of recorded conversations between the callers and representatives. A rating based on the scale of 1-5 is assigned to the calls based on friendliness, and suitable advice given to the callers. The table below shows the description of ratings:
It has been observed that the quality check results of the two QA analysts, vary sometimes. Therefore data for 20 voice recordings was
Ratings Definition
1 Perfect response
2 Good response
3 Average response
4 Poor response
5 Very bad response
collected to verify the repeatability and reproducibility of QA activities. Table 2 shows the results of their assessments for each voice recording.
A couple of other problems with CCS are their inability to hold on to the experienced workforce and the time it takes to hire experienced individuals. CCS decides to hire Six Sigma methodology to help them improve the call center operations and to improve the performance to a level that is acceptable to the client. CCS also wants to ensure that the Average Handle Time is maintained during the course of this project. CCS has 6-8 months to turn around the performance of the company
Data Tables
Table 1
Month Number of Reps Number of Calls AHT First Calls Resolution 5 Day Resolution FCR % 5DR % Jan-14 20 22,858 4.17 16,458 15,822 72.0% 69.2% Feb-14 20 28,963 3.40 22,910 22,092 79.1% 76.3% Mar-14 20 23,070 4.91 15,826 16,697 68.6% 72.4% Apr-14 19 29,933 2.46 26,375 21,454 88.1% 71.7% May-14 19 26,633 4.49 15,554 19,663 58.4% 73.8% Jun-14 19 27,638 3.97 21,266 20,788 76.9% 75.2% Jul-14 19 24,553 2.93 23,167 20,136 94.4% 82.0% Aug-14 20 29,897 3.27 19,913 22,544 66.6% 75.4% Sep-14 20 23,418 4.05 16,346 18,788 69.8% 80.2% Oct-14 21 22,901 3.89 18,756 14,910 81.9% 65.1% Nov-14 20 22,250 5.59 15,308 15,301 68.8% 68.8% Dec-14 20 27,482 4.02 16,324 22,585 59.4% 82.2% Jan-15 20 24,599 4.67 20,366 17,138 82.8% 69.7% Feb-15 20 26,413 3.14 25,281 15,187 95.7% 57.5% Mar-15 19 24,840 4.87 16,221 17,691 65.3% 71.2% Apr-15 19 27,011 3.43 17,368 17,708 64.3% 65.6% May-15 18 21,166 4.85 17,400 14,749 82.2% 69.7% Jun-15 18 28,871 3.62 26,417 21,618 91.5% 74.9% Jul-15 17 24,515 4.19 21,003 19,949 85.7% 81.4% Aug-15 19 21,244 3.73 14,573 14,191 68.6% 66.8% Sep-15 20 29,950 4.02 23,766 22,833 79.4% 76.2% Oct-15 20 21,387 6.08 14,950 14,990 69.9% 70.1% Nov-15 20 23,906 3.57 18,848 19,047 78.8% 79.7% Dec-15 20 27,199 4.03 24,115 24,258 88.7% 89.2% HISTORICAL BASELINE DATA (Table 1)
Table 2
Voice Sample Master Appraiser X Trial 1 X Trial 2 Y Trial 1 Y Trial 2 1 3 3 2 3 3 2 2 2 2 2 2 3 2 2 2 2 2 4 4 4 3 4 4 5 2 1 1 1 1 6 5 5 4 5 5 7 4 4 4 5 4 8 3 3 2 3 3 9 3 3 3 3 3 10 4 4 5 4 4 11 2 2 1 2 2 12 3 3 3 3 3 13 5 5 4 5 5 14 2 2 2 2 2 15 2 2 2 2 2 16 2 2 2 2 2 17 2 2 2 2 2 18 4 4 3 4 3 19 3 3 3 3 3 20 2 2 2 2 2 Table 2
Exercises
Read case study then answer the following questions
Exercise 1
Process capability Indices
Using the data given in Table 1, determine the process capability indices for performance metric. Provide the appropriate interpretation for the process capability indices drawn, based on the available data.
A. ‘First Call Resolution’. The specification limits for the FCR are; LSL=75% and USL=100%. B. ‘5 Day Resolution’. The specification limits for the 5DR are; LSL=90% and USL=100%.
Exercise 2
A. What kind of data is shown in Table 2? Which method would you use for measurement system analysis (MSA) to verify the repeatability and reproducibility of QA results? Conduct the appropriate MSA. B. Determine the potential causes why CCS fails to meet First Call Resolution targets consistently. C. Brainstorm and propose solutions for elimination of causes for failure to meet FCR targets.
Exercise 3
FMEA
Identify potential failure modes and their effects for the solutions proposed in Exercise 2 using learning on FMEA.