Safety and Efficacy of Bronchoalveolar Lavage Using a Laryngeal Mask Airway in Cases of Acute Hypoxaemic
Respiratory Failure with Diffuse Lung Infiltrates
Takafumi Matsumoto, Yoko Sato, Satoshi Fukuda, Shinshu Katayama, Yuya Miyazaki, Makoto Ozaki and Toru Kotani
Abstract
Objective Fibre-optic bronchoscopy with bronchoalveolar lavage (FOB-BAL) is an important tool for diag- nosing and selecting treatment for acutely hypoxaemic patients with diffuse lung infiltrates. However, FOB- BAL carries a risk of significant hypoxaemia and subsequent tracheal intubation during and after the proce- dure. The application of FOB-BAL using a laryngeal mask airway (LMA) in combination with continuous positive airway pressure (CPAP) may minimize the incidence of hypoxaemia; however, the safety and effi- cacy of this procedure have not been investigated. Methods A retrospective chart review was performed from April to September 2013. Data regarding the re- covered volume of BAL fluid, incidence of tracheal intubation within eight hours after the completion of FOB-BAL, respiratory and haemodynamic parameters and treatment modifications were collected for the evaluation. Results Ten trials of FOB-BAL using an LMA and CPAP were performed in nine patients with severe acute hypoxaemia associated with diffuse lung infiltrates. The BAL fluid recovery rate was 56%, and the pro- cedure was completed without subsequent complications. In addition, the percutaneous arterial oxygen satura- tion decreased to 95.7%±3.8%, although it was never lower than 90.0% during the procedure, and no patients required intubation. Furthermore, the arterial blood pressure significantly but transiently decreased due to se- dation, and the procedure yielded diagnostic information in all nine patients. Conclusion FOB-BAL using LMA and CPAP appears to be safe and effective in patients who develop se- vere acute hypoxaemia.
Key words: bronchoalveolar lavage, continuous positive airway pressure, fibre-optic bronchoscopy, laryngeal mask airway, sedation
(Intern Med 54: 731-735, 2015) (DOI: 10.2169/internalmedicine.54.2686)
Introduction
In acutely hypoxaemic patients with diffuse pulmonary infiltrates, it is important to establish the specific cause of pulmonary disease so that appropriate therapy may be pro- vided immediately. Fibre-optic bronchoscopy with bron- choalveolar lavage (FOB-BAL) is an important tool for di- agnosing diffuse pulmonary infiltrates (1). Although FOB- BAL is generally considered to be safe (2), it is well known
that the arterial blood oxygen saturation usually decreases during and/or after the procedure (3-6). Therefore, FOB- BAL is contraindicated in non-intubated, severely hypoxae- mic patients (7). Positive end-expiratory pressure ameliorates hypoxaemia by preventing alveolar collapse, although some type of airway management is necessary for its use. While tracheal intubation is the most reliable airway management technique, certain complications may occur during intuba- tion and/or after extubation (8). Therefore, the development of a strategy other than intubation to prevent hypoxaemic
Department of Anesthesiology and Intensive Care Medicine, Tokyo Women’s Medical University, Japan Received for publication February 12, 2014; Accepted for publication August 17, 2014 Correspondence to Dr. Toru Kotani, [email protected]
Intern Med 54: 731-735, 2015 DOI: 10.2169/internalmedicine.54.2686
732
events during FOB-BAL is required. The laryngeal mask airway (LMA) is a supraglottic air-
way device that provides an end-to-end airtight seal around the larynx and maintains effective gas exchange (9, 10). An advantage of LMA is that it can be blindly inserted without laryngoscopy; thus, cardiovascular responses to the introduc- tion of an LMA are less severe than those induced by tra- cheal intubation (11, 12). The LMA technique for both spontaneous and controlled ventilation is reportedly both safe and effective (13), and a recent study demonstrated that FOB-BAL can be safely and effectively performed with an LMA in immunosuppressed patients with pneumonia and se- vere hypoxaemia (14).
In our intensive care unit, FOB-BAL is routinely per- formed using an LMA in combination with continuous posi- tive airway pressure (CPAP) under light sedation in acutely hypoxaemic patients with diffuse lung infiltrates in order to prevent hypoxaemic events during and after the examination. We subsequently conducted a retrospective case-series study of FOB-BAL to demonstrate its safety and efficacy.
Materials and Methods
A retrospective chart review was performed from April to September 2013. Data were collected for patients with dif- fuse pulmonary infiltrates who exhibited acute hypoxaemic respiratory failure requiring oxygen therapy or non-invasive positive airway pressure ventilation (NPPV) and who under- went FOB-BAL for diagnostic or therapeutic reasons. Data for demographic variables, the ratio of arterial blood oxygen saturation to the fraction of inspired oxygen under CPAP of 5 cm H2O, Simplified Acute Physiological Score II and un- derlying diseases were also obtained. NPPV was applied us- ing a ventilator (Respironics V60; Respironics California, Carlsbad, USA) via a full-face mask. Local research ethics committee approval was received for the retrospective re- view of the patients.
FOB-BAL was performed according to the standard pro- cedures in place at our intensive care unit. Briefly, none of the patients had a contraindication to the insertion of an LMA (15) before undergoing the procedure. One physician was in charge of sedation and haemodynamic management. A flexible fibre-optic bronchoscope (BF-P60; Olympus, To- kyo, Japan), LMA (LMA Supreme; Teleflex Medical, San Diego, USA or i-gel; Intersurgical, Wokingham, Berkshire, UK), topical anaesthetic (4% lidocaine hydrochloride), seda- tives (propofol and fentanyl), vasopressor (phenylephrine hy- drochloride) and warm sterile 0.9% saline solution for BAL were prepared prior to the examination. A properly sized LMA (size 3 or 4) was chosen for each patient and lubri- cated with 2% lidocaine gel. The medical team was pre- pared for tracheal intubation and invasive ventilation while performing the procedure.
An electrocardiogram, non-invasive and/or invasive blood pressure measurements, percutaneous arterial oxygen satura- tion and respiratory rate were continuously monitored during
the procedure. Initially, CPAP was applied via a full-face mask. The positive end-expiratory pressure was set at 5 cm H2O or the pre-bronchoscopy level. The fraction of inspired oxygen was increased to 1.0. Topical anaesthesia was ap- plied to the oral cavity and larynx by thoroughly spraying 4% lidocaine hydrochloride. Sedation was initiated by the incremental administration of a combination of 25 μg of fentanyl and 20 to 30 mg of propofol followed by the infu- sion of 1 to 3 mg/kg/h of propofol to maintain spontaneous breathing. After confirming the patient’s unconsciousness, the LMA was inserted and connected to the ventilator via a swivel connector (Sontek Suction-Safe Swivel Y; Sontek Medical, Hingham, USA). Mechanical ventilation was ap- plied in the spontaneous/timed mode in order to maintain the minute volume in case of suppression of spontaneous breathing secondary to sedation. The bronchoscope was in- troduced through the swivel connector. After examining the tracheobronchial tree and providing topical anaesthesia, the tip of the bronchoscope was wedged into the subsegmental area with the most severe X-ray abnormalities. The bronchus was instilled with sterile saline (five 20-mL aliquots) and gently aspirated. The obtained fluid was pooled, processed and immediately sent to the laboratory for cytologic and mi- crobiological examinations. The LMA was removed when the patient had completely emerged from anaesthesia and was able to obey commands. After removing the LMA, NPPV was continued with a full-face mask. The fraction of inspired oxygen was gradually decreased to the pre- bronchoscopy level. Patients who did not require NPPV be- fore the examination were switched back to conventional oxygen therapy.
The rate of intubation within eight hours after the com- pletion of FOB-BAL and the changes in the respiratory rate, mean arterial pressure and heart rate just before sedation, during FOB-BAL and one hour after FOB-BAL were re- corded and compared. The lowest arterial blood oxygen saturation noted during the procedure was recorded, and the volume of BAL aspirated was documented as a percentage of the instilled aliquot. Treatment modifications based on the BAL analysis were also evaluated.
The results are expressed as the mean ± standard devia- tion (95% confidence interval). An analysis of variance was used to compare respiratory and haemodynamic parameters obtained just before sedation and during and after the FOB- BAL procedure. A p value of <0.05 was considered to be statistically significant.
Results
Data for 14 cases of FOB were collected during the study period. Ten FOB-BAL procedures using an LMA and CPAP were performed in nine consecutive patients. The character- istics of the patients are shown in Table 1. Eight patients (89%) received immunosuppressive therapy for renal trans- plantation (n=5), rheumatoid arthritis (n=2) and rapidly pro- gressive glomerulonephritis (n=1). The mean ratio of arterial
Intern Med 54: 731-735, 2015 DOI: 10.2169/internalmedicine.54.2686
733
Table 1. Patient Characteristics
Demographic data No. of patients 9 Age (years) 67.5 ± 12.7 (57.7-77.3) Gender ratio (F/M) 2/7 BMI (kg/m2) 21.5 ± 2.5 (19.6-23.5)
Physiological data SAPSII 39.9 ± 10.3 (31.9-47.9) PaO2/FiO2 206.7 ± 55.5 (170.0-246.4)
Underlying diseases and comorbidities Immunocompromised
Renal transplantation 5 (55.6%) Rheumatoid arthritis 2 (22.2%) Rapidly progressive glomerulonephritis 1 (11.1%)
Haematological malignancy 1 (11.1%) Use of vasopressor 1 (11.1%) Use of NPPV prior to FOB-BAL 6 (66.7%) PEEP (cm H2O) 6.7 ± 1.3 (5.4-8.0)
The data are presented as the mean ± standard deviation (95% confidence interval) or n (%). F: female, M: male, BMI: body mass index, SAPS II: Simplified Acute Physiological Score II, PaO2/FiO2: ratio of arterial blood oxygen saturation to fraction of inspired oxygen, NPPV: non-invasive positive airway pressure ventilation, FOB-BAL: fibre-optic bronchoscopy with bronchoalveolar lavage, PEEP: positive end-expiratory pressure
blood oxygen saturation to the fraction of inspired oxygen before FOB-BAL was 206.7±55.5 (170.0-246.4) mmHg. NPPV was performed in six patients (67%) prior to FOB- BAL, with a positive end-expiratory pressure of 6.7±1.3 (5.4-8.0) cm H2O.
The duration of FOB-BAL was 20.3±3.7 (17.6-30.0) min- utes. The total doses of propofol and fentanyl were 129.9± 59.6 (93.6-166.1) mg and 102.5±18.4 (89.3-115.7) μg, re- spectively. The mean positive end-expiratory pressure during the procedure was 6.5±1.4 (5.4-7.5) cm H2O. The spontane- ous/timed mode was temporarily applied with an inspiratory positive airway pressure of 14.0±0.7 (11.7-16.2) cm H2O in four patients (44.4%). No patients required tracheal intuba- tion within eight hours after FOB-BAL. Only one patient was intubated three days after FOB due to progression of the underlying disease.
The procedure was completed without subsequent compli- cations in all cases. The cardiorespiratory parameters ob- tained just before sedation, during FOB-BAL and one hour after FOB-BAL are shown in Figure. The changes in the respiratory rate and heart rate induced by the procedure did not reach statistical significance. In contrast, the mean arte- rial blood pressure during the procedure significantly de- creased. However, the haemodynamic changes were modest and transient, with the use of phenylephrine hydrochloride. The mean arterial oxygen saturation was 95.7%±3.8% (93.0%-98.4%), and no patients exhibited an arterial blood oxygen saturation of <90.0% during the procedure. Two pa- tients were switched back to oxygen therapy after the proce- dure. No other adverse events were noted, such as laryn- gospasms, coughing, haemorrhage, arrhythmia or pneumot- horax.
The results of FOB-BAL are shown in Table 2. The mean percentage volume of recovered BAL fluid was 56.1%±
11.1% (48.1-64.0%). The procedure yielded diagnostic in- formation for nine patients (90%). Pneumocystis pneumonia was diagnosed in eight patients, and acute exacerbation of collagen vascular disease-associated interstitial pneumonia was diagnosed in one case. Treatment was modified in nine procedures based on the results of the BAL analysis (90%).
Discussion
In this study, we found that FOB-BAL using an LMA and CPAP prevented hypoxaemic events and major compli- cations, including tracheal intubation, and contributed to treatment modification, suggesting that this technique is safe and effective in patients with severe acute hypoxaemia and diffuse lung infiltrates. The procedure was well tolerated in all patients. This is the first study to assess the feasibility of FOB-BAL using an LMA in combination with CPAP under light sedation.
The occurrence of hypoxaemia during FOB has been re- ported in several studies (3, 4, 6). Such hypoxaemia may be caused by partial airway obstruction induced by the bron- choscope, airway suction, anaesthetics or presence of lavage fluid in the alveoli (4, 16). Mechanical ventilation with air- way management must be performed in patients undergoing FOB-BAL to ameliorate hypoxaemia and maintain adequate gas exchange during the procedure, and tracheal intubation is the most reliable method for achieving these goals. How- ever, various complications may occur, such as cardiovascu- lar responses to tracheal intubation, with subsequent vocal dysfunction and/or laryngeal disorders after extuba- tion (8, 17, 18). In the current study, the arterial blood oxy- gen saturation was maintained above 91% in all patients.
NPPV delivers positive pressure without the use of an ar- tificial airway and is a safe and effective method for amelio- rating hypoxaemia in patients with acute respiratory fail- ure (19, 20). The feasibility and safety of NPPV using a full-face mask for FOB-BAL has been reported in previous studies (5, 21-28). However, in the majority of these studies, bronchoscopy was performed with only topical anaesthesia (5, 22-24, 26, 27), and essential problems included low tol- erance to mask fitting and FOB-BAL in conscious patients. Patient agitation may lead to desaturation and possibly com- promise the success of the FOB-BAL procedure (25). One previous study described the difficulties in performing bron- choscopy without sedation, with analgosedation used in all patients (14). LMAs provide upper airway patency even in cases of deep sedation or general anaesthesia, which subse- quently ensures excellent visualization of the vocal cords, glottis and trachea without decreasing the airway diameter as do tracheal tubes, thus avoiding increases in airway resis- tance (9, 10, 29-31). In our procedure, the use of appropri- ate sedation and positive pressure ventilation with an LMA helped to yield diagnostic information by allowing for the recovery of a sufficient volume of bronchoalveolar lavage fluid (BALF).
It is important to minimize the cardiorespiratory response
Intern Med 54: 731-735, 2015 DOI: 10.2169/internalmedicine.54.2686
734
Figure. Variation in cardiorespiratory parameters. The respiratory rate (panel A ), heart rate (pan- el B ) and mean arterial pressure (panel B ) were recorded as follows: just before sedation (before), during fibre-optic bronchoscopy with bronchoalveolar lavage (during) and one hour after fibre-optic bronchoscopy with bronchoalveolar lavage (one hour after). The data are expressed as the mean ± standard deviation. *p<0.05 for comparison with the baseline data (obtained just before sedation). The lowest value of each parameter observed during the procedure was recorded. RR: respiratory rate, HR: heart rate, MAP: mean arterial pressure
Table 2. Characteristics and Results of Fibre- optic Bronchoscopy with Bronchoalveolar Lavage
Duration of FOB-BAL (min) 20.3 ± 3.7 (17.6-30.0) No. of FOB-BAL 10 (100%) BAL Volume instilled (mL) 100 Volume recovered (mL) 56.1 ± 11.1 (48.1-64.0) Diagnostic yield of FOB-BAL 9 (90%)
The data are presented as the mean ± standard deviation (95% confidence interval) or n (%). FOB-BAL: fibre-optic bronchoscopy with bronchoalveolar lavage
during the procedure in severely hypoxaemic patients, and inducing coughing is critical in subjects on long-term steroid therapy. In our strategy, the application of topical anaesthe- sia to the oral cavity followed by the maintenance of anaes- thesia using propofol and fentanyl resulted in better toler- ance of FOB. The administration of propofol enables the level of sedation to be adjusted, with rapid elimination of the drug. The majority of previous studies have used this medication to both insert the LMA (15, 32) and perform FOB (9, 14, 21, 25, 33). Fentanyl is a strong analgesic and antitussive that can be employed to reduce the amount of propofol required. In general, the amount of anaesthetics or analgesics needed to establish an LMA is less than that re- quired for tracheal intubation. Recent studies have also dem- onstrated the occurrence of alveolar hypoventilation, as esti- mated by an increase in the partial pressure of carbon diox- ide, during FOB under sedation (21, 34). In our procedure, mechanical ventilation is immediately applied to maintain the appropriate minute volume if the sedatives suppress the patient’s spontaneous breathing. Furthermore, the mean per- centage of BALF volume recovered was higher in this re- port than in previous studies involving the use of NPPV- assisted FOB-BAL (21, 25, 28). Positive pressure ventilation may allow for a sufficient volume of BALF to be recovered,
thus providing diagnostic information. Our procedure is associated with some limitations. It
should be emphasized that well-trained physicians are needed to perform both bronchoscopy and anaesthesia, and the procedure should be carried out in the intensive care unit in order to allow for close monitoring. Therefore, our results may not be generalizable to other settings. In addition, this was a retrospective observational study, and the sample size was small. Although we included patients consecutively dur- ing the study period, the background characteristics of the patients were biased. Furthermore, the use of blood gas analyses under CPAP of 5 cm H2O may reflect a higher ra- tio of arterial blood oxygen tension to the fraction of in- spired oxygen before FOB-BAL compared to that seen in previous studies. A prospective study is therefore warranted to confirm the advantages of LMA over tracheal intubation under the same conditions.
In conclusion, the use of LMA in combination with CPAP under light sedation can be used to provide a safe and effective FOB-BAL procedure in patients with severe acute hypoxaemic respiratory failure.
The authors state that they have no Conflict of Interest (COI).
References
1. Wells AU. The clinical utility of bronchoalveolar lavage in diffuse parenchymal lung disease. Eur Respir Rev 19: 237-241, 2010.
2. Facciolongo N, Patelli M, Gasparini S, et al. Incidence of compli- cations in bronchoscopy. Multicentre prospective study of 20,986 bronchoscopies. Monaldi Arch Chest Dis 71: 8-14, 2009.
3. Albertini RE, Harrell JH 2nd, Kurihara N, Moser KM. Arterial hy- poxemia induced by fiberoptic bronchoscopy. JAMA 230: 1666- 1667, 1974.
4. Matsushima Y, Jones RL, King EG, Moysa G, Alton JD. Altera- tions in pulmonary mechanics and gas exchange during routine fi- beroptic bronchoscopy. Chest 86: 184-188, 1984.
Intern Med 54: 731-735, 2015 DOI: 10.2169/internalmedicine.54.2686
735
5. Antonelli M, Conti G, Rocco M, et al. Noninvasive positive- pressure ventilation vs. conventional oxygen supplementation in hypoxemic patients undergoing diagnostic bronchoscopy. Chest 121: 1149-1154, 2002.
6. Lindholm CE, Ollman B, Snyder JV, Millen EG, Grenvik A. Car- diorespiratory effects of flexible fiberoptic bronchoscopy in criti- cally ill patients. Chest 74: 362-368, 1978.
7. Goldstein RA, Rohatgi PK, Bergofsky EH, et al. Clinical role of bronchoalveolar lavage in adults with pulmonary disease. Am Rev Respir Dis 142: 481-486, 1990.
8. Pingleton SK. Complications of acute respiratory failure. Am Rev Respir Dis 137: 1463-1493, 1988.
9. Dich-Nielsen JO, Nagel P. Flexible fibreoptic bronchoscopy via the laryngeal mask. Acta Anaesthesiol Scand 37: 17-19, 1993.
10. Fadaizadeh L, Hosseini MS. Laryngeal mask airway in interven- tional bronchoscopy for tracheal lesions. Acta Anaesthesiol Taiwan 51: 137, 2013.
11. Hickey S, Cameron AE, Asbury AJ. Cardiovascular response to insertion of Brain’s laryngeal mask. Anaesthesia 45: 629-633, 1990.
12. Wilson IG, Fell D, Robinson SL, Smith G. Cardiovascular re- sponses to insertion of the laryngeal mask. Anaesthesia 47: 300- 302, 1992.
13. Verghese C, Brimacombe JR. Survey of laryngeal mask airway us- age in 11,910 patients: safety and efficacy for conventional and nonconventional usage. Anesth Analg 82: 129-133, 1996.
14. Hilbert G, Gruson D, Vargas F, et al. Bronchoscopy with bron- choalveolar lavage via the laryngeal mask airway in high-risk hy- poxemic immunosuppressed patients. Crit Care Med 29: 249-255, 2001.
15. Asai T, Morris S. The laryngeal mask airway: its features, effects and role. Can J Anaesth 41: 930-960, 1994.
16. British Thoracic Society Bronchoscopy Guidelines Committee aSoSoCCoBTS. British Thoracic Society guidelines on diagnostic flexible bronchoscopy. Thorax 56 (Suppl 1): i1-i21, 2001.
17. Braude N, Clements EA, Hodges UM, Andrews BP. The pressor response and laryngeal mask insertion. A comparison with tracheal intubation. Anaesthesia 44: 551-554, 1989.
18. Zimmert M, Zwirner P, Kruse E, Braun U. Effects on vocal func- tion and incidence of laryngeal disorder when using a laryngeal mask airway in comparison with an endotracheal tube. Eur J An- aesthesiol 16: 511-515, 1999.
19. Brochard L. Noninvasive ventilation for acute respiratory failure. JAMA 288: 932-935, 2002.
20. Nava S, Hill N. Non-invasive ventilation in acute respiratory fail- ure. Lancet 374: 250-259, 2009.
21. Baumann HJ, Klose H, Simon M, et al. Fiber optic bronchoscopy in patients with acute hypoxemic respiratory failure requiring non-
invasive ventilation--a feasibility study. Crit Care 15: R179, 2011. 22. Agarwal R, Khan A, Aggarwal AN, Gupta D. Bronchoscopic lung
biopsy using noninvasive ventilatory support: case series and re- view of literature of NIV-assisted bronchoscopy. Respir Care 57: 1927-1936, 2012.
23. Antonelli M, Conti G, Riccioni L, Meduri GU. Noninvasive positive-pressure ventilation via face mask during bronchoscopy with BAL in high-risk hypoxemic patients. Chest 110: 724-728, 1996.
24. Antonelli M, Pennisi MA, Conti G, et al. Fiberoptic bronchoscopy during noninvasive positive pressure ventilation delivered by hel- met. Intensive Care Med 29: 126-129, 2003.
25. Clouzeau B, Bui HN, Guilhon E, et al. Fiberoptic bronchoscopy under noninvasive ventilation and propofol target-controlled infu- sion in hypoxemic patients. Intensive Care Med 37: 1969-1975, 2011.
26. Da Conceicao M, Genco G, Favier JC, Bidallier I, Pitti R. [Fi- beroptic bronchoscopy during noninvasive positive-pressure venti- lation in patients with chronic obstructive lung disease with hy- poxemia and hypercapnia]. Ann Fr Anesth Reanim 19: 231-236, 2000.
27. Heunks LM, de Bruin CJ, van der Hoeven JG, van der Heijden HF. Non-invasive mechanical ventilation for diagnostic broncho- scopy using a new face mask: an observational feasibility study. Intensive Care Med 36: 143-147, 2010.
28. Maitre B, Jaber S, Maggiore SM, et al. Continuous positive air- way pressure during fiberoptic bronchoscopy in hypoxemic pa- tients. A randomized double-blind study using a new device. Am J Respir Crit Care Med 162: 1063-1067, 2000.
29. Birmingham B, Mentzer SJ, Body SC. Laryngeal mask airway for therapeutic fiberoptic bronchoscopic procedures. J Cardiothorac Vasc Anesth 10: 519-520, 1996.
30. Brimacombe J. The advantages of the LMA over the tracheal tube or facemask: a meta-analysis. Can J Anaesth 42: 1017-1023, 1995.
31. Brimacombe J, Tucker P, Simons S. The laryngeal mask airway for awake diagnostic bronchoscopy. A retrospective study of 200 consecutive patients. Eur J Anaesthesiol 12: 357-361, 1995.
32. Brown GW, Patel N, Ellis FR. Comparison of propofol and thio- pentone for laryngeal mask insertion. Anaesthesia 46: 771-772, 1991.
33. Grendelmeier P, Tamm M, Pflimlin E, Stolz D. Propofol sedation for flexible bronchoscopy: randomized, non-inferiority trial. Eur Respir J 43: 591-601, 2014.
34. Dreher M, Ekkernkamp E, Storre JH, Kabitz HJ, Windisch W. Se- dation during flexible bronchoscopy in patients with pre-existing respiratory failure: Midazolam versus Midazolam plus Alfentanil. Respiration 79: 307-314, 2010.
Ⓒ 2015 The Japanese Society of Internal Medicine http://www.naika.or.jp/imonline/index.html