Networking lab
NETW204 Class Project
This project includes three phases. You need to complete Phase I before moving on to Phase II.
Likewise, you need to complete Phase II before moving on to Phase III or the final phase in the
project.
Hi-tech Net Corp. is operating in three locations in the United States. Their main office is
located in New York, NY. They have two branch offices located in Chicago, IL and Sacramento,
CA.
You have just been hired as Hi-tech Net Corp.’s consulting engineer to implement their network
infrastructure. Both branch offices will be directly connected to the main office in NY via a
leased line circuit (point-to-point serial connection).
New York’s Office IP Information
The main office has four LAN segments: Executive, Engineering, Services, and
Native&Management. Each LAN segment is identified by a VLAN number as seen below. For
example:
Executive: VLAN 15
Engineering: VLAN 25
Services: VLAN 35
Native&Management: VLAN 99
The organization is using the following network address in NY: 10.150.0.0/16.
Executive: 60 computers only including future growth in this number
Engineering: 80 computers only including future growth in this number
Services: 115 computers including future growth in this number
Native&Management: 12 computers including future growth in this number
*** Future growth means that we already take growth into consideration. Do not try to
estimate or add more IP addresses than necessary to avoid getting an incorrect subnet.
Illinois’ Office IP Information
The IL branch has three LAN subnets with 45 IP addresses on each subnet. They use the
following network address to obtain the required IL subnets: 10.150.100.0 /24.
California’s Office IP Information
The CA branch has three LAN subnets with 25 IP addresses on each subnet. They use the
following network address to obtain the required CA subnets: 10.150.200.0 /25.
PHASE I (20 points total)—Due Week 3
Tasks to Do.
Task 1: Subnet the 10.150.0.0/16 network for NY and assign the first subnets to Services
followed by Engineering. You may need to re-subnet for Executive and Native&Management
subnets to avoid wasting IP addresses. Ensure that you re-subnet only the first unused subnet
and nothing else. Assign the subnets to Executive and Native&Management. (5 points)
New York Office IP IP Address Range New Subnet Mask New Network Address
VLAN 15-Executive
VLAN 25-Engineering
VLAN 35-Services
VLAN 99-
Native&Management
Task 2: Subnet the 10.150.100.0 /25 network for IL and assign the last IP address on the three
subnets to the Loopback 1, Loopback 2, and Loopback 3 interfaces of the router. We will use a
loopback or virtual interface to simulate the LAN subnets. This will speed up configuration and
allows us to create our topology without rewiring. (3 points)
Illinois Branch IP IP Address Range New Subnet Mask New Network Address
Loopback 1
Loopback 2
Loopback 3
Task 3: Subnet the 10.150.200.0 /25 network for CA and assign the last IP address on the three
subnets to the Loopback 1, Loopback 2, and Loopback 3 interfaces of the router. We will use a
loopback or virtual interface to simulate the LAN subnets. This will speed up configuration and
allows us to create our topology without rewiring. (3 points)
California Branch IP IP Address Range New Subnet Mask New Network Address
Loopback 1
Loopback 2
Loopback 3
Task 4: Use the following network address (10.1.255.0/25) to find the WAN subnets between
NY and IL and NY and CA respectively. Note that there should only be two IP addresses per
subnet for each WAN link. Assign the first WAN subnet to NY to IL and the second WAN subnet
to NY to CA. (2 points)
WAN Subnets IP Address Range New Subnet Mask New Network Address
NY to IL
NY to CA
Task 5: Use Microsoft Visio to design the current network topology. Remember to use
Loopback interfaces for the subnets in NY, IL, and CA. Use point-to-point interfaces to connect
the remote branch offices to NY. See the sample network diagram below. Replace the phrase
“IP Address” by the correct IP address for each interface on the routers. Include the WAN IP
addresses on the diagram as well. (7 points)
First Major Deliverable in the Project: IP scheme for all three locations (fill in the IP tables
above) and the Visio Diagram.